OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
upgrade rbx-97-n7
Scheduled Maintenance Report for Network & Infrastructure
Completed
Nous allons mettre à jour le NX-OX sur le Nexus 7016.
Cette mise à jour s'effectue à chaud grâce au systeme
ISSU. Pas de panne à prevoir.

rbx-97-n7# sh redundancy status
Redundancy mode
---------------
administrative: HA
operational: HA

This supervisor (sup-9)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby

Other supervisor (sup-10)
------------------------
Redundancy state: Standby

Supervisor state: HA standby
Internal state: HA standby

System start time: Wed Jul 21 00:19:40 2010

System uptime: 103 days, 18 hours, 23 minutes, 4 seconds
Kernel uptime: 67 days, 15 hours, 8 minutes, 3 seconds
Active supervisor uptime: 57 days, 0 hours, 47 minutes, 30 seconds


rbx-97-n7# sh ver
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2010, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php

Software
BIOS: version 3.22.0
loader: version N/A
kickstart: version 5.0(3)
system: version 5.0(3)
BIOS compile time: 02/20/10
kickstart image file is: bootflash:/n7000-s1-kickstart.5.0.3.bin
kickstart compile time: 7/12/2010 18:00:00 [07/24/2010 13:47:30]
system image file is: bootflash:/n7000-s1-dk9.5.0.3.bin
system compile time: 7/12/2010 18:00:00 [07/24/2010 15:21:35]


Hardware
cisco Nexus7000 C7018 (18 Slot) Chassis (\"Supervisor module-1X\")
Intel(R) Xeon(R) CPU with 4130100 kB of memory.
Processor Board ID JAF1423EFJC

Device name: rbx-97-n7
bootflash: 2000880 kB
slot0: 0 kB (expansion flash)

Kernel uptime is 67 day(s), 15 hour(s), 18 minute(s), 20 second(s)

Last reset at 357910 usecs after Wed Aug 25 21:37:28 2010

Reason: Reset triggered due to Switchover Request by User
System version: 5.0(3)
Service:

plugin
Core Plugin, Ethernet Plugin



CMP (Module 9) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.0(2) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 5/25/2010 13:00:00

CMP (Module 10) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.0(2) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 5/25/2010 13:00:00



Update(s):

Date: 2010-11-01 11:42:39 UTC
parfait. tout s'est bien deroulé.

nous avons perdu 2 packets ICMP. le trafic n'a pas été interompu.

--- rbx-97-n7.routers.chtix.eu ping statistics ---
3604 packets transmitted, 3602 received, 0% packet loss, time 3641598ms
rtt min/avg/max/mdev = 4.027/5.326/139.826/4.423 ms




Date: 2010-11-01 11:41:34 UTC
rbx-97-n7# 2010 Nov 1 13:40:38 rbx-97-n7 %$ VDC-1 %$ %CMPPROXY-2-LOG_CMP_UP: Connectivity Management processor(on module 10) is now UP

rbx-97-n7# sh ver
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_serie
s_home.html
Copyright (c) 2002-2010, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php

Software
BIOS: version 3.22.0
kickstart: version 5.1(1)
system: version 5.1(1)
BIOS compile time: 02/20/10
kickstart image file is: bootflash:///n7000-s1-kickstart.5.1.1.bin
kickstart compile time: 12/25/2020 12:00:00 [10/24/2010 12:25:25]
system image file is: bootflash:///n7000-s1-dk9.5.1.1.bin
system compile time: 9/2/2010 19:00:00 [10/24/2010 13:34:48]


Hardware
cisco Nexus7000 C7018 (18 Slot) Chassis (\"Supervisor module-1X\")
Intel(R) Xeon(R) CPU with 4109596 kB of memory.
Processor Board ID JAF1423EFEL

Device name: rbx-97-n7
bootflash: 2029608 kB
slot0: 0 kB (expansion flash)

Kernel uptime is 0 day(s), 0 hour(s), 48 minute(s), 51 second(s)

Last reset
Reason: Unknown
System version: 5.0(3)
Service:

plugin
Core Plugin, Ethernet Plugin


CMP (Module 10) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.1(1) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 9/2/2010 19:00:00

CMP (Module 9) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.1(1) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 9/2/2010 19:00:00

rbx-97-n7# sh redundancy status
Redundancy mode
---------------
administrative: HA
operational: HA

