rbx3-104-n6-vrack & rbx3-105-n6-vrack
Scheduled Maintenance Report for Network & Infrastructure
Completed
Nous devons mettre ces 2 nexus Vrack a jour en 7.1.2 afin de supporter les 2348 (fex 48 port 10G-BASE T)
La maj sera fait lundi soir a partir de 22h.

Update(s):

Date: 2015-08-31 22:00:34 UTC
le 104 a fait un fail lors de la maj du fex 167 (le dernier)

Module 167: Non-disruptive upgrading.
FAIL. Return code 0x401D0039 (Disruptive image upgrade failed because mod
ule is not up).

Install has failed. Return code 0x40930020 (Non-disruptive upgrade of a m
odule failed).
Please identify the cause of the failure, and try 'install all' again.

L'upgrade s'est terminée donc avec du disruptif, sur fex 158, 161 et 167

Nous remontons le problème à Cisco pour suivi

Actuellement tout les fex sont up, et la conf est clean également.

Date: 2015-08-31 21:51:56 UTC
pour le 105, install hitless Okay
Module 165: Non-disruptive upgrading.
SUCCESS

Module 166: Non-disruptive upgrading.
SUCCESS

Module 167: Non-disruptive upgrading.
SUCCESS

Module 168: Non-disruptive upgrading.
SUCCESS

Module 169: Non-disruptive upgrading.
SUCCESS

Install has been successful.

rbx3-105-n6-vrack# sh fex
FEX FEX FEX FEX Fex
Number Description State Model Serial
------------------------------------------------------------------------
150 FEX150|45F01 Online N2K-C2248TP-E-1GE FOX1724GZLH
151 FEX151|45F02 Online N2K-C2248TP-E-1GE FOX1724GZ5N
152 FEX152|45F03 Online N2K-C2248TP-E-1GE FOX1724G9E1
153 FEX153|45F04 Online N2K-C2248TP-E-1GE FOX1724GZLC
154 FEX154|45F05 Online N2K-C2248TP-E-1GE FOX1724GZ5E
155 FEX155|45F06 Online N2K-C2248TP-E-1GE FOX1724GZLJ
156 FEX156|45F07 Online N2K-C2248TP-E-1GE SSI17160J5W
157 FEX157|45F08 Online N2K-C2248TP-E-1GE SSI17160D0C
158 FEX158|45F09 Online N2K-C2248TP-E-1GE SSI171708SA
159 FEX159|45F10 Online N2K-C2248TP-E-1GE FOX1724GPXN
160 FEX160|45F11 Online N2K-C2248TP-E-1GE SSI171708N1
161 FEX161|45F12 Online N2K-C2248TP-E-1GE SSI171708TB
162 FEX162|45F13 Online N2K-C2248TP-E-1GE SSI1615020P
163 FEX163|45F14 Online N2K-C2248TP-E-1GE FOX1724GZKH
164 FEX164|45F15 Online N2K-C2248TP-E-1GE FOX1724G9E9
165 FEX165|45F16 Online N2K-C2248TP-E-1GE FOX1724GZ5K
166 FEX166|BAIEFEX-166 Online N2K-C2248TP-E-1GE FOX1816G4MV
167 FEX167| Online N2K-C2248TP-E-1GE FOX1844G770
168 fex168| Online N2K-C2232TM-E-10GE SSI190301NV
169 FEX169| Online N2K-C2232TM-E-10GE SSI1849042P

Date: 2015-08-31 21:14:51 UTC
même chose pour le 104

Date: 2015-08-31 21:13:07 UTC
rbx3-105-n6-vrack# sh install all status
There is an on-going installation...
Enter Ctrl-C to go back to the prompt.

Continuing with installation process, please wait.
The login will be disabled until the installation is completed.

Performing supervisor state verification.
SUCCESS

Supervisor non-disruptive upgrade successful.

Pre-loading modules.

Date: 2015-08-31 21:07:42 UTC
105 en cours,

Do you want to continue with the installation (y/n)? [n] y

Install is in progress, please wait.

Performing runtime checks.
[####################] 100% -- SUCCESS

Notifying services about the upgrade.

Date: 2015-08-31 21:02:25 UTC
nous allons débuter la mise a jour des nexus.

