OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
upgrade asr 9010
Scheduled Maintenance Report for Network & Infrastructure
Completed
Lors de mise à jour du ASR 9010, nous avons un jolie bug:

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Wed Nov 3 23:49:57.264 UTC
Install operation 43 '(admin) install commit' started by user '' via CLI at 23:49:57 UTC Wed Nov 03 2010.
Error: Cannot proceed with the operation because the upgrade package disk0:asr9k-upgrade-p-4.0.0 is present on boot disk.
Error:
Error: The disk0:asr9k-upgrade-p-4.0.0 package should only be used when upgrading from software versions prior to 4.0.0. Once the upgrade is complete, it should be immediately deactivated and removed. No
Error: further install operations will be allowed until this is completed.
Error:
Error: Remove the package disk0:asr9k-upgrade-p-4.0.0 from the entire router by executing the 'install remove disk0:asr9k-upgrade-p-4.0.0' command in admin mode.
Error: No further install operations will be allowed until this is completed.
Install operation 43 failed at 23:49:58 UTC Wed Nov 03 2010.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#

Le routeur ne veut pas installer la version 4.0.0 car il faut
pas installer asr9k-upgrade-p-4.0.0 (comme bien stipuler dans
la release note).

Par contre:

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.0 synchronous
Wed Nov 3 23:44:39.750 UTC
Install operation 38 '(admin) install remove disk0:asr9k-upgrade-p-4.0.0 synchronous' started by user '' via CLI at 23:44:40 UTC Wed Nov 03 2010.
Error: The following packages cannot be removed because they are part of the active software:
Error: disk0:asr9k-doc-4.0.0
Error: disk0:asr9k-adv-video-4.0.0
Error: disk0:asr9k-sbc-4.0.0
Error: disk0:asr9k-k9sec-4.0.0
Error: disk0:asr9k-diags-4.0.0
Error: disk0:asr9k-mgbl-4.0.0
Error: disk0:asr9k-mcast-4.0.0
Error: disk0:asr9k-mpls-4.0.0
Error: disk0:asr9k-rout-4.0.0
Error: disk0:asr9k-fwdg-4.0.0
Error: disk0:asr9k-lc-4.0.0
Error: disk0:asr9k-admin-4.0.0
Error: Suggested steps to resolve this:
Error: - check the name of the packages being removed.
Error: - check the set of active packages using '(admin) show install active'.
Install operation 38 failed at 23:44:40 UTC Wed Nov 03 2010.

C'est à dire qu'il ne veut pas l'effacer :)



Update(s):

Date: 2010-11-04 07:19:55 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#sh install active
Thu Nov 4 07:19:36.871 UTC
Secure Domain Router: Owner

Node 0/RSP0/CPU0 [RP] [SDR: Owner]
Boot Device: disk0:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/mbiasr9k-rp.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-doc-p-4.0.0
disk0:asr9k-k9sec-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mgbl-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

Node 0/RSP1/CPU0 [RP] [SDR: Owner]
Boot Device: disk0:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/mbiasr9k-rp.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-doc-p-4.0.0
disk0:asr9k-k9sec-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mgbl-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

Node 0/0/CPU0 [LC] [SDR: Owner]
Boot Device: mem:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/lc/mbiasr9k-lc.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

Node 0/1/CPU0 [LC] [SDR: Owner]
Boot Device: mem:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/lc/mbiasr9k-lc.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

Node 0/2/CPU0 [LC] [SDR: Owner]
Boot Device: mem:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/lc/mbiasr9k-lc.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

Node 0/3/CPU0 [LC] [SDR: Owner]
Boot Device: mem:
Boot Image: /disk0/asr9k-os-mbi-4.0.0/lc/mbiasr9k-lc.vm
Active Packages:
disk0:asr9k-mini-p-4.0.0
disk0:asr9k-mpls-p-4.0.0
disk0:asr9k-mcast-p-4.0.0

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#

fini :)

Date: 2010-11-04 07:15:50 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install commit
Thu Nov 4 07:13:51.533 UTC
Install operation 54 '(admin) install commit' started by user 'octave' via CLI at 07:13:51 UTC Thu Nov 04 2010.
Install operation 54 completed successfully at 07:13:54 UTC Thu Nov 04 2010.


