N5/N56/N6 ISSU campain
Scheduled Maintenance Report for Network & Infrastructure
Completed
Details
Description:
An upgrade campaign is launched on all Nexus 5000/5600/6000 of Baremetal aggregator switches.

Impact:
None, upgrade is done trough ISSU (In Services Software Upgrade)

Duration:
Each couples of Nexus 5000/5600/6000 take 1h30-3h00 to be fully upgraded.

Maintenance date:

Date: 29th March.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs-10a/b-n5
bhs1-11a/b-n5
bhs1-12a/b-n5
bhs2-11a/b-n6

Date: 29th March.
Time: 10:00PM - 01:00AM (Paris time) on Gravelines, FR datacenter:
gra1-15a/b-n6
gra1-16a/b-n6
gra1-20a/b-n6
gra1-21a/b-n56

********************************************************************************

Date: 30th March.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs2-15a/b-n6
bhs2-16a/b-n56
bhs2-17a/b-n56
bhs2-18a/b-n56

Date: 30th March.
Time: 10:00PM - 01:00AM (Paris time) on Gravelines, FR datacenter:
gra1-23a/b-n56
gra1-24a/b-n56
gra1-25a/b-n56
gra1-26a/b-n56

********************************************************************************
Date: 31st March.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs2-19a/b-n56
bhs2-20a/b-n56
bhs4-12a/b-n56
sw.192.95.32.248/249-n5

Date: 31st March.
Time: 10:00PM - 01:00AM (Paris time) on Gravelines, FR datacenter:
gra1-27a/b-n56
gra1-30a/b-n56
gra2-17a/b-n56
gra2-21a/b-n56

********************************************************************************

Date: 1st April.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs4-16a/b-n56
bhs4-17a/b-n56
sw.142.4.216.248/249-n5

Date: 1st April.
Time: 10:00PM - 01:00AM (Paris time) on Londres, LON datacenter:
lon1-eri1-11a/b-n56
lon1-eri1-12a/b-n56
lon1-eri1-13a-n56

********************************************************************************

Update(s):

Date: 2021-04-01 23:00:30 UTC
The upgrades of lon1-eri1-11a/b-n56, lon1-eri1-12a/b-n56, lon1-eri1-13a/b-n56are successfully completed.

Date: 2021-04-01 20:00:31 UTC
I am starting upgrades of lon1-eri1-11a/b-n56, lon1-eri1-12a/b-n56, lon1-eri1-13a/b-n56. No impact.

Date: 2021-04-01 09:05:12 UTC
Date: 1st April.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs4-16a/b-n56 == Done
bhs4-17a/b-n56 == Done
sw.142.4.216.248/249-n5 == Done


Date: 2021-03-31 20:00:46 UTC
I am starting upgrade of gra1-27a/b-n56, gra1-30a/b-n56, gra2-17a/b-n56, gra2-21a/b-n56. No impact is expected.

Date: 2021-03-31 11:54:43 UTC
Date: 31st March.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter
bhs2-19a/b-n56 == Done
bhs2-20a/b-n56 == Done
bhs4-12a/b-n56 == Done
sw.192.95.32.248/249-n5 == Done

Date: 2021-03-31 01:17:21 UTC
upgrades of gra1-23a/b-n56, gra1-24a/b-n56, gra1-25a/b-n56 are completed
upgrade of gra1-26a/b-n56 is postponed for later date

Date: 2021-03-30 20:01:01 UTC
I am starting upgrades of gra1-23a/b-n56, gra1-24a/b-n56, gra1-25a/b-n56, gra1-26a/b-n56. No impact is expected. NETCHANGE-1218


Date: 2021-03-30 10:54:47 UTC
Date: 30th March.
Time: 02:00AM - 06:00AM (Montreal time) on Beauharnois, CA Datacenter

bhs2-16a/b-n56 == Done
bhs2-17a/b-n56 == Done
bhs2-18a/b-n56 == Done

Date: 2021-03-30 01:06:11 UTC
the upgrade \"gra1-15a/b-n6\", \"gra1-16a/b-n6\", \"gra1-20a/b-n6\" is completed.
upgrade of \"gra1-21a/b-n56\" is postponed

Date: 2021-03-29 20:02:10 UTC
Starting upgrades of \"gra1-15a/b-n6\", \"gra1-16a/b-n6\", \"gra1-20a/b-n6\", \"gra1-21a/b-n56\". No impact expected

Date: 2021-03-29 14:38:29 UTC
Attached to https://travaux.ovh.net/?do=details&id=49707
Posted Mar 25, 2021 - 15:09 UTC