FS#4560 — gsw-1
Attached to Project— Reseau Internet et Baies
| Incident | |
| Tout le réseau | |
| CLOSED | |
![]() |
La carte 7 a reloadé
Sep 6 20:48:00 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:07:28 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:08:32 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:11:33 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:12:40 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:14:47 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:15:29 GMT: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 7 to recover from error: Linecard received system exception
Sep 6 21:15:29 GMT: %OIR-SP-3-PWRCYCLE: Card in module 7, is being power-cycled Off (Module Reset due to exception or user request)
Sep 6 21:15:29 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 7 set Off (Module Reset due to exception or user request)
Sep 6 21:16:47 GMT: %SYS-DFC7-5-RESTART: System restarted --
Sep 6 21:17:10 GMT: %DIAG-SP-6-DIAG_OK: Module 7: Passed Online Diagnostics
Date: Tuesday, 07 September 2010, 03:07AMSep 6 20:48:00 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:07:28 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:08:32 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:11:33 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:12:40 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:14:47 GMT: %EARL_L3_ASIC-DFC7-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt FIB interrupt
Sep 6 21:15:29 GMT: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 7 to recover from error: Linecard received system exception
Sep 6 21:15:29 GMT: %OIR-SP-3-PWRCYCLE: Card in module 7, is being power-cycled Off (Module Reset due to exception or user request)
Sep 6 21:15:29 GMT: %C6KPWR-SP-4-DISABLED: power to module in slot 7 set Off (Module Reset due to exception or user request)
Sep 6 21:16:47 GMT: %SYS-DFC7-5-RESTART: System restarted --
Sep 6 21:17:10 GMT: %DIAG-SP-6-DIAG_OK: Module 7: Passed Online Diagnostics
Reason for closing: Done
RSS for all categories

http://www.cisco.com/en/US/products/hw/switches/ps700/products_tech_note09186a00801b42bf.shtml#EARL
gsw-1-6k#sh run | i mls verify ip
gsw-1-6k#
on a rien de tout ça. donc c'est peut etre un probleme hardware.