FS#24830 — CHI <> ASH

Attached to Project— Reseau Internet et Baies
Amélioration
Backbone US
CLOSED
100%
Nous passons la capacité Chicago <> Ashburn de 2x1x100G à 2x2x100G, soit 400G entre les 2 POPs.
Date:  Thursday, 18 May 2017, 21:31PM
Reason for closing:  Done
Additional comments about closing:  Tout est ok, nous avons désormais 400G de capacité entre Ashburn et Chicago
Comment by OVH - Thursday, 18 May 2017, 19:46PM

Le lien entre chi-1-n7 et ash-1-n7 est désormais de 2x100G

[19:42:27] ash-1-n7 => port-channel1316: Ethernet9/6 is up (%ETH_PORT_CHANNEL-5-PORT_UP)
[19:42:27] chi-1-n7 => port-channel1316: Ethernet5/7 is up (%ETH_PORT_CHANNEL-5-PORT_UP)
[19:42:28] ash-1-n7 => Interface Ethernet9/6, vlan 1316 up (%ETHPORT-5-IF_TRUNK_UP)
[19:42:28] ash-1-n7 => Interface port-channel1316,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)
[19:42:28] ash-1-n7 => Interface Ethernet9/6 is up in mode trunk (%ETHPORT-5-IF_UP)
[19:42:28] chi-1-n7 => Interface Ethernet5/7, vlan 1316 up (%ETHPORT-5-IF_TRUNK_UP)
[19:42:28] chi-1-n7 => Interface port-channel1316,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)
[19:42:28] chi-1-n7 => Interface Ethernet5/7 is up in mode trunk (%ETHPORT-5-IF_UP)

Pas de CRC constatés, nous continuons l'upgrade entre chi-5-n7 et ash-5-n7


Comment by OVH - Thursday, 18 May 2017, 19:58PM

Le lien entre chi-5-n7 et ash-1-n7 est proddé. Nous avons du appliquer une modification sur la configuration non standard du port-channel qui a fait flappé l'ensemble du port-channel et les sessions OSPF / BFD.

[19:52:03] chi-5-n7 => Interface Ethernet6/5 is up in mode trunk (%ETHPORT-5-IF_UP)
[19:52:03] ash-5-n7 => Interface port-channel1317, vlan 1317 up (%ETHPORT-5-IF_TRUNK_UP)
[19:52:03] ash-5-n7 => Interface Ethernet9/6, vlan 1317 up (%ETHPORT-5-IF_TRUNK_UP)
[19:52:03] ash-5-n7 => Interface port-channel1317,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)
[19:52:03] ash-5-n7 => Interface Ethernet9/6 is up in mode trunk (%ETHPORT-5-IF_UP)
[19:52:03] chi-5-n7 => Interface port-channel1317, vlan 1317 up (%ETHPORT-5-IF_TRUNK_UP)
[19:52:03] chi-5-n7 => Interface Ethernet5/7, vlan 1317 up (%ETHPORT-5-IF_TRUNK_UP)
[19:52:03] chi-5-n7 => Interface port-channel1317,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)
[19:52:03] chi-5-n7 => Interface Ethernet5/7 is up in mode trunk (%ETHPORT-5-IF_UP)
[19:52:03] chi-5-n7 => Interface Ethernet5/7 is up in mode trunk (%ETHPORT-5-IF_UP)

Nous contrôlons que tout revient à la normale.