Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
Maintenances are planned on the following equipments in order to proceed to a version upgrade.
No impact is expected. Only connected sessions will have to be reestablished during the flap between the first and second switch
bhs-iplb1/2-a70 : June, 25th, between 00:09 & 11:00am FR Time (Done)
waw1-sd2a/b-n9 : June, 26th, between 09:00 & 11:00am FR Time (Done)
sbg2-sd6a/b-n9 : June, 27th, between 09:00 & 11:00am FR Time (Done)
sbg2-sd5a/b-n9 : June, 28th, between 09:00 & 11:00am FR Time (Done)
gra1-sdagg1a/b-n9 : July, 4, between 03:00 & 06:00am FR Time (Done)
rbx6-sd1a/b-n9 : July, 5th, between 00:00 & 06:00am FR Time (Done)
gra1-sd4a/b-n9 : July, 16th, between 00:00 & 06:00am FR Time (Done)
gra-iplb1/2-a70 : July, 24th, between 00:00 & 06:00am FR Time (Done)
rbx6-sdagg1a/b-a72 : July, 25th, between 00:00 & 06:00am FR Time (Done)
rbx-iplb1/2-a70 : July, 31th, between 00:00 & 06:00am FR Time (Done)
rbx-iplb3/4-a70 : August, 2nd, between 00:00 & 06:00am FR Time (Done)
gra-iplb3/4-a70 : August, 8th, between 00:00 & 06:00am FR Time (Done)
Update(s):
Date: 2018-12-20 02:07:17 UTC sbg-iplb1/2-a70 is now up-to-date and so every switches are done
Date: 2018-12-20 01:32:11 UTC all traffic is going through sbg-iplb1-a70, we are upgrading sbg-iplb2-a70
Date: 2018-12-20 01:08:53 UTC sbg-iplb1-a70 is up-to-date , we are going to isolate sbg-iplb2-a70
Date: 2018-12-19 23:49:51 UTC sbg-iplb1-a70 is isolated, all traffic is going through sbg-iplb2-a70
Date: 2018-12-19 23:11:23 UTC We start working on the maintenance. We are starting with sbg-iplb1-a70 and then we will do sbg-iplb2-a70
Date: 2018-10-01 22:58:12 UTC We cancel and postpone the maintenance on sbg-iplb1/2-a70. / Nous allons annuler et remettre la maintenance de sbg-iplb1/2-a70.
Date: 2018-10-01 22:04:03 UTC we will start maintenance on sbg-iplb1-a70 / nous débutons la maintenance sur sbg-iplb1-a70
Date: 2018-08-07 23:49:51 UTC gra-iplb4-a70 a été upgradé avec succes
Date: 2018-08-07 23:23:02 UTC Nous upgradons le gra-iplb4-a70
Date: 2018-08-07 01:29:54 UTC Nous avons du faire une rollback sur le couple sbg-iplb1/2-a70
Nous re-planifions la maintenance
Date: 2018-08-06 23:40:56 UTC sbg-iplb1-a70 is updated
Date: 2018-08-06 22:27:30 UTC
Nous avons commencé la mise à jour sur sbg-iplb1-a70
--
We've started the upgrade on sbg-iplb1-a70
Date: 2018-08-02 00:26:04 UTC Mise à jour terminée sur rbx-iplb4-a70. Le trafic devrait maintenant être normal et stable.
--
Upgrade completed on rbx-iplb4-a70. Traffic should now be restored and stable.
Date: 2018-08-01 23:41:33 UTC Mise à niveau terminée sur rbx-iplb3-a70 maintenant en cours de démarrage rbx-iplb4-a70.
--
Completed upgrade on rbx-iplb3-a70 now starting rbx-iplb4-a70.
Date: 2018-08-01 23:12:43 UTC Nous avons commencé la mise à jour sur rbx-iplb3-a70
--
We've started the upgrade on rbx-iplb3-a70
Date: 2018-07-30 23:06:12 UTC Mise à jour terminée sur rbx-iplb2-a70. Le trafic devrait maintenant être normal et stable.
--
Upgrade completed on rbx-iplb2-a70. Traffic should now be restored and stable.
Date: 2018-07-30 22:41:07 UTC Mise à niveau terminée sur rbx-iplb1-a70 maintenant en cours de démarrage rbx-iplb2-a70.
