FS#26501 — TOR <> NWK

Attached to Project— Reseau Internet et Baies
Maintenance
Backbone US
CLOSED
100%
Nous isolons le lien 100G entre Newark et Toronto afin de remplacer une optique sur tor-1-a72.
Date:  Thursday, 10 August 2017, 06:48AM
Reason for closing:  Done
Additional comments about closing:  Tout est ok
Comment by OVH - Tuesday, 08 August 2017, 18:19PM

Nous avons remis en production et nous ne constatons plus de CRC

tor-1-a72#sh int eth 52/1 | i rate|CRC
30 seconds input rate 7.48 Gbps (7.6% with framing overhead), 829149 packets/sec
30 seconds output rate 972 Mbps (1.0% with framing overhead), 438363 packets/sec
0 input errors, 0 CRC, 0 alignment, 0 symbol, 0 input discards

nwk-5-n7# sh int po 1002 | i rate|CRC
30 seconds input rate 956539016 bits/sec, 438014 packets/sec
30 seconds output rate 7427828512 bits/sec, 810939 packets/sec
input rate 956.54 Mbps, 438.01 Kpps; output rate 7.43 Gbps, 810.94 Kpps
300 seconds input rate 983710656 bits/sec, 434252 packets/sec
300 seconds output rate 7495699256 bits/sec, 823261 packets/sec
input rate 983.71 Mbps, 434.25 Kpps; output rate 7.49 Gbps, 823.26 Kpps
0 runts 0 giants 0 CRC/FCS 0 no buffer


Nous monitorons.