This supervisor (sup-10)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby

Other supervisor (sup-9)
------------------------
Redundancy state: Standby

Supervisor state: HA standby
Internal state: HA standby

System start time: Wed Jul 21 00:19:40 2010

System uptime: 103 days, 19 hours, 17 minutes, 27 seconds
Kernel uptime: 0 days, 0 hours, 49 minutes, 30 seconds
Active supervisor uptime: 0 days, 0 hours, 44 minutes, 0 seconds


Date: 2010-11-01 11:40:11 UTC
CMP (Module 10) no response
Displaying Cached Info...
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.0(2) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 5/25/2010 13:00:00

CMP (Module 9) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.1(1) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 9/2/2010 19:00:00


Date: 2010-11-01 11:39:42 UTC
rbx-97-n7# reload cmp module 10
This command will reload the CMP on the supervisor in slot 10. Continue (y/n)? [no] yes
rbx-97-n7#
rbx-97-n7#
rbx-97-n7# reload cmp module 10
This command will reload the CMP on the supervisor in slot 10. Continue (y/n)? [no] y
rbx-97-n7#
rbx-97-n7#
rbx-97-n7#

rbx-97-n7# system switchover 2010 Nov 1 13:39:12 rbx-97-n7 %$ VDC-1 %$ %CMPPROXY-2-LOG_CMP_WENT_DOWN: Connectivity Management processor (on module 10) went DOWN
^C
rbx-97-n7# 2010 Nov 1 13:39:14 rbx-97-n7 %$ VDC-1 %$ %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 9) is now UP


Date: 2010-11-01 11:38:20 UTC
rbx-97-n7(config)# poweroff module 9
powering down supervisor module is not supported

la fete ...

Date: 2010-11-01 11:37:10 UTC
rbx-97-n7# reload cmp module 9
This command will reload the CMP on the supervisor in slot 9. Continue (y/n)? [no]
rbx-97-n7# reload cmp module 9
This command will reload the CMP on the supervisor in slot 9. Continue (y/n)? [no] yes
rbx-97-n7#
rbx-97-n7# reload cmp module 9
This command will reload the CMP on the supervisor in slot 9. Continue (y/n)? [no] y
rbx-97-n7#

Date: 2010-11-01 11:36:03 UTC
c'est parti pour les redemarrages de sup

rbx-97-n7# reload cmp module 9
This command will reload the CMP on the supervisor in slot 9. Continue (y/n)? [no] y
rbx-97-n7#
rbx-97-n7# 2010 Nov 1 13:35:30 rbx-97-n7 %CMPPROXY-STANDBY-2-LOG_CMP_WENT_DOWN: Connectivity Management processor (on module 9) went DOWN


Date: 2010-11-01 11:16:42 UTC
Module 9: Upgrading CMP image.
Warning: please do not reload or power cycle CMP module at this time.
[####################] 100% -- SUCCESS

Recommended action::
\"Please reload CMP(s) manually to have it run in the newer version.\".

Install has been successful.

User Access Verification


Date: 2010-11-01 11:12:22 UTC
Module 10: Upgrading CMP image.
Warning: please do not reload or power cycle CMP module at this time.
[# ] 0%
[####################] 100% -- SUCCESS

Module 9: Upgrading CMP image.
Warning: please do not reload or power cycle CMP module at this time.
[# ] 0%

Date: 2010-11-01 11:09:27 UTC
Module 10: Upgrading CMP image.
Warning: please do not reload or power cycle CMP module at this time.
[# ] 0%


