Le routeur a buggé.
Date: Saturday, 29 May 2010, 14:42PMReason for closing: Done
RSS for all categories

Nous sommes en dans l'état "#2 master, #1 en cours de boot".
et d'après l'historique nous étions (avec 1444 jours d'uptime)
en "#1 master".
Quel est la théorie ce matin ? Regardons au fond du café noir.
Mouais ...
Le routeur s'est fait un harakiri
May 29 03:46:17 p19-20-c1.routers.ovh.net 2010 May 29 01:45:59 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 3 not responding... resetting module
May 29 03:46:17 p19-20-c1.routers.ovh.net 2010 May 29 01:45:59 %SYS-5-MOD_RESET:Module 3 reset from Software
May 29 03:46:19 p19-20-c1.routers.ovh.net 2010 May 29 01:46:01 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 4 not responding... resetting module
May 29 03:46:19 p19-20-c1.routers.ovh.net 2010 May 29 01:46:01 %SYS-5-MOD_RESET:Module 4 reset from Software
May 29 03:46:21 p19-20-c1.routers.ovh.net 2010 May 29 01:46:03 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 5 not responding... resetting module
May 29 03:46:21 p19-20-c1.routers.ovh.net 2010 May 29 01:46:03 %SYS-5-MOD_RESET:Module 5 reset from Software
May 29 03:46:23 p19-20-c1.routers.ovh.net 2010 May 29 01:46:05 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 6 not responding... resetting module
May 29 03:46:23 p19-20-c1.routers.ovh.net 2010 May 29 01:46:05 %SYS-5-MOD_RESET:Module 6 reset from Software
May 29 03:46:25 p19-20-c1.routers.ovh.net 2010 May 29 01:46:07 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 8 not responding... resetting module
May 29 03:46:25 p19-20-c1.routers.ovh.net 2010 May 29 01:46:07 %SYS-5-MOD_RESET:Module 8 reset from Software
May 29 03:46:27 p19-20-c1.routers.ovh.net 2010 May 29 01:46:09 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 15 not responding... resetting module
May 29 03:46:27 p19-20-c1.routers.ovh.net 2010 May 29 01:46:09 %SYS-5-MOD_RESET:Module 15 reset from Software
May 29 03:46:29 p19-20-c1.routers.ovh.net 2010 May 29 01:46:11 %SYS-5-MOD_NOSCPPINGRESPONSE:Module 16 not responding... resetting module
May 29 03:46:29 p19-20-c1.routers.ovh.net 2010 May 29 01:46:11 %SYS-5-MOD_RESET:Module 16 reset from Software
May 29 03:54:49 p19-20-c1.routers.ovh.net 2010 May 29 01:54:31 %SYS-5-MOD_OK:Module 6 is online
May 29 03:54:49 p19-20-c1.routers.ovh.net 2010 May 29 01:54:31 %VTP-2-ISL1QMAPSCPSTATUSNOTSUPPORTED:Module 6 does not support vlan mapping
May 29 03:54:49 p19-20-c1.routers.ovh.net 2010 May 29 01:54:31 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 6
May 29 03:54:54 p19-20-c1.routers.ovh.net 2010 May 29 01:54:36 %SYS-5-MOD_OK:Module 8 is online
May 29 03:54:54 p19-20-c1.routers.ovh.net 2010 May 29 01:54:36 %VTP-2-ISL1QMAPSCPSTATUSNOTSUPPORTED:Module 8 does not support vlan mapping
May 29 03:54:54 p19-20-c1.routers.ovh.net 2010 May 29 01:54:36 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 8
May 29 03:54:59 p19-20-c1.routers.ovh.net 2010 May 29 01:54:41 %SYS-5-MOD_OK:Module 4 is online
May 29 03:54:59 p19-20-c1.routers.ovh.net 2010 May 29 01:54:41 %VTP-2-ISL1QMAPSCPSTATUSNOTSUPPORTED:Module 4 does not support vlan mapping
May 29 03:54:59 p19-20-c1.routers.ovh.net 2010 May 29 01:54:41 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 4
May 29 03:55:04 p19-20-c1.routers.ovh.net 2010 May 29 01:54:46 %SYS-5-MOD_OK:Module 5 is online
May 29 03:55:04 p19-20-c1.routers.ovh.net 2010 May 29 01:54:46 %VTP-2-ISL1QMAPSCPSTATUSNOTSUPPORTED:Module 5 does not support vlan mapping
May 29 03:55:04 p19-20-c1.routers.ovh.net 2010 May 29 01:54:47 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 5
May 29 03:55:10 p19-20-c1.routers.ovh.net 2010 May 29 01:54:52 %SYS-5-MOD_OK:Module 3 is online
May 29 03:55:10 p19-20-c1.routers.ovh.net 2010 May 29 01:54:52 %VTP-2-ISL1QMAPSCPSTATUSNOTSUPPORTED:Module 3 does not support vlan mapping
May 29 03:55:10 p19-20-c1.routers.ovh.net 2010 May 29 01:54:52 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 3
pas habituel.
ce qui m'intrige c'est
May 29 03:50:01 p19-20-c1.routers.ovh.net 2010 May 29 01:49:43 %ETHC-5-PORTFROMSTP:Port 2/2 left bridge port 1/1,2/2
ou encore
May 29 03:57:59 p19-20-c1.routers.ovh.net 2010 May 29 01:57:41 %ETHC-5-PORTFROMSTP:Port 2/2 left bridge port 2/2
May 29 03:57:59 p19-20-c1.routers.ovh.net 2010 May 29 01:57:42 %ETHC-5-PORTTOSTP:Port 2/2 joined bridge port 1/1,2/2
très interessant.
p19-20-c1> (enable) 2010 May 29 02:10:53 %SYS-2-MOD_NOSCPRESPONSE:Module 1 not responding over SCP
je prefere. on change la carte #1
La carte que nous avons mis en place ne demarre pas entierement.
On va changer.
Changé, syncronisé et en fonctionnement.