FS#5073 — rbx-g2-a9

Attached to Project— Reseau Internet et Baies
Maintenance
Tout le réseau
CLOSED
100%
Nous allons mettre à jour le routeur rbx-g2-a9. Il ne dispose pas
de mise à jour à ISSU. Nous allons donc augmenter les poids OSPF
afin de ne pas prendre de trafic ce qui evitera de coupure dans
le trafic.
Date:  Thursday, 27 January 2011, 07:40AM
Reason for closing:  Done
Comment by OVH - Thursday, 27 January 2011, 06:55AM

64 bytes from rbx-g2-a9.routers.ovh.net (94.23.122.20): icmp_seq=139 ttl=252 time=11.8 ms

64 bytes from rbx-g2-a9.routers.ovh.net (94.23.122.20): icmp_seq=584 ttl=251 time=20.8 ms
64 bytes from rbx-g2-a9.routers.ovh.net (94.23.122.20): icmp_seq=585 ttl=251 time=4.53 ms


Comment by OVH - Thursday, 27 January 2011, 06:58AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install commit
Thu Jan 27 05:53:13.603 UTC
Install operation 15 '(admin) install commit' started by user 'octave' via CLI at 05:53:14 UTC Thu Jan 27 2011.
Error: Cannot proceed with the operation because the upgrade package disk0:asr9k-upgrade-p-4.0.1 is active.
Error:
Error: The disk0:asr9k-upgrade-p-4.0.1 package should only be used when upgrading from software versions prior to 4.0.0. Once the upgrade is complete, it should be immediately deactivated and removed. No
Error: further install operations will be allowed until this is completed.
Error:
Error: Deactivate the package disk0:asr9k-upgrade-p-4.0.1 from the entire router by executing the 'install deactivate disk0:asr9k-upgrade-p-4.0.1' command in admin mode.
Error: Remove the package disk0:asr9k-upgrade-p-4.0.1 from the entire router by executing the 'install remove disk0:asr9k-upgrade-p-4.0.1' command in admin mode.
Error: No further install operations will be allowed until this is completed.
Install operation 15 failed at 05:53:14 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install deactivate disk0:asr9k-upgrade-p-4.0.1
Thu Jan 27 05:53:25.050 UTC
Install operation 16 '(admin) install deactivate disk0:asr9k-upgrade-p-4.0.1' started by user 'octave' via CLI at 05:53:25 UTC Thu Jan 27 2011.
Info: Install Method: Parallel Process Restart
The install operation will continue asynchronously.
RP/0/RSP0/CPU0:rbx-g2-a9(admin)#
RP/0/RSP0/CPU0:rbx-g2-a9(admin)#Info: The changes made to software configurations will not be persistent across system reloads. Use the command '(admin) install commit' to make changes persistent.
Info: Please verify that the system is consistent following the software change using the following commands:
Info: show system verify
Info: install verify packages
Install operation 16 completed successfully at 05:54:40 UTC Thu Jan 27 2011.

ok


Comment by OVH - Thursday, 27 January 2011, 06:59AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install remove disk0:asr9k-upgrade-p-4.0.1 synchronous
Thu Jan 27 05:55:08.336 UTC
Install operation 17 '(admin) install remove disk0:asr9k-upgrade-p-4.0.1 synchronous' started by user 'octave' via CLI at 05:55:08 UTC Thu Jan 27 2011.
Info: This operation will remove the following packages:
Info: disk0:asr9k-doc-4.0.1
Info: disk0:asr9k-adv-video-4.0.1
Info: disk0:asr9k-sbc-4.0.1
Info: disk0:asr9k-k9sec-4.0.1
Info: disk0:asr9k-diags-4.0.1
Info: disk0:asr9k-mgbl-4.0.1
Info: disk0:asr9k-mcast-4.0.1
Info: disk0:asr9k-mpls-4.0.1
Info: disk0:asr9k-rout-4.0.1
Info: disk0:asr9k-fwdg-4.0.1
Info: disk0:asr9k-lc-4.0.1
Info: disk0:asr9k-admin-4.0.1
Info: disk0:asr9k-upgrade-p-4.0.1
Info: After this install remove the following install rollback point will no longer be reachable, as the required packages will not be present:
Info: 14
Proceed with removing these packages? [confirm]
Install operation 17 completed successfully at 05:58:48 UTC Thu Jan 27 2011.

et on recommence ... mais sans le fichier upgrade de sacré bugs


Comment by OVH - Thursday, 27 January 2011, 07:05AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install add source

il y en a pour 1 heure.

en attandant on repasse l'OSPF dans son etat normal


Comment by OVH - Thursday, 27 January 2011, 07:31AM

Warning: Skipped adding the following packages as they were already present:
Warning: disk0:asr9k-doc-p-4.0.1
Warning: disk0:asr9k-k9sec-p-4.0.1
Warning: disk0:asr9k-mcast-p-4.0.1
Warning: disk0:asr9k-mgbl-p-4.0.1
Warning: disk0:asr9k-mini-p-4.0.1
Warning: disk0:asr9k-mpls-p-4.0.1
Warning: Please check:
Warning: - the set of active packages using '(admin) show install active'.
Warning: - the set of inactive packages using '(admin) show install inactive'.
Info: The following packages are now available to be activated:
Info:
Info: disk0:asr9k-doc-p-4.0.1
Info: disk0:asr9k-k9sec-p-4.0.1
Info: disk0:asr9k-mcast-p-4.0.1
Info: disk0:asr9k-mgbl-p-4.0.1
Info: disk0:asr9k-mini-p-4.0.1
Info: disk0:asr9k-mpls-p-4.0.1
Info:
Info: The packages can be activated across the entire router.
Info:
Install operation 18 completed successfully at 06:30:23 UTC Thu Jan 27 2011.
RP/0/RSP0/CPU0:rbx-g2-a9(admin)#

c'est reparti pour un tour


Comment by OVH - Thursday, 27 January 2011, 07:33AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install commit
Thu Jan 27 06:33:09.629 UTC
Install operation 20 '(admin) install commit' started by user 'octave' via CLI at 06:33:09 UTC Thu Jan 27 2011.
Install operation 20 completed successfully at 06:33:12 UTC Thu Jan 27 2011.


Comment by OVH - Thursday, 27 January 2011, 07:35AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#upgrade hw-module fpd all location all
Thu Jan 27 06:34:32.360 UTC

FPD upgrade has ended.


Comment by OVH - Thursday, 27 January 2011, 07:36AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#install remove inactive synchronous
Thu Jan 27 06:36:05.163 UTC


Comment by OVH - Thursday, 27 January 2011, 07:38AM

Proceed with removing these packages? [confirm]
Install operation 21 completed successfully at 06:37:52 UTC Thu Jan 27 2011.



Comment by OVH - Thursday, 27 January 2011, 07:39AM

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#sh install summary
Thu Jan 27 06:38:20.967 UTC
Default Profile:
SDRs:
Owner
Active Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#sh install inactive summary
Thu Jan 27 06:38:49.196 UTC
There are no inactive packages on the router.

RP/0/RSP0/CPU0:rbx-g2-a9(admin)#sh install committed summary
Thu Jan 27 06:39:06.993 UTC
Default Profile:
SDRs:
Owner
Committed Packages:
disk0:asr9k-mini-p-4.0.1
disk0:asr9k-doc-p-4.0.1
disk0:asr9k-k9sec-p-4.0.1
disk0:asr9k-mpls-p-4.0.1
disk0:asr9k-mgbl-p-4.0.1
disk0:asr9k-mcast-p-4.0.1

ok