FS#4587 — rbx-22

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Nous avons un incident sur ce routeur.
Date:  Saturday, 11 September 2010, 00:32AM
Reason for closing:  Done
Comment by OVH - Saturday, 11 September 2010, 00:32AM

nous avons eu un pb sur la carte #1 qui a entrainé un pb sur le bus de communication entre les cartes:
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 5 (asic=2, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 5 (asic=2, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 5 (asic=1, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 5 (asic=1, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 6 (asic=1, srcidx=0x341, seq=18)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 2 (asic=1, srcidx=0x341, seq=18)

le routage était complètement stoppé sur le routeur alors que toutes les cartes étaient ups. Après reboot forcé de la carte #1, la carte #2 a pris le controle et le routage a été rétabli.

La carte #1 a redémarré normalement. Nous sommes de nouveau dans un fonctionnement normal.