FS#5008 — rbx-s2-6k
Attached to Project— Reseau Internet et Baies
| Maintenance | |
| Tout le réseau | |
| CLOSED | |
![]() |
bizarre.
Jan 7 11:34:43 GMT: %DIAG-SP-3-TEST_FAIL: Module 9: TestMacNotification{ID=14} has failed. Error code = 0x3B (DIAG_L2_INDEX_MISMATCH_ERROR)
Jan 7 11:34:43 GMT: %C6KERRDETECT-SP-2-SWBUSSTALL: The switching bus is experiencing stall for 3 seconds
Jan 7 11:34:44 GMT: %C6KERRDETECT-SP-2-SWBUSSTALL_RECOVERED: The switching bus stall is recovered and data traffic switching continues
*Mar 1 00:00:02.295: DaughterBoard (Distributed Forwarding Card 3)
Firmware compiled 22-Apr-10 14:56 by integ Build [100]
Jan 7 10:36:02.569: %SYS-DFC11-5-RESTART: System restarted --
Cisco IOS Software, c6lc2 Software (c6lc2-SP-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 16-Jul-10 19:50 by prod_rel_team
Jan 7 10:36:02.577: DFC11: Currently running ROMMON from S (Gold) region
Jan 7 11:36:08 GMT: %DIAG-SP-6-RUN_MINIMUM: Module 11: Running Minimal Diagnostics...
Jan 7 11:37:49 GMT: %DIAG-SP-6-DIAG_OK: Module 11: Passed Online Diagnostics
Jan 7 11:37:52 GMT: %OIR-SP-6-INSCARD: Card inserted in slot 11, interfaces are now online
Date: Monday, 07 February 2011, 15:18PMJan 7 11:34:43 GMT: %DIAG-SP-3-TEST_FAIL: Module 9: TestMacNotification{ID=14} has failed. Error code = 0x3B (DIAG_L2_INDEX_MISMATCH_ERROR)
Jan 7 11:34:43 GMT: %C6KERRDETECT-SP-2-SWBUSSTALL: The switching bus is experiencing stall for 3 seconds
Jan 7 11:34:44 GMT: %C6KERRDETECT-SP-2-SWBUSSTALL_RECOVERED: The switching bus stall is recovered and data traffic switching continues
*Mar 1 00:00:02.295: DaughterBoard (Distributed Forwarding Card 3)
Firmware compiled 22-Apr-10 14:56 by integ Build [100]
Jan 7 10:36:02.569: %SYS-DFC11-5-RESTART: System restarted --
Cisco IOS Software, c6lc2 Software (c6lc2-SP-M), Version 12.2(33)SXI4a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 16-Jul-10 19:50 by prod_rel_team
Jan 7 10:36:02.577: DFC11: Currently running ROMMON from S (Gold) region
Jan 7 11:36:08 GMT: %DIAG-SP-6-RUN_MINIMUM: Module 11: Running Minimal Diagnostics...
Jan 7 11:37:49 GMT: %DIAG-SP-6-DIAG_OK: Module 11: Passed Online Diagnostics
Jan 7 11:37:52 GMT: %OIR-SP-6-INSCARD: Card inserted in slot 11, interfaces are now online
Reason for closing: Done