Get webhook notifications whenever Network & Infrastructure creates an incident, updates an incident, resolves an incident or changes a component status.
Le 16 Octobre (vendredi) nous avons eu une alerte
AL1 r rbx-63-m2 (11:44:13)
UP1 r rbx-63-m2 (11:49:13)
Le routeur a redemarré la carte #2 et il est repassé sur la carte #1
Oct 16 11:42:29 rbx-63-m1.routers.ovh.net 2779: Oct 16 11:42:25 GMT: %SCP-5-ONLINE: Module online (supervisor switchover)
Oct 16 11:42:30 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:42:25 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 1
Oct 16 11:42:31 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:42:26 %SYS-5-MOD_OK:Module 15(WS-F6K-MSFC2) is online
Nous avons changé la carte #2
Oct 16 11:45:44 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:45:40 %SYS-5-MOD_REMOVE:Module 2 has been removed
Oct 16 11:45:48 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:45:43 %SYS-5-MOD_INSERT:Module 2 has been inserted
Oct 16 11:47:43 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:47:39 %SYS-5-SUP_MODSBY:Module 2 is in standby mode
Oct 16 11:48:06 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:48:01 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 2
Oct 16 11:48:06 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:48:01 %SYS-5-PORT_SSUPOK:Ports on standby supervisor (module 2) are up
Oct 16 11:48:53 rbx-63-c1.routers.ovh.net 2009 Oct 16 09:48:49 %SYS-5-MOD_OK:Module 16(WS-F6K-MSFC2) is online
Update(s):
Date: 2009-10-18 09:14:55 UTC On a fermé un serveur qui envoyait une attaque.
Date: 2009-10-17 09:21:10 UTC on rebascule vers la carte #2.
Date: 2009-10-17 06:13:54 UTC Ce trafic était dû au flux netflow qui a été activé (juste pour voir
si c'est pas une attaque qui a explosé le m2). On vient de l'enlever.
Tout est revenu à la normale.
Date: 2009-10-17 06:01:31 UTC Depuis, il y a un fort trafic entre la carte de switching et la carte
de routing. Un trafic interne.