OVHcloud Web Hosting Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
Réseau Lyon
Incident Report for Web Cloud
Resolved
Nous constatons des problemes de routage sur la zone de Lyon.

Update(s):

Date: 2017-07-18 15:17:52 UTC
L'OSPF avec les routeurs backbone a flappé.

Les IPs sont de nouveau UP.

Date: 2017-07-18 15:16:18 UTC
Jul 18 16:02:05 lns-1-lyo : [0006]: %OSPF-6-INFO: OSPF-16276: Full neighbor 151.80.228.10 event: Inactivity Timer
Jul 18 16:02:05 lns-1-lyo : [0006]: %OSPF-6-INFO: OSPF-16276: Neighbor 151.80.228.10 fell from Full state to Down state
Jul 18 16:02:13 lns-1-lyo : [0002]: %OSPF-6-INFO: OSPF-16276: Full neighbor 178.32.37.174 event: Inactivity Timer
Jul 18 16:02:13 lns-1-lyo : [0002]: %OSPF-6-INFO: OSPF-16276: Neighbor 178.32.37.174 fell from Full state to Down state
Jul 18 16:02:14 lns-1-lyo : [0003]: %OSPF-6-INFO: OSPF-16276: Full neighbor 178.32.37.172 event: Inactivity Timer
Jul 18 16:02:14 lns-1-lyo : [0003]: %OSPF-6-INFO: OSPF-16276: Neighbor 178.32.37.172 fell from Full state to Down state
Jul 18 16:02:38 lns-1-lyo : [0003]: %OSPF-6-INFO: OSPF-16276: Full neighbor 178.32.37.170 event: Inactivity Timer
Jul 18 16:02:38 lns-1-lyo : [0003]: %OSPF-6-INFO: OSPF-16276: Neighbor 178.32.37.170 fell from Full state to Down state
Posted Jul 18, 2017 - 15:06 UTC
This incident affected: Internet Access || FTTH.