Date: 2010-11-01 11:08:58 UTC
2010 Nov 1 13:06:35 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 3 started
2010 Nov 1 13:06:35 rbx-97-n7 %SYSMGR-SLOT3-5-LC_UPGRADE_START: Starting linecard upgrade
2010 Nov 1 13:06:41 rbx-97-n7 %MRIB-3-UNKNOWN_MFDM_OPC: mrib [4527] mrib_mfdm_main(): reeceived unknown opcode 185
2010 Nov 1 13:07:05 rbx-97-n7 %SYSMGR-SLOT3-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2010 Jan 1 01:00:23 rbx-97-n7 %SYSMGR-SLOT3-4-READCONF_STARTED: Configuration update started (PID 1899).
2010 Nov 1 13:07:50 rbx-97-n7 %SYSMGR-SLOT3-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1900).
2010 Nov 1 13:07:53 rbx-97-n7 %SYSMGR-SLOT3-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2010 Nov 1 13:07:55 rbx-97-n7 %BIOS_DAEMON-SLOT3-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2010 Nov 1 13:08:16 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 3 ended
2010 Nov 1 13:08:16 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 3 current-status is MOD_STATUS_ONLINE/OK
2010 Nov 1 13:08:16 rbx-97-n7 %MODULE-5-MOD_OK: Module 3 is online (serial: JAF1406ALGG)
2010 Nov 1 13:08:16 rbx-97-n7 %SYSMGR-SLOT3-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2010 Nov 1 13:08:17 rbx-97-n7 %ELTMC-SLOT3-2-ELTMC_INTERFACE_INTERNAL_ERROR: Internal error: Ethernet1/3:Interface mode change not allowed when it is up, collect output of show tech-support eltm
2010 Nov 1 13:08:26 rbx-97-n7 %MRIB-3-UNKNOWN_MFDM_OPC: mrib [4527] mrib_mfdm_main(): reeceived unknown opcode 185


Date: 2010-11-01 11:07:14 UTC
3 32 10 Gbps Ethernet Module N7K-M132XP-12 upgrading


Date: 2010-11-01 11:07:01 UTC
2010 Nov 1 13:05:05 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 2 started
2010 Nov 1 13:05:05 rbx-97-n7 %SYSMGR-SLOT2-5-LC_UPGRADE_START: Starting linecard upgrade
2010 Nov 1 13:05:11 rbx-97-n7 %SYSMGR-SLOT2-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2010 Jan 1 01:00:20 rbx-97-n7 %SYSMGR-SLOT2-4-READCONF_STARTED: Configuration update started (PID 1898).
2010 Nov 1 13:05:49 rbx-97-n7 %SYSMGR-SLOT2-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1899).
2010 Nov 1 13:05:53 rbx-97-n7 %SYSMGR-SLOT2-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2010 Nov 1 13:05:54 rbx-97-n7 %BIOS_DAEMON-SLOT2-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2010 Nov 1 13:06:09 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 2 ended
2010 Nov 1 13:06:09 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 2 current-status is MOD_STATUS_ONLINE/OK
2010 Nov 1 13:06:09 rbx-97-n7 %MODULE-5-MOD_OK: Module 2 is online (serial: JAF1426AGCQ)
2010 Nov 1 13:06:09 rbx-97-n7 %SYSMGR-SLOT2-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.


Date: 2010-11-01 11:06:05 UTC
2 8 10 Gbps Ethernet XL Module N7K-M108X2-12L upgrading


Date: 2010-11-01 11:05:23 UTC
2010 Nov 1 13:03:37 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 1 started
2010 Nov 1 13:03:37 rbx-97-n7 %SYSMGR-SLOT1-5-LC_UPGRADE_START: Starting linecard upgrade
2010 Nov 1 13:03:43 rbx-97-n7 %SYSMGR-SLOT1-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2010 Jan 1 01:00:19 rbx-97-n7 %SYSMGR-SLOT1-4-READCONF_STARTED: Configuration update started (PID 1898).
2010 Nov 1 13:04:20 rbx-97-n7 %SYSMGR-SLOT1-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1899).
2010 Nov 1 13:04:22 rbx-97-n7 %SYSMGR-SLOT1-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2010 Nov 1 13:04:24 rbx-97-n7 %BIOS_DAEMON-SLOT1-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2010 Nov 1 13:04:39 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 1 ended
2010 Nov 1 13:04:39 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_ONLINE/OK
2010 Nov 1 13:04:39 rbx-97-n7 %MODULE-5-MOD_OK: Module 1 is online (serial: JAF1426EBKE)
2010 Nov 1 13:04:38 rbx-97-n7 %SYSMGR-SLOT1-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2010 Nov 1 13:04:51 rbx-97-n7 %MRIB-3-UNKNOWN_MFDM_OPC: mrib [4527] mrib_mfdm_main(): reeceived unknown opcode 185