--
Completed upgrade on rbx-iplb1-a70 now starting rbx-iplb2-a70.
Date: 2018-07-30 22:08:31 UTC Nous avons commencé la mise à jour sur rbx-iplb1-a70
--
We've started the upgrade on rbx-iplb1-a70
Date: 2018-07-24 23:26:09 UTC Nous avons eu le meme type d'instabilité lors du retour du routeur. Tout est revenu à la normal après 1-2 minutes. La mise-à-jours est terminé.
--
We've got the same instability when the router came back. All is back to normal now after 1 or 2 minutes. The update is now finished.
Date: 2018-07-24 23:01:31 UTC rbx6-sdagg1a-a72 a ete mise-à-jours. Nous débutons sur rbx6-sdagg1b-a72
rbx6-sdagg1a-a72 is now updated. We will begin on rbx6-sdagg1b-a72.
Date: 2018-07-24 22:50:51 UTC Nous avons constatés 1 min de loss lorsque rbx6-sdagg1a-a72 a redémarré pour l'upgrade. Cela semble relié à la convergence MLAG. Tout est revenu à la normale.
--
We seen 1 min of loss when rbx6-sdagg1a-a72 has rebooted. It seem related to a MLAG convergence. Everything is back to normal.
Date: 2018-07-24 22:18:26 UTC Nous débutons la mise-à-jours avec rbx6-sdaggsd1a-a72.
Date: 2018-07-23 22:50:21 UTC gra-iplb2-a70 est remis en production. La maintenance est terminée avec succès
--
gra-iplb2-a70 is back to production. The maintenance is finished with success.
Date: 2018-07-23 22:28:54 UTC gra-iplb2-a70 est isolé et sera redémarré.
--
gra-iplb2-a70 is isolated and will be reload.
Date: 2018-07-23 22:24:02 UTC gra-iplb1-a70 est remis en production. Nous débutons la maintenance sur gra-iplb2-a70.
--
gra-iplb1-a70 is back to production. We will start the maintenance on gra-iplb2-a70.
Date: 2018-07-23 22:06:35 UTC gra-iplb1-a70 est isolé et sera redémarré
--
gra-iplb1-a70 is isolated and will be rebooted.
Date: 2018-07-23 21:49:41 UTC Nous allons débuter la maintenance.
--
We start the maintenance.
Date: 2018-07-16 23:33:17 UTC Nous faisons un rollback pour rbx-iplb1/2-a70, la maintenance sera replanifée
We're rollbacking rbx-iplb1/2-a70, maintenance is postpone
Date: 2018-07-16 23:24:16 UTC Les port-channel ne veulent pas monter, nous investiguons
Date: 2018-07-16 07:49:02 UTC gra1-sd4b-n9 a reload avant le début de l'upgrade.
gra1-sd4b-n9 has reload before the beginning of the upgrade.
Date: 2018-07-16 07:27:07 UTC We're starting the upgrade of gra1-sd4ab-n9.
Démarrage de la maintenance du couple gra1-sd4ab-n9.
Date: 2018-07-12 00:33:39 UTC gra-iplb3-a70 upgraded and gra-iplb4-a70 had an issue with BGP sessions. The configuration was rolled-back for troubleshooting.
Date: 2018-07-11 22:00:08 UTC We're starting the upgrade of gra-iplb3/4-a70.
Démarrage de la maintenance du couple gra-iplb3/4-a70.
Date: 2018-07-09 23:24:43 UTC We stopped the upgrade for sbg-iplb1/2-a70, an issue with Port-Channel. Rolling back and troubleshooting.
Date: 2018-07-09 21:58:33 UTC We're starting the upgrade of sbg-iplb1/2-a70.
Démarrage de la maintenance du couple sbg-iplb1/2-a70.
Date: 2018-07-05 09:00:48 UTC Maintenance on sbg-iplb1/2-a70 postponed to July, 10th
Maintenance on gra-iplb1/2-a70 postponed to July, 24th
Date: 2018-07-05 03:00:23 UTC Upgrade is now finished on rbx6-sd1a/b-n9. devices.
La mise à jour est maintenant terminée pour ce couple.
Date: 2018-07-05 02:09:17 UTC All traffic is now going through rbx6-sd1b-n9. Upgrading rbx6-sd1a-n9.
