FS#4527 — BFD

Attached to Project— Reseau Internet et Baies
Amélioration
Tout le réseau
CLOSED
100%
Nous avons testé le BFD sur l'OSPF (Bidirectional Forwarding Detection)
entre ldn-1-6k et ams-1-6k. Cela fonctionne bien. Par contre au moindre
surcharge du routeur, le BFD ne repond pas bien et le lien est declaré
down. C'est une fonctionnalité trop dangereusse pour la mettre en production.
Nous allons nous en passer. C'est à dire que quand le lien est down, l'OSPF
mettra entre 1 à 3 secondes pour rerouter les packets au lieu de entre
50 et 250ms.
Date:  Sunday, 29 August 2010, 11:50AM
Reason for closing:  Done
Comment by OVH - Sunday, 29 August 2010, 11:48AM

Aug 28 15:02:51 GMT: %BFD_TEST-7-CONFIG: Config changed on interface Port-channel1 to ON.
Aug 28 15:03:39 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 28 15:03:46 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 28 15:05:02 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 28 15:05:06 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Doneobj: [0x7146FF78] event_id: [0x00000003] er_p: [0x00000000] arg: [0x00000000] session state FAILING -> Unknown
Aug 29 08:47:15 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 29 08:47:32 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 29 08:48:32 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 29 08:48:44 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 29 08:51:08 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 29 08:51:19 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 29 08:51:56 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 29 08:52:16 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 29 08:55:05 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from FULL to DOWN, Neighbor Down: BFD node down
Aug 29 08:55:06 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Doneobj: [0x5A162B78] event_id: [0x00000003] er_p: [0x00000000] arg: [0x00000000] session state FAILING -> Unknown
Aug 29 08:55:44 GMT: %OSPF-5-ADJCHG: Process 16276, Nbr 30.94 on Port-channel1 from LOADING to FULL, Loading Done
Aug 29 10:43:13 GMT: %BFD_TEST-7-CONFIG: Config changed on interface Port-channel1 to OFF.


Comment by OVH - Sunday, 29 August 2010, 11:50AM

test fait avec

ip ospf bfd
bfd interval 50 min_rx 50 multiplier 5

ça a sauté de suite

ip ospf bfd
bfd interval 250 min_rx 250 multiplier 3

ça a tenu la nuit puis à nouveau plusieurs faux positives