rssLink RSS for all categories
 
icon_orange
icon_green
icon_green
icon_orange
icon_red
icon_green
icon_green
icon_red
icon_red
icon_orange
icon_green
icon_green
icon_green
icon_blue
icon_orange
icon_orange
icon_blue
icon_green
icon_orange
icon_orange
icon_green
icon_orange
icon_red
icon_red
icon_orange
icon_green
icon_green
icon_green
icon_green
icon_green
icon_green
icon_green
 

FS#32277 — vss-4-6k

Attached to Project— Reseau Internet et Baies
Incident
Roubaix   → RBX-4
CLOSED
100%
Nous avons identifié un problème sur la linecard 7 du vss-4-6k nous allons bacuslé tout le traffic impacté sur le vss-4b-6k

----

We have identified a problem on the linecard 7 on vss-4b-6k we will swap all impacted traffic on vss-4b-6k
Date:  Tuesday, 19 June 2018, 17:50PM
Reason for closing:  Done
Additional comments about closing:  configuration glbp réappliquée
Comment by OVH - Friday, 15 June 2018, 18:09PM

L'ensemble du trafic a été déplacé sur le routeur vss-4b-6k. La linecard 7 du vss-4-6k ne gère plus de trafic.


------

The linecard 7 of vss-4-6k is now isolated and all traffic is going through vss-4b-6k.


Comment by OVH - Tuesday, 19 June 2018, 17:12PM

Les macs GLBP ne sont pas synchronisées entre les linecards, nous devons réappliquer la configuration GLBP sur le réseau 188.165.243.0/24 sur le routeur A. Le trafic passant par le côté B il n'y a donc pas d'impact à prévoir