FS#4586 — rbx-44

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Le routeur est down.
Date:  Friday, 17 September 2010, 12:50PM
Reason for closing:  Done
Comment by OVH - Friday, 10 September 2010, 18:32PM

Sep 10 18:28:38 rbx-44-c1.routers.ovh.net 2010 Sep 10 16:28:18 %SYS-1-MOD_SEQERROR:Switching bus sequence error occurred on module 6
Sep 10 18:28:38 rbx-44-c1.routers.ovh.net 2010 Sep 10 16:28:18 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 9 (asic=2, srcidx=0x340, seq=11)
Sep 10 18:28:38 rbx-44-c1.routers.ovh.net 2010 Sep 10 16:28:19 %SYS-5-SUP_MODSBY:Module 2 is in standby mode
Sep 10 18:28:44 rbx-44-c1.routers.ovh.net 2010 Sep 10 16:28:25 %SYS-3-MOD_PORTINTFOUTOFSYNC:Port Interface not in sync for Module 3


Comment by OVH - Friday, 10 September 2010, 18:44PM

Les 2 cartes ont plantés. La carte 1 a rebooté immédiatement alors que la carte #2 s'est retrouvé bloqué au boot. Nous avons forcé son redémarrage.


Comment by OVH - Friday, 10 September 2010, 18:48PM

Le routeur est revenu dans son fonctionnement normal. Nous le gardons néanmoins sous surveillance attentive.