Date: 2010-11-01 11:04:30 UTC
rbx-97-n7# sh module
Mod Ports Module-Type Model Status
--- ----- -------------------------------- ------------------ ------------
1 48 1000 Mbps Optical Ethernet XL Mo N7K-M148GS-11L upgrading


Date: 2010-11-01 11:04:12 UTC
Nov 1 12:03:59 rbx-97-n7.routers..ovh.net : 2010 Nov 1 13:03:37 CEST: %MODULE-5-STANDBY_SUP_OK: Supervisor 9 is standby
Nov 1 12:03:59 rbx-97-n7.routers..ovh.net : 2010 Nov 1 13:03:37 CEST: %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 1 started
Nov 1 12:03:59 rbx-97-n7.routers..ovh.net : 2010 Nov 1 13:03:37 CEST: %SYSMGR-SLOT1-5-LC_UPGRADE_START: Starting linecard upgrade
Nov 1 12:04:05 rbx-97-n7.routers..ovh.net : 2010 Nov 1 13:03:43 CEST: %SYSMGR-SLOT1-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade


Date: 2010-11-01 11:03:54 UTC
rbx-97-n7# sh redundancy status
Redundancy mode
---------------
administrative: HA
operational: Warm

This supervisor (sup-10)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby

Other supervisor (sup-9)
------------------------
Redundancy state: Standby

Supervisor state: HA standby
Internal state: HA synchronization in progress



Date: 2010-11-01 11:03:01 UTC
2010 Nov 1 13:01:40 rbx-97-n7 %MRIB-3-UNKNOWN_MFDM_OPC: mrib [4527] mrib_mfdm_main(): reeceived unknown opcode 185
2010 Nov 1 13:02:14 rbx-97-n7 %MRIB-3-UNKNOWN_MFDM_OPC: mrib [4527] mrib_mfdm_main(): reeceived unknown opcode 185
rbx-97-n7# 2010 Nov 1 13:02:37 rbx-97-n7 %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 9) is now UP


Date: 2010-11-01 11:02:01 UTC
rbx-97-n7# sh redundancy status
Redundancy mode
---------------
administrative: HA
operational: None

This supervisor (sup-10)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with no standby

Other supervisor (sup-9)
------------------------
Redundancy state: Initializing

Supervisor state: N/A
Internal state: N/A

System start time: Wed Jul 21 00:19:40 2010

System uptime: 103 days, 18 hours, 36 minutes, 29 seconds
Kernel uptime: 0 days, 0 hours, 8 minutes, 32 seconds
Active supervisor uptime: 0 days, 0 hours, 3 minutes, 2 seconds


Date: 2010-11-01 11:00:11 UTC
la carte 10 est devenu active et a ordonné à la carte 9 le reload

mais c'est bizarre. on est sur la version 5.0(2) sur la 10 alors
qu'on a bien booté en 5.1(1)

CMP (Module 10) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.0(2) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 5/25/2010 13:00:00


Date: 2010-11-01 10:58:57 UTC
rbx-97-n7# 2010 Nov 1 12:56:49 rbx-97-n7 %$ VDC-1 %$ %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 10) is now UP
2010 Nov 1 12:56:52 rbx-97-n7 %$ VDC-1 %$ %IDEHSD-STANDBY-2-MOUNT: logflash: online
Reloading the su
User Access Verification
rbx-97-n7 login: writing reset reason 7, SAP(93): Swover due to install

NX7 SUP Ver 3.22.0
Serial Port Parameters from CMOS
PMCON_1: 0x200
PMCON_2: 0x0
PMCON_3: 0x3a
PM1_STS: 0x101
Performing Memory Detection and Testing
Total mem found : 4096 MB
Performing memory test... Passed.
NumCpus = 2.
Status 61: PCI DEVICES Enumeration Started
Status 62: PCI DEVICES Enumeration Ended
Status 9F: Dispatching Drivers
Status 9E: IOFPGA Found
Status 9A: Booting From Primary ROM
Status 98: Found Cisco IDE
Status 98: Found Cisco IDE
Status 90: Loading Boot Loader

Reset Reason Registers: 0x1 0x0
Filesystem type is ext2fs, partition type 0x83


GNU GRUB version 0.97

Autobooting bootflash:/n7000-s1-kickstart.5.1.1.bin bootflash:/n7000-s1-dk9.5.1
.1.bin...
Filesystem type is ext2fs, partition type 0x83
Booting kickstart image: bootflash:/n7000-s1-kickstart.5.1.1.bin....
...............................................................................
....................Image verification OK

INIT: version 2
Checking all filesystems..r.r.r..

