Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
79.137.0.0/17 is now 99% visible by RIS RIPE Service. We will check to remove old configuration on next Tuesday about splitted /18 (79.137.0.0/18 + 79.137.64.0/18) so issue will not happen anymore.
Date: 2018-07-05 18:50:41 UTC Nous avons automatisé une partie des déploiements des annonces pour favoriser l'intégration simple des IPs chez OVH/AS16276 (aka Bring your own IPs).
Certains équipements sont maintenant mis à jour par un robot qui se base sur une base de données internes des IPs. Afin d'automatiser ce processus, nous avons du standardiser et uniformiser la configuration de certains routeurs.
Cette uniformisation et cette automatisation est ok et sans faille constatée.
Cependant, une configuration historique faisait que 79.137.0.0/17 était annoncée en 79.137.0.0/18 + 79.137.64.0/18, ce qui n'est pas le standard dans nos bases de données. Par conséquent, les annonces de 79.137.0.0/17 ont disparu progressivement depuis 10 jours au fur et à mesure des mises en conformité des configurations des routeurs de bordure, qui s'est terminée aujourd'hui par th2-1-a9, l'un de nos plus gros routeurs avec les peers français.
La situation a été corrigé à 20h30 UTC+2 ce soir, nous déployons le fix sur l'ensemble de l'infrastructure dès maintenant.
----
We have automated some of the deployments to support easier IPs integration at OVH / AS16276 (aka Bring your own IPs).
Some equipments are now updated by a robot based on an internal IPs database. In order to automate this process, we have to standardize the configuration of some routers.
This standardization and automation is ok and flawless.
However, a historical configuration was that 79.137.0.0/17 was announced in 79.137.0.0/18 + 79.137.64.0/18, which is not the standard in our databases. As a result, the 79.137.0.0/17 announcements have been phased out over the last 10 days as edge routing configurations have been brought into compliance, which ended today with th2-1-a9, one of our biggest routers with French peers.
The situation has been fixed at 8:30pm UTC+2, we are deploying fix on the entire infrastructure right now.
Date: 2018-07-05 18:21:09 UTC Nous avons identifié un problème d'annonce de certains prefixes. Pour le moment nous avons identifié 79.137.0.0/17.
----
We have identified a problem of annoucement on some prefixes. For the moment identified 79.137.0.0/17.