FS#23664 — AMSIX, AMS, NL

Attached to Project— Reseau Internet et Baies
Amélioration
Backbone EU
CLOSED
100%
Nous allons upgrader sous peu notre capacité vers AMSIX à Amsterdam. Nous allons ajouter 1x100G à chaque bundle existant de 2x100G, pour passer à une capacité totale de 600G sur ce point d'échange.
Date:  Tuesday, 14 March 2017, 16:47PM
Reason for closing:  Done
Additional comments about closing:  Nous continuons de contrôler mais l'upgrade à 600G de capacité est ok.
Comment by OVH - Tuesday, 14 March 2017, 15:42PM

[16:38:38] ams-5-n7 => Interface port-channel154,bandwidth changed to 300000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)

ams-5-n7# sh int eth 5/3 | i rate|CRC
30 seconds input rate 44621661408 bits/sec, 6485558 packets/sec
30 seconds output rate 36014869104 bits/sec, 4279819 packets/sec
input rate 44.62 Gbps, 6.49 Mpps; output rate 36.01 Gbps, 4.28 Mpps
300 seconds input rate 31653469008 bits/sec, 4575045 packets/sec
300 seconds output rate 25337873120 bits/sec, 3031933 packets/sec
input rate 31.65 Gbps, 4.57 Mpps; output rate 25.34 Gbps, 3.03 Mpps
0 runts 0 giants 0 CRC/FCS 0 no buffer


Nous avons désormais 300G de capacité sur ams-5-n7/a9

Nous continuons sur ams-1-n7/a9


Comment by OVH - Tuesday, 14 March 2017, 16:03PM

[16:58:58] ams-1-n7 => Interface port-channel105,bandwidth changed to 300000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)

ams-1-n7# sh int eth 5/3 | i rate|CRC
30 seconds input rate 16412582816 bits/sec, 2305295 packets/sec
30 seconds output rate 37734840384 bits/sec, 4630409 packets/sec
input rate 16.41 Gbps, 2.31 Mpps; output rate 37.73 Gbps, 4.63 Mpps
300 seconds input rate 12972553752 bits/sec, 1820402 packets/sec
300 seconds output rate 29822891352 bits/sec, 3664955 packets/sec
input rate 12.97 Gbps, 1.82 Mpps; output rate 29.82 Gbps, 3.66 Mpps
0 runts 0 giants 0 CRC/FCS 0 no buffer


Nous avons désormais 2x 300G de capacité sur AMSIX.