FS#31834 — rbx-gre1a-a72

Attached to Project— Reseau Internet et Baies
Incident
Roubaix
CLOSED
100%
Nous constatons un loss d'environ 1% sur certaine source/destination sur ce switch. Le problème semble très très isolé. Nous investiguons.

---

We saw around 1% loss on specific source/destination trough this switch. The issue seem to be very isolated, we are currently investigating.

Date:  Sunday, 27 May 2018, 05:57AM
Reason for closing:  Done
Comment by OVH - Saturday, 26 May 2018, 16:04PM

Nous isolons rbx-gre1a-a72 <> par1-p19-gre1a/b-a72.

Le traffic sera repris par rbx-gre1b-a72.

--

We isolate rbx-gre1a-a72 <> par1-p19-gre1a/b-a72.

The traffic will be taken by rbx-gre1b-a72


Comment by OVH - Saturday, 26 May 2018, 16:12PM

Nous isolons rbx-gre1a-a72 <> waw-gre1a/b-a72.

Le traffic sera repris par rbx-gre1b-a72.

--

We isolate rbx-gre1a-a72 <> waw-gre1a/b-a72.

The traffic will be taken by rbx-gre1b-a72


Comment by OVH - Saturday, 26 May 2018, 16:14PM

Nous contactons le constructeur en parallèle


--

We contact the manufacturer


Comment by OVH - Saturday, 26 May 2018, 17:06PM

Nous constatons une saturation sur le B, nous allons ajouter de la capacité en urgence. Nous ne constatons plus de loss depuis les isolations.

We see saturation on B, we will add capacity urgently. We don't see more loss since isolation.


Comment by OVH - Saturday, 26 May 2018, 17:08PM

We think the bug is 181627:
On the DCS-7500R and DCS-7280R series, packets buffered in external DRAM may intermittently experience corruption which can cause those packets to be dropped.

Awaiting Arista confirmation.


Comment by OVH - Saturday, 26 May 2018, 20:33PM

La capacité a été ajoutée. Il n'y a plus d'impact. Nous attendons encore Arista.

Capacity has been upgraded and we don't have any issue right now. Awaiting Arista confirmation again.


Comment by OVH - Sunday, 27 May 2018, 04:48AM

Nous isolons SGP/SYD/LIM/ERI/VIN/HB de rbx-gre1a-a72.

We isolate SGP/SYD/LIM/ERI/VIN/HB from rbx-gre1a-a72


Comment by OVH - Sunday, 27 May 2018, 05:08AM

Nous mettons à jours rbx-gre1a-a72 pour fixer le bug.

--

We will update rbx-gre1a-a72 to fix the bug.


Comment by OVH - Sunday, 27 May 2018, 05:20AM

On remet en production rbx-gre1a-a72.

-

We will put back in production rbx-gre1a-a72.


Comment by OVH - Sunday, 27 May 2018, 05:34AM

rbx-gre1a-a72 est revenu en production. Nous allons monitorer la situation 30 minutes avant de fermer la task.
--
rbx-gre1a-a72 is back to production. We will monitor the situation 30 minutes before closing this task.


Comment by OVH - Sunday, 27 May 2018, 05:57AM

La situation est normale et stable. Nous fermons cette task maintenant.

--

The situation is normal and stable, we will close this task now.