FS#4793 — th1-1-6k

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Crash. On le reload

Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302106: Nov 5 13:54:51 GMT: %SYS-2-MALLOCFAIL: Memory allocation of 65536 bytes failed from 0x410433D8, alignment 8
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302107: Pool: Processor Free: 35122824 Cause: Memory fragmentation
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302108: Alternate Pool: None Free: 0 Cause: No Alternate pool
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302109: -Process= "IP RIB Update", ipl= 0, pid= 164
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302110: -Traceback= 4102AD28 41030958 410433E0 413C2D10 42289224 406417AC 42305768 409D2680 40983230 40983350
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302111: Nov 5 13:54:51 GMT: %FIB-3-NORPXDRQELEMS: Exhausted XDR queuing elements while preparing message for slot/cpu 3/0
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302112: -Process= "IP RIB Update", ipl= 0, pid= 164
Nov 5 13:55:20 80G.th1-1-6k.routers.ovh.net 302113: -Traceback= 413C2DE0 42289224 406417AC 42305768 409D2680 40983230 40983350

Date:  Friday, 12 November 2010, 00:04AM
Reason for closing:  Done
Comment by OVH - Friday, 05 November 2010, 13:57PM

Nov 5 13:55:31 80G.th1-1-6k.routers.ovh.net 302114: Nov 5 13:54:57 GMT: %FIB-3-NOMEM: Malloc Failure, disabling DCEF


Comment by OVH - Friday, 05 November 2010, 15:22PM

fixé


Comment by OVH - Friday, 05 November 2010, 17:08PM

optique remplacé dans port 5/2


Comment by OVH - Tuesday, 09 November 2010, 08:33AM

Nov 9 08:32:48 80G.th1-1-6k.routers.ovh.net 971: Nov 9 08:32:24 GMT: %FIB-3-NOMEM: Malloc Failure, disabling CEF

on le reload


Comment by OVH - Tuesday, 09 November 2010, 08:57AM

C'est up.

On va ajouter un 2ème routeur à th1-1-6k

Aussi on change la maniere de prendre les full-routes