pour une raison inconnue, il y avait un probleme de
stabilité d'OSPF entre le vss-6a-6k et le reseau
interne de RBX.
May 5 23:00:33 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from EXSTART to DOWN, Neighbor Down: Too many retransmissions
May 5 23:01:33 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from DOWN to DOWN, Neighbor Down: Ignore timer expired
May 5 23:03:43 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from EXSTART to DOWN, Neighbor Down: Too many retransmissions
May 5 23:04:43 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from DOWN to DOWN, Neighbor Down: Ignore timer expired
May 5 23:06:53 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from EXSTART to DOWN, Neighbor Down: Too many retransmissions
May 5 23:07:53 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from DOWN to DOWN, Neighbor Down: Ignore timer expired
May 5 23:10:02 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from EXSTART to DOWN, Neighbor Down: Too many retransmissions
May 5 23:11:02 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from DOWN to DOWN, Neighbor Down: Ignore timer expired
May 5 23:13:11 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr on Port-channel1 from EXSTART to DOWN, Neighbor Down: Too many retransmissions
nous avons coupé le port vers le reseau interne
et l'a remis en route. le probleme est fixé.
vss-6a-6k#conf t
Enter configuration commands, one per line. End with CNTL/Z.
vss-6a-6k(config)#inter po 1
vss-6a-6k(config-if)#shutdown
vss-6a-6k(config-if)#no shutdown