FS#4547 — Roubaix <> Francfort

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Le lien Roubaix<>Francfort est interrompu. Le trafic s'écoule à travers le lien de backup Paris<>Francfort.
Date:  Friday, 03 September 2010, 16:07PM
Reason for closing:  Done
Comment by OVH - Friday, 03 September 2010, 12:44PM

coupure ou pb entre Katzenelnbogen(de) et Plaidt(de)


Comment by OVH - Friday, 03 September 2010, 13:00PM

reroutage:
fra/zur 10x
fra/mil 10x
fra/pra 10x
fra/var 10x
mil/vie 10x

consequence:
zur/mil/vie on le fait via lyon/marselle/milano
pra on le voit via varsovie

on sature presque plus entre paris/frankfurt

avec la mise en place du route reflector on n'a pas
eu de coupure dans le trafic, juste saturation entre
paris/frankfurt.


Comment by OVH - Friday, 03 September 2010, 13:05PM

on reroute telecom italia sur le backup à paris au lieu de milano
on reroute TATA à paris au lieu de frankfurt


Comment by OVH - Friday, 03 September 2010, 13:38PM

Il s'agirait d'un incident entre le site d'amplification de Katzenelnbogen en Allemagne et Francfort. Plus d'infos à venir.


Comment by OVH - Friday, 03 September 2010, 16:06PM

Après les recherches, quelqu'un a deconnecté nos fibres optiques (peut etre
par l'erreur) et les a remis en les inversants. Nous avons fait les mesures
et nous avons remis en place le lien en inversant à nouveau les fibres optiques
TX/RX.

Le lien est up.

Les reroutage ont été annulés. Tout s'ecoule normalement.