FS#32089 — rbx-g1-nc5 | rbx-g2-nc5

Attached to Project— Reseau Internet et Baies
Maintenance planifie
Roubaix
CLOSED
100%
Nous allons upgrader le couple de routeur rbx-g1-nc5 | rbx-g2-nc5 dans le dernière version préconisée par notre fournisseur.
Pas d'impact prévu lors de l'upgrade.

Début de la maintenance : 19 juin 00:00 UTC+2
Fin de la maintenance : 19 juin 06:00 UTC+2

----

We are going to upgrade this router couple rbx-g1-nc5 | rbx-g2-nc5 in the last version has advised by the manufacturer.

Start of the maintenance : June 19 00:00 UTC+2
End of the maintenance : June 19 06:00 UTC+2
Date:  Wednesday, 20 June 2018, 14:30PM
Reason for closing:  Done
Comment by OVH - Monday, 18 June 2018, 23:41PM

Cette maintenance a été remis au 20 Juin 2018 entre 00h00 UTC+2 et 06h00 UTC+2.

--

This maintenance has been post-poned on 20th June 2018 between 00h00 UTC+2 and 06h00 UTC+2


Comment by OVH - Wednesday, 20 June 2018, 00:59AM

Nous débutons la maintenance avec un changement de configuration BGP sur rbx-d1/d2-a75.


Comment by OVH - Wednesday, 20 June 2018, 01:28AM

We just lost 4k IP on rbx-s5/s6-6k (PCC) due the a neighbor peer-group migration. We rolled back the configuration, the traffic is now back online on both router. We will investigate the root cause.


Comment by OVH - Wednesday, 20 June 2018, 01:51AM

Nous devons analyser la root cause avant de continuer. Nous allons donc remettre la mise-à-jours à demain soir 21 Juin 2018 entre 00h00 et 06h00 UTC+2.

--

We need to analyse the root cause before continue. We will post-pone the update on tomorrow 21st June 2018 between 00h00 and 06h00 UTC+2.


Comment by OVH - Wednesday, 20 June 2018, 02:32AM

Nous avons identifié la root cause. Un paramètre manquant sur le peer-group BGP de destination de rbx-s5/s6-6k est la cause.

--

We identified the root cause. A missing configuration on the destination BGP peer-group of rbx-s5/s6-6k is the cause. We will continue to regularize the BGP configuration on rbx-d1/d2-a75.


Comment by OVH - Wednesday, 20 June 2018, 04:11AM

Nous avons eu une instabilité de 2 minute sur IPv6 sur certain concentrateur. Tout est revenu à la normale.

Nous avons terminée de régulariser la configuration de rbx-d1/d2-a75.

--

We got a 2 minutes instability on IPv6 of few concentrator. Everything is back to normal.

We have finished to regulate the configuration of rbx-d1/d2-a75.


Comment by OVH - Wednesday, 20 June 2018, 14:30PM

Nous allons remettre cette maintenance à la semaine prochaine.

--

We will post-pone this maintenance on the next week.