Tout le trafic s'écoule via rbx6-sd1b-n9. Mise à jour de rbx6-sd1a-n9
Date: 2018-07-05 01:06:01 UTC rbx6-sd1b-n9 upgraded successfuly. Now swapping all traffic through rbx6-sd1b-n9
rbx6-sd1b-n9 mis à jour. Balance du trafic global via rbx6-sd1b-n9
Date: 2018-07-05 01:05:12 UTC erreur/ correction
All traffic is now going through rbx6-sd1a-n9. Upgrading rbx6-sd1b-n9.
Tout le trafic s'écoule via rbx6-sd1a-n9. Mise à jour de rbx6-sd1b-n9.
Date: 2018-07-05 00:45:19 UTC All traffic is now going through gra1-sdagg1a-n9. Upgrading gra1-sdagg1b-n9.
Tout le trafic s'écoule via gra1-sdagg1a-n9. Mise à jour de gra1-sdagg1b-n9
Date: 2018-07-04 23:50:18 UTC Swapping all traffic on rbx6-sd1a-n9.
Balance du trafic global sur rbx6-sd1a-n9.
Date: 2018-07-04 23:38:58 UTC Preparing the upgrade of rbx6-sd1a/b-n9 devices.
Préparation de la mise à jour du couple rbx6-sd1a/b-n9.
Date: 2018-07-04 02:15:01 UTC Upgrade is now finished on gra1-sdagg1a/b-n9. devices.
La mise à jour est maintenant terminée pour ce couple.
Date: 2018-07-04 01:57:54 UTC All traffic is now going through gra1-sdagg1a-n9. Upgrading gra1-sdagg1b-n9.
Tout le trafic s'écoule via gra1-sdagg1a-n9. Mise à jour de gra1-sdagg1b-n9
Date: 2018-07-04 01:43:00 UTC gra1-sdagg1a-n9 upgraded successfuly. Now swapping all traffic through gra1-sdagg1b-n9
gra1-sdagg1a-n9 mis à jour. Balance du trafic global via gra1-sdagg1b-n9
Date: 2018-07-04 01:34:48 UTC All traffic is now going through gra1-sdagg1b-n9. Upgrading gra1-sdagg1a-n9.
Tout le trafic s'écoule via gra1-sdagg1b-n9. Mise à jour de gra1-sdagg1a-n9
Date: 2018-07-04 01:08:24 UTC Swapping all traffic on gra1-sdagg1b-n9.
Balance du trafic global sur gra1-sdagg1b-n9.
Date: 2018-07-04 01:08:08 UTC Swapping all traffic on gra1-sdagg1a/b-n9.
Balance du trafic global sur gra1-sdagg1a/b-n9.
Date: 2018-07-04 00:59:50 UTC Preparing the upgrade of gra1-sdagg1a/b-n9-n9 devices.
Préparation de la mise à jour du couple gra1-sdagg1a/b-n9.
Date: 2018-06-29 07:59:36 UTC gra1-sdagg1a/b-n9 and sbg2-sd4a/b-n9 upgrades are postponed.
Les mises à jour des couples gra1-sdagg1a/b-n9 et sbg2-sd4a/b-n9 sont repoussées.
Date: 2018-06-28 10:36:38 UTC Upgrade is now finished on sbg2-sd5ab-n9 devices.
La mise à jour est maintenant terminée pour ce couple.
Date: 2018-06-28 10:07:50 UTC All traffic is now going through sbg2-sd5a-n9. Upgrading sbg2-sd5b-n9.
Tout le trafic s'écoule via sbg2-sd5a-n9. Mise à jour de sbg2-sd5b-n9.
Date: 2018-06-28 09:33:49 UTC sbg2-sd5a-n9 upgraded successfuly. Now swapping all traffic through sbg2-sd5a-n9.
sbg2-sd5a-n9 mis à jour. Balance du trafic global via sbg2-sd5a-n9.
Date: 2018-06-28 09:22:05 UTC All traffic is now going through sbg2-sd5b-n9. Upgrading sbg2-sd5a-n9.
Tout le trafic s'écoule via sbg2-sd5b-n9. Mise à jour de sbg2-sd5a-n9.
Date: 2018-06-28 08:54:19 UTC Swapping all traffic on sbg2-sd5b-n9.
Balance du trafic global sur sbg2-sd5b-n9.
