FS#4858 — rbx-22

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
Le routeur a fait un failover
Date:  Saturday, 20 November 2010, 11:25AM
Reason for closing:  Done
Comment by OVH - Saturday, 20 November 2010, 10:44AM

Nov 20 08:15:40 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:16 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 6 (asic=1, srcidx=0x341, seq=7)
Nov 20 08:15:40 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:17 %SYS-1-MOD_INVALIDSEQ:Bus asic invalid sequence occured on module 2 (asic=1, srcidx=0x341, seq=7)
Nov 20 08:15:40 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:17 %SYS-1-MOD_SEQERROR:Switching bus sequence error occurred on module 3
Nov 20 08:15:40 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:17 %SYS-1-MOD_SEQERROR:Switching bus sequence error occurred on module 4
Nov 20 08:15:41 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:17 %SYS-5-SUP_MODSBY:Module 1 is in standby mode
Nov 20 08:15:51 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:24 %SYS-3-MOD_PORTINTFOUTOFSYNC:Port Interface not in sync for Module 4
Nov 20 08:15:51 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:15:28 %SYS-3-MOD_PORTINTFOUTOFSYNC:Port Interface not in sync for Module 3
Nov 20 08:17:36 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:13 %SYS-5-SUP_MODSBY:Module 1 is in standby mode
Nov 20 08:18:04 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:41 %SYS-5-PORT_SSUPOK:Ports on standby supervisor (module 1) are up
Nov 20 08:18:04 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:41 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 1
Nov 20 08:18:08 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:45 %DTP-5-TRUNKPORTON:Port 1/1 has become dot1q trunk
Nov 20 08:18:08 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:45 %DTP-5-TRUNKPORTON:Port 1/2 has become dot1q trunk
Nov 20 08:18:10 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:17:47 %ETHC-5-PORTTOSTP:Port 1/1 joined bridge port 1/1,2/2
Nov 20 08:18:59 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:18:35 %SYS-5-MOD_OK:Module 15(WS-F6K-MSFC,SAD042203RS) is online

le failover s'est bien passé

par contre la carte #5 nous a posé les problemes

Nov 20 08:37:01 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:36:38 %SYS-5-MOD_PWRON:Module 5 powered up
Nov 20 08:37:01 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:36:38 %SYS-5-MOD_INSERT:Module 5 has been inserted
Nov 20 08:54:56 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:54:34 %SYS-4-SUPERVISOR_ERR:Forwarding engine IP checksum error counter = 4919
Nov 20 08:58:42 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:58:19 %SYS-5-MOD_REMOVE:Module 5 has been removed
Nov 20 09:00:07 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:59:43 %SYS-5-MOD_PWRON:Module 5 powered up
Nov 20 09:00:07 rbx-22-c1.routers.ovh.net 2010 Nov 20 07:59:43 %SYS-5-MOD_INSERT:Module 5 has been inserted
Nov 20 09:00:23 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:00 %SYS-5-MOD_OK:Module 5(WS-X6408-GBIC,SAD03383131) is online
Nov 20 09:00:23 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:00 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 5
Nov 20 09:00:28 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:04 %DTP-5-TRUNKPORTON:Port 5/1 has become dot1q trunk
Nov 20 09:00:28 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:05 %DTP-5-TRUNKPORTON:Port 5/2 has become dot1q trunk
Nov 20 09:00:30 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:07 %ETHC-5-PORTTOSTP:Port 5/1 joined bridge port 1/1,2/2,5/1
Nov 20 09:00:30 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:07 %ETHC-5-PORTTOSTP:Port 5/2 joined bridge port 1/2,2/1,5/2
Nov 20 09:00:45 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:22 %DTP-5-TRUNKPORTON:Port 5/8 has become dot1q trunk
Nov 20 09:00:57 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:00:34 %ETHC-5-PORTTOSTP:Port 5/8 joined bridge port 5/8
Nov 20 09:16:56 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:16:32 %SYS-5-MOD_REMOVE:Module 5 has been removed
Nov 20 09:17:50 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:17:27 %SYS-5-MOD_PWRON:Module 5 powered up
Nov 20 09:17:50 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:17:27 %SYS-5-MOD_INSERT:Module 5 has been inserted
Nov 20 09:18:07 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:17:44 %SYS-5-MOD_OK:Module 5(WS-X6408-GBIC,SAD03383131) is online
Nov 20 09:18:07 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:17:44 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 5
Nov 20 09:22:08 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:21:45 %SYS-5-MOD_REMOVE:Module 5 has been removed
Nov 20 09:23:03 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:22:40 %SYS-5-MOD_PWRON:Module 5 powered up
Nov 20 09:23:03 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:22:40 %SYS-5-MOD_INSERT:Module 5 has been inserted
Nov 20 09:23:20 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:22:57 %SYS-5-MOD_OK:Module 5(WS-X6408-GBIC,JAB034107BD) is online
Nov 20 09:23:20 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:22:57 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 5
Nov 20 09:23:24 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:23:01 %DTP-5-TRUNKPORTON:Port 5/2 has become dot1q trunk
Nov 20 09:23:25 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:23:02 %DTP-5-TRUNKPORTON:Port 5/1 has become dot1q trunk
Nov 20 09:23:26 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:23:03 %ETHC-5-PORTTOSTP:Port 5/2 joined bridge port 1/2,2/1,5/2
Nov 20 09:23:27 rbx-22-c1.routers.ovh.net 2010 Nov 20 08:23:04 %ETHC-5-PORTTOSTP:Port 5/1 joined bridge port 1/1,2/2,5/1

nous avons changé la carte. le probleme est fixé.