rssLink RSS for all categories
 
icon_orange
icon_green
icon_orange
icon_red
icon_red
icon_green
icon_green
icon_red
icon_red
icon_orange
icon_green
icon_green
icon_green
icon_orange
icon_orange
icon_green
icon_green
icon_green
icon_red
icon_green
icon_green
icon_blue
icon_red
icon_blue
icon_orange
icon_green
icon_green
icon_green
icon_green
icon_green
icon_green
icon_green
 

FS#29896 — RETN, AS9002, Warsaw, PL

Attached to Project— Reseau Internet et Baies
Amélioration
Backbone EU
CLOSED
100%
Nous mettons en production un nouveau PNI 100G avec RETN afin de remplacer les 4x10G existants.

Aucun impact n'est prévu, le trafic va basculer automatiquement des 40G au 100G.
Date:  Wednesday, 14 February 2018, 10:44AM
Reason for closing:  Done
Comment by OVH - Tuesday, 13 February 2018, 13:36PM

Le PNI est migré sur le 100G nous contrôlons et monitorons.

port-channel160 is up
30 seconds input rate 1723436912 bits/sec, 1096728 packets/sec
30 seconds output rate 27279640280 bits/sec, 3778689 packets/sec
input rate 1.72 Gbps, 1.10 Mpps; output rate 27.28 Gbps, 3.78 Mpps
300 seconds input rate 1518807856 bits/sec, 706385 packets/sec
300 seconds output rate 23140493296 bits/sec, 3124223 packets/sec
input rate 1.52 Gbps, 706.39 Kpps; output rate 23.14 Gbps, 3.12 Mpps
0 runts 0 giants 0 CRC/FCS 0 no buffer


Comment by OVH - Wednesday, 14 February 2018, 10:12AM

Nous éteignons les 4 ports 10G