gra-g2-a9
Incident Report for Network & Infrastructure
Resolved
Nous avons des ECC Errors sur une des linecard de gra-g2-a9.

Nous avons contacter le contructeur.

LC/0/0/CPU0:May 9 10:46:09 CEST: prm_server_ty[297]: %PLATFORM-NP-3-ECC : prm_ser_check: Single-bit ECC error detected: NP 7, block 0xb (SRCH), offset 0, memid 30, name INSTRUCTION_MEM, addr 0x0000003e, bit 43, ext info 0xffffffff 0xffffffff 0xffffffff 0xffffffff, action 0 (Fix)
LC/0/0/CPU0:May 9 10:47:09 CEST: prm_server_ty[297]: %PLATFORM-NP-3-ECC : prm_ser_check: Single-bit ECC error detected: NP 7, block 0xb (SRCH), offset 0, memid 30, name INSTRUCTION_MEM, addr 0x0000003e, bit 43, ext info 0xffffffff 0xffffffff 0xffffffff 0xffffffff, action 0 (Fix)
LC/0/0/CPU0:May 9 10:48:09 CEST: prm_server_ty[297]: %PLATFORM-NP-3-ECC : prm_ser_check: Single-bit ECC error detected: NP 7, block 0xb (SRCH), offset 0, memid 30, name INSTRUCTION_MEM, addr 0x0000003e, bit 43, ext info 0xffffffff 0xffffffff 0xffffffff 0xffffffff, action 0 (Fix)
LC/0/0/CPU0:May 9 10:49:09 CEST: prm_server_ty[297]: %PLATFORM-NP-3-ECC : prm_ser_check: Single-bit ECC error detected: NP 7, block 0xb (SRCH), offset 0, memid 30, name INSTRUCTION_MEM, addr 0x0000003e, bit 43, ext info 0xffffffff 0xffffffff 0xffffffff 0xffffffff, action 0 (Fix)


Pas d'impact sur le trafic.



Update(s):

Date: 2014-05-09 09:10:38 UTC
Done.

Nous ne voyons plus les ECC Errors. Nous rétablissons le trafic et nous monitorons.

Date: 2014-05-09 08:51:42 UTC
Nous isolons le routeur et nous tentons de redémarrer la linecard
Posted May 09, 2014 - 08:49 UTC
This incident affected: Infrastructure || GRA (GRA1, GRA2, GRA3).