Nous mettons en production un des 100G entre Palo Alto ca, us et San José, ca, us.
Update(s):
Date: 2017-08-22 15:59:53 UTC
Everything is fine :
1 runts 0 giants 0 CRC/FCS 0 no buffer
pao-sv8-bb1-n7# sh int eth 5/4, eth 6/4 | i rate|CRC
30 seconds input rate 1685224128 bits/sec, 722603 packets/sec
30 seconds output rate 6909798952 bits/sec, 706949 packets/sec
input rate 1.68 Gbps, 722.60 Kpps; output rate 6.91 Gbps, 706.95 Kpps
300 seconds input rate 1639412736 bits/sec, 717278 packets/sec
300 seconds output rate 6593680896 bits/sec, 678281 packets/sec
input rate 1.64 Gbps, 717.28 Kpps; output rate 6.59 Gbps, 678.28 Kpps
20 runts 0 giants 1 CRC/FCS 0 no buffer
30 seconds input rate 1698665136 bits/sec, 686201 packets/sec
30 seconds output rate 6424341120 bits/sec, 657263 packets/sec
input rate 1.70 Gbps, 686.20 Kpps; output rate 6.42 Gbps, 657.26 Kpps
300 seconds input rate 1576293408 bits/sec, 683480 packets/sec
300 seconds output rate 6475647712 bits/sec, 657591 packets/sec
input rate 1.58 Gbps, 683.48 Kpps; output rate 6.47 Gbps, 657.59 Kpps
1 runts 0 giants 0 CRC/FCS 0 no buffer
Date: 2017-08-22 15:35:38 UTC
Nous venons de prodder le deuxième 100G manquant.
[17:35:15] sjo-sv5-bb1-n7 => Interface port-channel1368,bandwidth changed to 200000000 Kbit (%ETHPORT-5-IF_BANDWIDTH_CHANGE)
Date: 2017-08-02 13:41:20 UTC
Les anciens 4x10G ont été cleanés. Il nous reste à activer le dernier 100G pour finir la boucle.
Date: 2017-08-02 09:36:48 UTC
Nous attendons les informations concernant le deuxième circuit 100G.
Date: 2017-07-28 11:09:10 UTC
Le lien est proddé après clean des chemins
sjo-sv5-bb1-n7# sh int po 1368 | i rate|CRC
30 seconds input rate 14226948328 bits/sec, 1464867 packets/sec
30 seconds output rate 2615141312 bits/sec, 1116712 packets/sec
input rate 14.23 Gbps, 1.46 Mpps; output rate 2.62 Gbps, 1.12 Mpps
300 seconds input rate 14121489536 bits/sec, 1457195 packets/sec
300 seconds output rate 2529582800 bits/sec, 1107443 packets/sec
input rate 14.12 Gbps, 1.46 Mpps; output rate 2.53 Gbps, 1.11 Mpps
0 runts 0 giants 0 CRC/FCS 0 no buffer
pao-sv8-bb1-n7# sh int po 1368 | i rate|CRC
30 seconds input rate 2392630384 bits/sec, 1097986 packets/sec
30 seconds output rate 14286651824 bits/sec, 1471589 packets/sec
input rate 2.39 Gbps, 1.10 Mpps; output rate 14.29 Gbps, 1.47 Mpps
300 seconds input rate 2511937944 bits/sec, 1105514 packets/sec
300 seconds output rate 14132324416 bits/sec, 1458314 packets/sec
input rate 2.51 Gbps, 1.11 Mpps; output rate 14.13 Gbps, 1.46 Mpps
0 runts 0 giants 0 CRC/FCS 0 no buffer
Nous cleanerons les 4x10G à partir de lundi et nous ajouterons le deuxième 100G la semaine prochaine normalement.
Date: 2017-07-28 08:53:23 UTC
Nous avons mis en production mais rollback tout de suite, suite à une augmentation importante du nombre de CRC. Nous investiguons avec les fournisseurs.
Posted Jul 28, 2017 - 08:32 UTC