Date: 2015-08-31 17:07:33 UTC
pour infos: on roll en hitless sur la nouvelle version:

rbx3-104-n6-vrack# sh install all impact kickstart n6000-uk9-kickstart.7.1.2.N1.1.bin system n6000-uk9.7.1.2.N1.1.bin

Verifying image bootflash:/n6000-uk9-kickstart.7.1.2.N1.1.bin for boot variable \"kickstart\".
[####################] 100% -- SUCCESS

Verifying image bootflash:/n6000-uk9.7.1.2.N1.1.bin for boot variable \"system\".
[####################] 100% -- SUCCESS

Verifying image type.
[####################] 100% -- SUCCESS

Extracting \"system\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"kickstart\" version from image bootflash:/n6000-uk9-kickstart.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"bios\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"fexth\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Performing module support checks.
[####################] 100% -- SUCCESS

Notifying services about system upgrade.
[####################] 100% -- SUCCESS



Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive rolling
150 yes non-disruptive rolling
151 yes non-disruptive rolling
152 yes non-disruptive rolling
153 yes non-disruptive rolling
154 yes non-disruptive rolling
155 yes non-disruptive rolling
156 yes non-disruptive rolling
157 yes non-disruptive rolling
158 yes non-disruptive rolling
159 yes non-disruptive rolling
160 yes non-disruptive rolling
161 yes non-disruptive rolling
162 yes non-disruptive rolling
163 yes non-disruptive rolling
164 yes non-disruptive rolling
165 yes non-disruptive rolling
166 yes non-disruptive rolling
167 yes non-disruptive rolling



Images will be upgraded according to following table:
Module Image Running-Version New-Version Upg-Required
------ ---------------- ---------------------- ---------------------- ------------
1 system 7.0(6)N1(1) 7.1(2)N1(1) yes
1 kickstart 7.0(6)N1(1) 7.1(2)N1(1) yes
1 bios v2.0.0(12/19/2014) v2.0.0(12/19/2014) no
1 power-seq v4.0 v4.0 no
1 fabric-power-seq v4.0 v4.0 no
2 power-seq v4.0 v4.0 no
150 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
151 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
152 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
153 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
154 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
155 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
156 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
157 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
158 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
159 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
160 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
161 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
162 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
163 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
164 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
165 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
166 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
167 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
1 microcontroller v1.0.0.1 v1.2.0.5 yes


rbx3-105-n6-vrack# sh install all impact kickstart n6000-uk9-kickstart.7.1.2.N1.1.bin system n6000-uk9.7.1.2.N1.1.bin

Verifying image bootflash:/n6000-uk9-kickstart.7.1.2.N1.1.bin for boot variable \"kickstart\".
[####################] 100% -- SUCCESS

Verifying image bootflash:/n6000-uk9.7.1.2.N1.1.bin for boot variable \"system\".
[####################] 100% -- SUCCESS

Verifying image type.
[####################] 100% -- SUCCESS

Extracting \"system\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"kickstart\" version from image bootflash:/n6000-uk9-kickstart.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"bios\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Extracting \"fexth\" version from image bootflash:/n6000-uk9.7.1.2.N1.1.bin.
[####################] 100% -- SUCCESS

Performing module support checks.
[####################] 100% -- SUCCESS

Notifying services about system upgrade.
[####################] 100% -- SUCCESS



Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive reset
2 yes non-disruptive rolling
150 yes non-disruptive rolling
151 yes non-disruptive rolling
152 yes non-disruptive rolling
153 yes non-disruptive rolling
154 yes non-disruptive rolling
155 yes non-disruptive rolling
156 yes non-disruptive rolling
157 yes non-disruptive rolling
158 yes non-disruptive rolling
159 yes non-disruptive rolling
160 yes non-disruptive rolling
161 yes non-disruptive rolling
162 yes non-disruptive rolling
163 yes non-disruptive rolling
164 yes non-disruptive rolling
165 yes non-disruptive rolling
166 yes non-disruptive rolling
167 yes non-disruptive rolling
168 yes non-disruptive rolling
169 yes non-disruptive rolling



Images will be upgraded according to following table:
Module Image Running-Version New-Version Upg-Required
------ ---------------- ---------------------- ---------------------- ------------
1 system 7.0(6)N1(1) 7.1(2)N1(1) yes
1 kickstart 7.0(6)N1(1) 7.1(2)N1(1) yes
1 bios v2.0.0(12/19/2014) v2.0.0(12/19/2014) no
1 power-seq v4.0 v4.0 no
1 fabric-power-seq v4.0 v4.0 no
2 power-seq v4.0 v4.0 no
150 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
151 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
152 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
153 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
154 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
155 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
156 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
157 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
158 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
159 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
160 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
161 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
162 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
163 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
164 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
165 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
166 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
167 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
168 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
169 fexth 7.0(6)N1(1) 7.1(2)N1(1) yes
1 microcontroller v1.0.0.1 v1.2.0.5 yes
Posted Aug 27, 2015 - 15:58 UTC
This scheduled maintenance affected: Infrastructure || RBX (RBX3).