Date: 2010-11-01 10:58:07 UTC
2010 Nov 1 12:57:19 rbx-97-n7 %$ VDC-1 %$ Nov 1 12:57:19 %KERN-2-SYSTEM_MSG: Switchover started by redundancy driver - kernel
2010 Nov 1 12:57:19 rbx-97-n7 %$ VDC-1 %$ %SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active (pre-start phase).
2010 Nov 1 12:57:19 rbx-97-n7 %$ VDC-1 %$ %SYSMGR-2-HASWITCHOVER_START: Supervisor 10 is becoming active.
2010 Nov 1 12:57:20 rbx-97-n7 %$ VDC-1 %$ %SYSMGR-2-SWITCHOVER_OVER: Switchover completed.


Date: 2010-11-01 10:57:48 UTC
Module 10: Waiting for module online.
-- SUCCESS

Notifying services about the switchover.
[####################] 100% -- SUCCESS


\"Switching over onto standby\".


Date: 2010-11-01 10:57:08 UTC
2010 Nov 1 12:56:49 rbx-97-n7 %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 10) is now UP
2010 Nov 1 12:56:52 rbx-97-n7 %IDEHSD-STANDBY-2-MOUNT: logflash: online


Date: 2010-11-01 10:56:41 UTC
Nov 1 11:56:30 rbx-97-n7.fr.eu : 2010 Nov 01 12:56:08 CEST: %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting...


Date: 2010-11-01 10:56:05 UTC
rbx-97-n7(standby)#
rbx-97-n7(standby)#
NX7 SUP Ver 3.22.0
Serial Port Parameters from CMOS
PMCON_1: 0x200
PMCON_2: 0x0
PMCON_3: 0x3a
PM1_STS: 0x101
Performing Memory Detection and Testing
Total mem found : 4096 MB
Performing memory test... Passed.
NumCpus = 2.
Status 61: PCI DEVICES Enumeration Started
Status 62: PCI DEVICES Enumeration Ended
Status 9F: Dispatching Drivers
Status 9E: IOFPGA Found
Status 9A: Booting From Primary ROM
Status 98: Found Cisco IDE
Status 98: Found Cisco IDE
Status 90: Loading Boot Loader

Reset Reason Registers: 0x0 0x8
Filesystem type is ext2fs, partition type 0x83


GNU GRUB version 0.97

Autobooting bootflash:/n7000-s1-kickstart.5.1.1.bin bootflash:/n7000-s1-dk9.5.1
.1.bin...
Filesystem type is ext2fs, partition type 0x83
Booting kickstart image: bootflash:/n7000-s1-kickstart.5.1.1.bin....
...............................................................................
....................Image verification OK

INIT: version 2
Checking all filesystems..r.r.r..r done.
Loading system software
/bootflash//n7000-s1-dk9.5.1.1.bin read done
Uncompressing system image: bootflash:/n7000-s1-dk9.5.1.1.bin Mon Nov 1 12:54:45 CEST 2010
blogger: nothing to do.

..done Mon Nov 1 12:54:48 CEST 2010
Load plugins that defined in image conf: /isan/plugin_img/img.conf
Loading plugin 0: core_plugin...
num srgs 1
0: swid-core-supdc3, swid-core-supdc3
num srgs 1
0: swid-supdc3-ks, swid-supdc3-ks
INIT: Entering runlevel: 3


Continuing with installation, please wait


Date: 2010-11-01 10:55:24 UTC
Nov 1 11:51:28 rbx-97-n7.fr.eu : 2010 Nov 01 12:51:06 CEST: %LIBSYSMGR-3-HASEQNO_SYNC_FAILED: Unable to sync HA sequence number (0x45AE32B0) for service \"nfm\" (PID 4901): Connection timed out (110).
Nov 1 11:51:30 rbx-97-n7.fr.eu : 2010 Nov 01 12:51:08 CEST: %PLATFORM-2-MOD_REMOVE: Module 10 removed (Serial number JAF1423EFEL)
Posted Nov 01, 2010 - 10:37 UTC