FS#3715 — OpenSolaris 2009.03 and zones
Attached to Project— Distributions et OS
| Incident | |
| autre | |
| CLOSED | |
![]() |
An UUID is missing on global zone zfs which prevent user to create zones.
# zfs get -H org.opensolaris.libbe:uuid rpool/ROOT/opensolaris
rpool/ROOT/opensolaris org.opensolaris.libbe:uuid - -
should be :
rpool/ROOT/opensolaris org.opensolaris.libbe:uuid xxxxxxx-xxxxx-xxxxx-xxxx-xxxxxxxxxxxx local
Image installer is being fixed.
Date: Monday, 04 January 2010, 18:59PM# zfs get -H org.opensolaris.libbe:uuid rpool/ROOT/opensolaris
rpool/ROOT/opensolaris org.opensolaris.libbe:uuid - -
should be :
rpool/ROOT/opensolaris org.opensolaris.libbe:uuid xxxxxxx-xxxxx-xxxxx-xxxx-xxxxxxxxxxxx local
Image installer is being fixed.
Reason for closing: Done
Additional comments about closing: Bug is fixed.
RSS for all categories

Workaround is possible without re-installing server :
generate your uuid :
# makeuuid
xxxxxxxx-1dd2-11b2-9ecb-00304832cd88
apply uuid to your main zfs :
# zfs set org.opensolaris.libbe:uuid=xxxxxxxx-1dd2-11b2-9ecb-00304832cd88 rpool/ROOT/opensolaris