Date: 2018-06-28 08:05:55 UTC Preparing the upgrade of sbg2-sd5a/b-n9 devices.
Préparation de la mise à jour du couple sbg2-sd5a/b-n9.
Date: 2018-06-27 10:52:00 UTC Upgrade is now finished on sbg2-sd6ab-n9 devices. Despite precautions, we have faced 10 min loss issues for some Vlans for each device. We're analyzing the cause of those losses.
La mise à jour est maintenant terminée pour ce couple. Malgré toutes les précautions prises, nous avons subi une perte de trafic de 10 min pour certains Vlan pour chaque équipement. Nous analysons la cause de ces pertes.
Date: 2018-06-27 10:39:03 UTC sbg2-sd6a-n9 upgraded successfuly. Now swapping all traffic through sbg2-sd6a-n9.
sbg2-sd6a-n9 mis à jour. Balance du trafic global via sbg2-sd6a-n9.
Date: 2018-06-27 09:57:37 UTC All traffic is now going through sbg2-sd6b-n9. Upgrading sbg2-sd6a-n9.
Tout le trafic s'écoule via sbg2-sd6b-n9. Mise à jour de sbg2-sd6a-n9.
Date: 2018-06-27 09:01:48 UTC sbg2-sd6b-n9 upgraded successfuly. Now swapping all traffic through sbg2-sd6b-n9.
sbg2-sd6b-n9 mis à jour. Balance du trafic global via sbg2-sd6b-n9.
Date: 2018-06-27 08:43:43 UTC All traffic is now going through sbg2-sd6a-n9. Upgrading sbg2-sd6b-n9.
Tout le trafic s'écoule via sbg2-sd6a-n9. Mise à jour de sbg2-sd6b-n9.
Date: 2018-06-27 07:55:06 UTC Swapping all traffic on sbg2-sd6a-n9.
Balance du trafic global sur sbg2-sd6a-n9.
Date: 2018-06-27 07:37:27 UTC Preparing the upgrade of sbg2-sd6a/b-n9 devices.
Préparation de la mise à jour du couple sbg2-sd6a/b-n9.
Date: 2018-06-26 09:15:14 UTC waw1-sd2a-n9 & waw1-sd2b-n9 upgraded successfuly.
Mises à jour waw1-sd2a-n9 & waw1-sd2b-n9 terminées.
Date: 2018-06-26 08:20:57 UTC Starting the upgrade of waw1-sd2b-n9.
Démarrage de la mise à jour sur waw1-sd2b-n9.
Date: 2018-06-26 08:18:20 UTC New feature applied successfuly on bhs-iplb1-a70/bhs-iplb2-a70.
Application du nouveau paramètre sur bhs-iplb1-a70/bhs-iplb2-a70 terminée avec succès.
Date: 2018-06-26 08:07:41 UTC Applying new available feature on bhs-iplb2-a70.
Application du paramètre nouvellement disponible sur bhs-iplb2-a70.
Date: 2018-06-26 08:00:41 UTC Applying new available feature on bhs-iplb1-a70.
Application du paramètre nouvellement disponible sur bhs-iplb1-a70.
Date: 2018-06-25 11:06:38 UTC bhs-iplb2-a70 has been upgraded.
Mise à jour terminée sur bhs-iplb2-a70.
Date: 2018-06-25 10:54:54 UTC Now upgrading bhs-iplb2-a70.
Nous procédons à la mise à jour de bhs-iplb2-a70
Date: 2018-06-25 10:40:32 UTC bhs-iplb1-a70 has been upgraded. Waiting for all BGP sessions from downside devices to come back up.
bhs-iplb1-a70 a été mis à jour. Nous attendons la remontée de toutes les sessions BGP des équipements en aval.
Date: 2018-06-25 10:02:22 UTC Problem has been fixed. Resuming the operation.
Le problème a été corrigé. Nous reprenons l'opération.
Date: 2018-06-25 09:06:08 UTC A problem in the redundancy of the devices connected to this couple has been found. Rolling back and troubleshooting.
Un problème dans la redondance des équipements attachés à ce couple a été trouvé. Analyse en cours.
Date: 2018-06-25 08:19:58 UTC We're starting the upgrade of bhs-iplb1/2-a70.
Démarrage de la maintenance du couple bhs-iplb1/2-a70.