OVHcloud Public Cloud Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
Object Storage SBG
Incident Report for Public Cloud
Resolved
We are observing degraded latencies, we are investigating

Update(s):

Date: 2018-02-22 16:51:20 UTC
operation finished, the cluster is stabilized, we will add more hardware in the next days

Date: 2018-02-22 15:49:00 UTC
new rebalance in progress

Date: 2018-02-21 15:32:36 UTC
we are starting a new rebalance operation

Date: 2018-02-20 18:35:39 UTC
the replication method change wasn't applied correctly, we forced a swift-object-replicator restart. Latencies should decrease now

Date: 2018-02-20 16:02:11 UTC
replication method switched from rsync to ssync

Date: 2018-02-20 15:41:59 UTC
The rebalance is showing its first effects : increased latencies while errors on PUT requests are decreasing. We will switch back replication method to ssync as soon as possible to lower the latencies

Date: 2018-02-20 14:56:17 UTC
rebalance in progress

Date: 2018-02-20 13:55:55 UTC
We are adding storage nodes to the cluster, a rebalance will follow

Date: 2018-02-19 16:59:36 UTC
Due to high dispersion on objects placement we had to switch the replication method from ssync to rsync, which affects performance. Once the dispersion rate reaches an acceptable value we will switch back replication method to ssync
Posted Feb 19, 2018 - 08:31 UTC