Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
Date: 2016-02-14 11:13:07 UTC Confirmé, c'est bien l'uplink qui est mauvais.
Nous troubleshootons le lien
Date: 2016-02-14 10:55:23 UTC peut etre pas le port du nexus vers le fex finalement...
bhs4-16b-n56# sh int eth1/1 | i CRC
0 runts 0 giants 11466 CRC 0 no buffer
bhs4-16b-n56#
bhs4-16b-n56# sh int ethernet 1/1 transceiver details
Ethernet1/1
transceiver is present
type is 10Gbase-LR
name is AGILESTAR
part number is SFP-10G-LR+-AS
revision is JL
serial number is ANHJOHNOPD1248
nominal bitrate is 10300 MBit/sec
Link length supported for 9/125um fiber is 10 km
cisco id is --
cisco extended id number is 4
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 27.28 C 88.00 C -13.00 C 85.00 C -8.00 C
Voltage 3.29 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 34.91 mA 85.00 mA 15.00 mA 80.00 mA 20.00 mA
Tx Power -1.92 dBm 1.99 dBm -8.01 dBm 0.99 dBm -7.01 dBm
Rx Power -16.98 dBm 2.49 dBm -20.00 dBm 1.99 dBm -18.23 dBm
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Nous investiguons toujours, en tout cas, ce lien a des niveau trop bas
nous allons upper le port vers le fex et isole l'uplink
Date: 2016-02-14 10:33:26 UTC nous avons de l'output error sur l'un des 2 liens
bhs4-16b-n56# sh int et1/3 | i CRC|error
0 runts 0 giants 146862 CRC 0 no buffer
146862 input error 0 short frame 0 overrun 0 underrun 0 ignored
6981947 output error 0 collision 0 deferred 0 late collision
bhs4-16b-n56# clear counters interface port-channel 100
bhs4-16b-n56# sh int et1/3 | i CRC|error
0 runts 0 giants 0 CRC 0 no buffer
0 input error 0 short frame 0 overrun 0 underrun 0 ignored
0 output error 0 collision 0 deferred 0 late collision
bhs4-16b-n56# sh int et1/3 | i CRC|error
0 runts 0 giants 0 CRC 0 no buffer
0 input error 0 short frame 0 overrun 0 underrun 0 ignored
16 output error 0 collision 0 deferred 0 late collision
Nous avons shut le port pour troubleshoot, plus de loss depuis
Posted Feb 14, 2016 - 10:19 UTC
This incident affected: Infrastructure || BHS (BHS4).