Date: 2009-10-13 05:27:08 UTC Il nous manque ESPANIX, MIX et PLIX.
Puis le route collector sur AMSIX & LINX.
Sinon :)
# dig . nsmaster.nic.fr | grep 2001
ns1.nic.fr. 157427 IN AAAA 2001:660:3005:1::1:1
ns4.ext.nic.fr. 157427 IN AAAA 2001:610:240:0:53::4
ns3.nic.fr. 52619 IN AAAA 2001:660:3006:1::1:1
ns2.nic.fr. 157427 IN AAAA 2001:660:3005:1::1:2
# traceroute6 2001:660:3005:1::1:1
traceroute to 2001:660:3005:1::1:1 (2001:660:3005:1::1:1) from 2001:41d0:1:7b8b::1, 30 hops max, 16 byte packets
1 2001:41d0:1:7bff:ff:ff:ff:ff (2001:41d0:1:7bff:ff:ff:ff:ff) 3.74 ms * 0.731 ms
2 ipv6.rbx-2-6k.routers.net (2001:41d0::552) 24.418 ms 0.623 ms *
3 ipv6.th2-1-6k.routers.net (2001:41d0::5b1) 4.229 ms * 4.259 ms
4 renater-ix1.sfinx.tm.fr (2001:7f8:4e:2::102) 5.53 ms * *
5 te2-1-paris1-rtr-021.noc.renater.fr (2001:660:7903:b:2::2) 4.354 ms 4.302 ms 4.319 ms
6 gi0-2-afnic.noc.renater.fr (2001:660:3000:3c:10:86::) 5.249 ms 5.091 ms 5.079 ms
7 afnic-client-vl11-gi0-3-afnic.noc.renater.fr (2001:660:300c:1002:131::2485) 5.182 ms 5.193 ms 5.149 ms
8 * * *
9 * * *
10 * *^C
# traceroute6 2001:660:3006:1::1:1
traceroute to 2001:660:3006:1::1:1 (2001:660:3006:1::1:1) from 2001:41d0:1:7b8b::1, 30 hops max, 16 byte packets
1 2001:41d0:1:7bff:ff:ff:ff:ff (2001:41d0:1:7bff:ff:ff:ff:ff) 0.594 ms * *
2 ipv6.rbx-2-6k.routers.net (2001:41d0::552) 0.734 ms * 0.64 ms
3 ipv6.th2-1-6k.routers.net (2001:41d0::5b1) 4.139 ms * 89.577 ms
4 afnic-saint-quentin.sfinx.tm.fr (2001:7f8:4e:2::238) 10.087 ms 4.185 ms 4.206 ms
5 ns3.nic.fr (2001:660:3006:1::1:1) 3.978 ms 4.028 ms 3.984 ms
# traceroute6 2001:610:240:0:53::4
traceroute to 2001:610:240:0:53::4 (2001:610:240:0:53::4) from 2001:41d0:1:7b8b::1, 30 hops max, 16 byte packets
1 2001:41d0:1:7bff:ff:ff:ff:ff (2001:41d0:1:7bff:ff:ff:ff:ff) 9.184 ms * 11.432 ms
2 2001:41d0::602 (2001:41d0::602) 12.25 ms * 8.127 ms
3 de-cix.fra20.ip6.tiscali.net (2001:7f8::cb9:0:1) 8.551 ms 8.792 ms 8.449 ms
4 xe-2-1-0.fra23.ip6.tinet.net (2001:668:0:2::1:1822) 8.43 ms 8.461 ms 8.714 ms
5 xe-10-2-0.ams20.ip6.tinet.net (2001:668:0:2::1:1961) 15.071 ms 15.2 ms 14.911 ms
6 xe-7-0-0.ams10.ip6.tinet.net (2001:668:0:2::1:1351) 15.415 ms 15.289 ms 15.442 ms
7 gw.ipv6.amsix.nikrtr.ripe.net (2001:7f8:1::a500:3333:1) 21.892 ms 20.544 ms 16.207 ms
8 ns-sec.ripe.net (2001:610:240:0:53::4) 16.201 ms 15.807 ms 16.101 ms
Date: 2009-10-11 11:33:14 UTC les peers ont été configuré.
SFINX up
DECIX up
Date: 2009-10-07 16:26:51 UTC fait
on va maintenant pouvoir demander les IPv6 sur chaque point de peering
puis on va lancer les demandes de peering en IPv6. de même on va renforcer
les peering via nos fournisseurs de transit.
Date: 2009-10-07 16:18:47 UTC fait
bruxelles
Date: 2009-10-07 16:14:08 UTC fait
la boucle
marseille/madrid/paris
Date: 2009-10-07 16:06:19 UTC fait
la boucle
milano/marseill/lyon/paris
Date: 2009-10-07 16:02:37 UTC fait
maintenant
roubaix/london
Date: 2009-10-07 15:51:38 UTC fait
maintenant la boucle
roubaix/amsterdam/varsovie/prague
Date: 2009-10-07 15:33:38 UTC fait.
maintenant la boucle:
frankfurt/prague/vienne/milano/zurich/frankfurt
Date: 2009-10-07 15:16:35 UTC Paris: refait.
on attaque Frankfurt.