ça a l'air magique

Date: 2010-11-03 23:58:58 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install add source asr9k-doc-p.pie-4.0.0 asr9k-k9sec-p.pie-4.0.0 asr9k-mcast-p.pie-4.0.0 asr9k-mgbl-p.pie-4.0.0 asr9kmini-p.pie-4.0.0
asr9k-mpls-
Install operation 46 '(admin) install add source asr9k-doc-p.pie-4.0.0 asr9k-k9sec-p.pie-4.0.0 asr9k-mcast-p.pie-4.0.0 asr9k-mgbl-p.pie-4.0.0 asr9k-mini-p.pie-4.0.0
asr9k-mpls-p.pie-4.0.0 synchronous' started by user '' via CLI at 23:56:48 UTC Wed Nov 03 2010.

on attend le chargement des fichiers


Date: 2010-11-03 23:55:53 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.0 synchronous
Wed Nov 3 23:55:04.241 UTC
Install operation 45 '(admin) install remove disk0:asr9k-upgrade-p-4.0.0 synchronous' started by user 'octave' via CLI at 23:55:04 UTC Wed Nov 03 2010.
Info: This operation will remove the following packages:
Info: disk0:asr9k-doc-4.0.0
Info: disk0:asr9k-adv-video-4.0.0
Info: disk0:asr9k-sbc-4.0.0
Info: disk0:asr9k-k9sec-4.0.0
Info: disk0:asr9k-diags-4.0.0
Info: disk0:asr9k-mgbl-4.0.0
Info: disk0:asr9k-mcast-4.0.0
Info: disk0:asr9k-mpls-4.0.0
Info: disk0:asr9k-rout-4.0.0
Info: disk0:asr9k-fwdg-4.0.0
Info: disk0:asr9k-lc-4.0.0
Info: disk0:asr9k-admin-4.0.0
Info: disk0:asr9k-upgrade-p-4.0.0
Info: After this install remove the following install rollback point will no longer be reachable, as the required packages will not be present:
Info: 30
Proceed with removing these packages? [confirm]
Install operation 45 completed successfully at 23:55:23 UTC Wed Nov 03 2010.
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#

Date: 2010-11-03 23:53:18 UTC
Suite à la desactivation (c'est pas dans la doc), on peut effacer
mais tout ...

RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.0 synchronous
Wed Nov 3 23:47:27.954 UTC
Install operation 42 '(admin) install remove disk0:asr9k-upgrade-p-4.0.0 synchronous' started by user 'octave' via CLI at 23:47:28 UTC Wed Nov 03 2010.
Info: This operation will remove the following packages:
Info: disk0:asr9k-doc-4.0.0
Info: disk0:asr9k-adv-video-4.0.0
Info: disk0:asr9k-sbc-4.0.0
Info: disk0:asr9k-k9sec-4.0.0
Info: disk0:asr9k-diags-4.0.0
Info: disk0:asr9k-mgbl-4.0.0
Info: disk0:asr9k-mcast-4.0.0
Info: disk0:asr9k-mpls-4.0.0
Info: disk0:asr9k-rout-4.0.0
Info: disk0:asr9k-fwdg-4.0.0
Info: disk0:asr9k-lc-4.0.0
Info: disk0:asr9k-admin-4.0.0
Info: disk0:asr9k-upgrade-p-4.0.0
Info: After this install remove the following install rollback point will no longer be reachable, as the required packages will not be present:
Info: 30
Proceed with removing these packages? [confirm]


Date: 2010-11-03 23:52:08 UTC
RP/0/RSP0/CPU0:rbx-g1-a9(admin)#install deactivate disk0:asr9k-upgrade-p-4.0.0 synchronous
Wed Nov 3 23:45:01.465 UTC
Install operation 39 '(admin) install deactivate disk0:asr9k-upgrade-p-4.0.0 synchronous' started by user '' via CLI at 23:45:01 UTC Wed Nov 03 2010.
Info: Install Method: Parallel Process Restart
Info: The changes made to software configurations will not be persistent across system reloads. Use the command '(admin) install commit' to make changes persistent.
Info: Please verify that the system is consistent following the software change using the following commands:
Info: show system verify
Info: install verify packages
Install operation 39 completed successfully at 23:46:25 UTC Wed Nov 03 2010.
Posted Nov 03, 2010 - 23:51 UTC