FS#3347 — performances

Attached to Project— Emails
Maintenance
tous les emails
CLOSED
100%
Les performances de certains filers ne sont pas encore au rendez vous.
Nous allons mettre en place des outils pour pouvoir monitorer la
qualité de service.

En attandant, le filerz76 va subir l'ajout d'un 5ème disque en parallele
dans le but d'augmenter encore les performances.
Date:  Monday, 07 September 2009, 23:14PM
Reason for closing:  Done
Comment by OVH - Tuesday, 01 September 2009, 20:48PM

scrub: resilver in progress for 0h0m, 0.04% done, 35h46m to go


Comment by OVH - Wednesday, 02 September 2009, 00:41AM

scrub: resilver in progress for 3h53m, 33.02% done, 7h54m to go


Comment by OVH - Wednesday, 02 September 2009, 06:40AM

scrub: resilver in progress for 9h52m, 91.08% done, 0h58m to go


Comment by OVH - Wednesday, 02 September 2009, 06:50AM

filerz164
ajout d'un disque


Comment by OVH - Wednesday, 02 September 2009, 07:13AM

nous allons nous occuper aussi de
filerz75
filerz76 en cours
filerz79
filerz80
filerz82
filerz122
filerz123
filerz124
filerz125
filerz126
filerz132
filerz138
filerz142
filerz148
filerz164 en cours
filerz171
filerz178
filerz186

les autres 63 filers sont okey.


Comment by OVH - Wednesday, 02 September 2009, 07:27AM

filerz75 nous avons ajouté le 4ème pool RAID-1 dans le RAID-0


Comment by OVH - Wednesday, 02 September 2009, 07:28AM

filerz79
le 4ème disque dans le 3ème RAID-1 a été ajouté


Comment by OVH - Wednesday, 02 September 2009, 08:19AM

filerz76
scrub: resilver in progress for 11h29m, 92.33% done, 0h57m to go
filerz79
scrub: resilver in progress, 1.75% done, 47h23m to go
filerz164
scrub: resilver in progress for 0h54m, 23.62% done, 2h55m to go


Comment by OVH - Wednesday, 02 September 2009, 12:20PM

filerz76
scrub: resilver in progress for 15h31m, 97.22% done, 0h26m to go
filerz79
scrub: resilver in progress, 16.85% done, 23h59m to go
filerz164 fini


Comment by OVH - Wednesday, 02 September 2009, 14:33PM

filerz76
scrub: resilver completed after 17h5m with 0 errors on Wed Sep 2 13:54:25 2009


Comment by OVH - Wednesday, 02 September 2009, 17:10PM

filerz79
scrub: resilver in progress, 36.15% done, 17h7m to go
filerz164 FINI


Comment by OVH - Wednesday, 02 September 2009, 20:19PM

filerz75
un nouveau disque ajouté
filerz76
un nouveau disque ajouté
filerz79
scrub: resilver in progress, 48.68% done, 13h25m to go
filerz164
un nouveau disque ajouté


Comment by OVH - Wednesday, 02 September 2009, 20:23PM

filerz80
un nouveau disque ajouté


Comment by OVH - Thursday, 03 September 2009, 00:06AM

filerz75
scrub: resilver in progress, 8.30% done, 42h18m to go
filerz76
scrub: resilver in progress for 3h51m, 28.37% done, 9h44m to go
filerz79
scrub: resilver in progress, 67.32% done, 8h4m to go
filerz80
scrub: resilver in progress, 49.31% done, 3h48m to go
filerz164
un nouveau disque attaché



Comment by OVH - Thursday, 03 September 2009, 06:07AM

filerz75
scrub: resilver in progress, 40.12% done, 14h41m to go
filerz76
scrub: resilver in progress for 9h52m, 68.09% done, 4h37m to go
filerz79
scrub: resilver in progress, 90.45% done, 2h23m to go
filerz80
scrub: resilver in progress, 86.32% done, 0h56m to go
filerz164
un nouveau disque attaché


Comment by OVH - Thursday, 03 September 2009, 10:08AM

filerz75
scrub: resilver in progress, 84.91% done, 2h27m to go
filerz76
scrub: resilver in progress for 13h53m, 91.34% done, 1h19m to go
filerz79
scrub: resilver in progress, 95.64% done, 1h12m to go
filerz80
scrub: resilver in progress, 96.60% done, 0h20m to go
filerz164
FINI: il reste 2 disques à ajouter.


Comment by OVH - Thursday, 03 September 2009, 11:44AM

filerz80
fini. il reste 1 disque à ajouter.


Comment by OVH - Thursday, 03 September 2009, 15:10PM

filerz148
nous ajoutons de la ram sur le filer.


Comment by OVH - Thursday, 03 September 2009, 16:46PM

filerz76 fini. lui il est terminé de chez terminé


Comment by OVH - Thursday, 03 September 2009, 16:49PM

filerz75
scrub: resilver in progress, 89.83% done, 2h19m to go
filerz79 fini


Comment by OVH - Friday, 04 September 2009, 03:35AM

filerz75
on a trouvé un disque defaillant (lent). on l'a viré.
un nouveau disque est en syncronisation.


Comment by OVH - Saturday, 05 September 2009, 23:07PM

filerz75 fini.
filerz80
un disque ajouté


Comment by OVH - Monday, 07 September 2009, 23:14PM

Pour l'instant, toutes les opérations sont terminés. Rien n'est
en cours. Le fonctionnement s'est nettement amélioré. Nous allons
continuer les opérations dans les prochains jours.