FS#4741 — ams-1-6k

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Nous avons du forcer le reboot du routeur.
Date:  Tuesday, 26 October 2010, 13:49PM
Reason for closing:  Done
Comment by OVH - Tuesday, 26 October 2010, 11:24AM

Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26734: Oct 26 10:20:36 GMT: %SYS-2-MALLOCFAIL: Memory allocation of 65536 bytes failed from 0x41044EEC, alignment 8
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26735: Pool: Processor Free: 11421984 Cause: Memory fragmentation
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26736: Alternate Pool: None Free: 0 Cause: No Alternate pool
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26737: -Process= "IP RIB Update", ipl= 0, pid= 164
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26738: -Traceback= 4102C83C 4103246C 41044EF4 413C2334 413C2578 4228B548 40641B40 42307BD0 409D3998 4098445C 4098457C
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26739: Oct 26 10:20:36 GMT: %FIB-3-NORPXDRQELEMS: Exhausted XDR queuing elements while preparing message for slot/cpu 7/0
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26740: -Process= "IP RIB Update", ipl= 0, pid= 164
Oct 26 11:21:02 40g.ams-1-6k.routers.ovh.net 26741: -Traceback= 413C273C 4228B548 40641B40 42307BD0 409D3998 4098445C 4098457C
Oct 26 11:21:09 40g.ams-1-6k.routers.ovh.net 26742: Oct 26 10:20:41 GMT: %FIB-3-NOMEM: Malloc Failure, disabling DCEF


Comment by OVH - Tuesday, 26 October 2010, 11:32AM

Le routeur est up. Il remonte les sessions.

Nous recevons cette semaine 3 nouveaux routeurs