FS#21929 — Milano, IT

Attached to Project— Network and racks
Amélioration
Backbone EU
CLOSED
100%
Nos 6k de Milan mil-5-6k et mil-1-6k vont être remplacés la semaine prochaine par un ASR 9904 afin d'augmenter progressivement la capacité de ce POP, d'abord à 300G puis à 480G dans les mois à venir.

Les techniciens seront sur place pour préparer l'intervention Mardi 13/12.

Le remplacement aura lieu le Mercredi 14/12 à partir de 6h00 GMT+2.


Date:  Wednesday, 14 December 2016, 11:28AM
Reason for closing:  Done
Additional comments about closing:  Tout est désormais, clean et migré. La weathermap est à jour.
Comment by OVH - Tuesday, 13 December 2016, 16:38PM

Tous les ports ASR <> a72 sont up !

Te0/0/0/0 up up I:mil-5-a72:OVH:Eth1:BE100
Te0/0/0/1 up up I:mil-5-a72:OVH:Eth2:BE100
Te0/0/0/2 up up I:mil-5-a72:OVH:Eth3:BE100
Te0/0/0/3 up up I:mil-5-a72:OVH:Eth4:BE100
Te0/0/0/4 up up I:mil-5-a72:OVH:Eth5:BE100
Te0/0/0/5 up up I:mil-5-a72:OVH:Eth6:BE100
Te0/0/0/6 up up I:mil-5-a72:OVH:Eth7:BE100
Te0/0/0/7 up up I:mil-5-a72:OVH:Eth8:BE100
Te0/0/0/8 up up I:mil-5-a72:OVH:Eth9:BE100
Te0/0/0/9 up up I:mil-5-a72:OVH:Eth10:BE100
Te0/0/0/10 up up I:mil-5-a72:OVH:Eth11:BE100
Te0/0/0/11 up up I:mil-5-a72:OVH:Eth12:BE100
Te0/0/0/12 up up I:mil-5-a72:OVH:Eth13:BE100
Te0/0/0/13 up up I:mil-5-a72:OVH:Eth14:BE100
Te0/0/0/14 up up I:mil-5-a72:OVH:Eth15:BE100
Te0/0/0/15 up up I:mil-5-a72:OVH:Eth16:BE100
Te0/0/0/16 up up I:mil-5-a72:OVH:Eth17:BE100
Te0/0/0/17 up up I:mil-5-a72:OVH:Eth18:BE100
Te0/0/0/18 up up I:mil-5-a72:OVH:Eth19:BE100
Te0/0/0/19 up up I:mil-5-a72:OVH:Eth20:BE100
Te0/0/0/20 up up I:mil-5-a72:OVH:Eth21:BE100
Te0/0/0/21 up up I:mil-5-a72:OVH:Eth22:BE100
Te0/0/0/22 up up I:mil-5-a72:OVH:Eth23:BE100
Te0/0/0/23 up up I:mil-5-a72:OVH:Eth24:BE100
Te0/1/0/0 up up I:mil-5-a72:OVH:Eth25:BE100
Te0/1/0/1 up up I:mil-5-a72:OVH:Eth26:BE100
Te0/1/0/2 up up I:mil-5-a72:OVH:Eth27:BE100
Te0/1/0/3 up up I:mil-5-a72:OVH:Eth28:BE100
Te0/1/0/4 up up I:mil-5-a72:OVH:Eth29:BE100
Te0/1/0/5 up up I:mil-5-a72:OVH:Eth30:BE100
Te0/1/0/6 up up I:mil-5-a72:OVH:Eth31:BE100
Te0/1/0/7 up up I:mil-5-a72:OVH:Eth32:BE100
Te0/1/0/8 up up I:mil-5-a72:OVH:Eth33:BE100
Te0/1/0/9 up up I:mil-5-a72:OVH:Eth34:BE100
Te0/1/0/10 up up I:mil-5-a72:OVH:Eth35:BE100
Te0/1/0/11 up up I:mil-5-a72:OVH:Eth36:BE100
Te0/1/0/12 up up I:mil-5-a72:OVH:Eth37:BE100
Te0/1/0/13 up up I:mil-5-a72:OVH:Eth38:BE100
Te0/1/0/14 up up I:mil-5-a72:OVH:Eth39:BE100
Te0/1/0/15 up up I:mil-5-a72:OVH:Eth40:BE100
Te0/1/0/16 up up I:mil-5-a72:OVH:Eth41:BE100
Te0/1/0/17 up up I:mil-5-a72:OVH:Eth42:BE100
Te0/1/0/18 up up I:mil-5-a72:OVH:Eth43:BE100
Te0/1/0/19 up up I:mil-5-a72:OVH:Eth44:BE100
Te0/1/0/20 up up I:mil-5-a72:OVH:Eth45:BE100
Te0/1/0/21 up up I:mil-5-a72:OVH:Eth46:BE100
Te0/1/0/22 up up I:mil-5-a72:OVH:Eth47:BE100
Te0/1/0/23 up up I:mil-5-a72:OVH:Eth48:BE100


Nous validons les derniers détails de l'opération.


Comment by OVH - Tuesday, 13 December 2016, 18:40PM

Nous sommes prêt pour l'intervention demain matin. Les sessions seront isolées vers 5h30 pour un démarrage de l'opération à 6h00.


Comment by OVH - Wednesday, 14 December 2016, 05:18AM

Nous isolons mil-1-6k et mil-5-6k afin de procéder à leur remplacement.


Comment by OVH - Wednesday, 14 December 2016, 06:49AM

mil-5-a9 est up, nous travaillons à faire remonter la voip et lancons la mise à jour de mil-5-n7 en parallèle.


Comment by OVH - Wednesday, 14 December 2016, 07:30AM

La VOIP est toujours les ports passent en suspended, nous investiguons.


Comment by OVH - Wednesday, 14 December 2016, 07:38AM

La VOIP est de nouveau up, les ports n'étaient pas shut sur l'ancien routeur, ce qui provoquait un problème lorsque le port-channel montait.

Nous mettons à jour les EPLD sur mil-5-n7 et remettons en service le POP.


Comment by OVH - Wednesday, 14 December 2016, 08:33AM

Nous avons une carte en EPLD failed, nous investiguons et tentons un reseat de la carte.


Comment by OVH - Wednesday, 14 December 2016, 09:06AM

Nous avons réussi à mettre à jour la carte après un reseat. Nous avons modifié les configurations OSPF pour être standard.

Nous rallumons MIX.


Comment by OVH - Wednesday, 14 December 2016, 10:10AM

L'opération est terminée, nous avons cleaner les vlans inutilisés sur l'ASR et le n7..