rbx-22
Incident Report for Network & Infrastructure
Resolved
Nous avons un incident sur ce routeur.

Update(s):

Date: 2010-09-10 22:32:31 UTC
nous avons eu un pb sur la carte #1 qui a entrainé un pb sur le bus de communication entre les cartes:
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 5 (asic=2, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 5 (asic=2, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 5 (asic=1, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_SEQMISMATCH:Bus asic sequence mismatch occurred on module 5 (asic=1, srcidx=0x7420, seq=12)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 6 (asic=1, srcidx=0x341, seq=18)
Sep 10 23:52:51 rbx-22-c1.routers.ovh.net 2010 Sep 10 21:52:31 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 2 (asic=1, srcidx=0x341, seq=18)

le routage était complètement stoppé sur le routeur alors que toutes les cartes étaient ups. Après reboot forcé de la carte #1, la carte #2 a pris le controle et le routage a été rétabli.

La carte #1 a redémarré normalement. Nous sommes de nouveau dans un fonctionnement normal.
Posted Sep 10, 2010 - 22:06 UTC