FS#5162 — rbx-g1-a9
Attached to Project— Reseau Internet et Baies
| Incident | |
| Tout le réseau | |
| CLOSED | |
![]() |
la carte 6 a redémarré suite à un défaut:
LC/0/6/CPU0:Feb 20 18:57:14 UTC: pfm_node_lc[227]: %PLATFORM-PFM-0-CARD_RESET_REQ : pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-SYSMGR-2-REBOOT : reboot required, process (pfm_node_lc) reason (pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1)
Date: Tuesday, 22 February 2011, 15:00PMLC/0/6/CPU0:Feb 20 18:57:14 UTC: pfm_node_lc[227]: %PLATFORM-PFM-0-CARD_RESET_REQ : pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-SYSMGR-2-REBOOT : reboot required, process (pfm_node_lc) reason (pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1)
Reason for closing: Done
RSS for all categories

RP/0/RSP1/CPU0:Feb 20 18:55:16 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Set|online_diag_rsp[229493]|System Punt/Fabric/data Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (8, 5)
LC/0/6/CPU0:Feb 20 18:57:05 UTC: pfm_node_lc[227]: %PLATFORM-DIAGS-0-LC_NP_LOOPBACK_FAILED : Set|online_diag_lc[139345]|Line card NPU loopback Test(0x2000 006)|NP loopback failure count crossed threshold, $s
LC/0/6/CPU0:Feb 20 18:57:05 UTC: pfm_node_lc[227]: prm_fast_reset_subset fast reset api succeeded for chan 5
LC/0/6/CPU0:Feb 20 18:57:05 UTC: pfm_node_lc[227]: NP loopback recovery action: Succeded (NP bitmask:0x20)
LC/0/6/CPU0:Feb 20 18:57:10 UTC: ETHER_CTRL[155]: %PLATFORM-ETHER_CTRL-3-IF_OPERATION_FAIL : sending MAC to PRM, port 1, error code File exists
RP/0/RSP1/CPU0:Feb 20 18:57:12 UTC: BM-DISTRIB[1142]: %L2-BM-6-ACTIVE : TenGigE0/6/0/1 is Active as part of Bundle-Ether26
LC/0/6/CPU0:Feb 20 18:57:14 UTC: pfm_node_lc[227]: %PLATFORM-NP-0-HW_DOUBLE_ECC_ERROR : Set|prm_server[139342]|Network Processor Unit(0x1007005)|NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1
LC/0/6/CPU0:Feb 20 18:57:14 UTC: pfm_node_lc[227]: %PLATFORM-PFM-0-CARD_RESET_REQ : pfm_dev_sm_perform_recovery_action, Card reset requested by: Process I D: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5 , memId=17, subMemId=0x1
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-SYSMGR-2-REBOOT : reboot required, process (pfm_node_lc) reason (pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Rea son: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1)
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-LIBSYSMGR-3-PARSE : parse_args: parse error: unmatched "
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-SYSMGR-3-ERROR : sysmgr_shutdown_cleanup_handler: shutdown script execution timed-out! Node will reset
LC/0/6/CPU0:8:35: sysmgr[87]: %OS-SYSMGR-7-DEBUG : sysmgr_shutdown_cleanup_handler: shutdown script execution timed-out! Node will reset
LC/0/6/CPU0:8:35: syslog_dev[85]: pfm_node_lc[227]: Request Graceful Reboot via Sysmgr: Reason: pfm_dev_sm_perform_recovery_action, Card reset requested b y: Process ID: 139342 (prm_server), Fault Sev: 0, Target node: 0/6/CPU0, CompId: 0x1f, Device Handle: 0x1007005, CondID: 1001, Fault Reason: NP DOUBLE ECC ERROR, NP=5, memId=17, subMemId=0x1
LC/0/6/CPU0:Feb 20 18:57:14 UTC: sysmgr[87]: %OS-SYSMGR-3-ERROR : sysmgr_shutdown_cleanup_handler: shutdown triggered by (pfm_node_lc) did not complete in 45 seconds, shutting down
RP/0/RSP0/CPU0:Feb 20 18:57:35 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-SRSP_STANDBY_EOBC_FAILED : Set|online_diag_rsp[229493]|SRSP standby EOBC Test(0x20 00001)|failure threshold is 3, slot(s) failed: 8
RP/0/RSP1/CPU0:Feb 20 18:57:36 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR-3-NODE_CPU_RESET : Node 0/6/CPU0 CPU reset detected.
RP/0/RSP1/CPU0:Feb 20 18:57:36 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR-6-NODE_STATE_CHANGE : 0/6/CPU0 A9K-8T-L state:BRINGDOWN
RP/0/RSP1/CPU0:Feb 20 18:57:36 UTC: invmgr[214]: %PLATFORM-INV-6-NODE_STATE_CHANGE : Node: 0/6/CPU0, state: BRINGDOWN
RP/0/RSP0/CPU0:Feb 20 18:57:38 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-SRSP_ACTIVE_EOBC_FAILED : Set|online_diag_rsp[229493]|SRSP active EOBC Test(0x2000 002)|failure threshold is 3, slot(s) failed: 8
RP/0/RSP0/CPU0:Feb 20 18:57:40 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-SRSP_STANDBY_EOBC_FAILED : Clear|online_diag_rsp[229493]|SRSP standby EOBC Test(0x 2000001)|failure threshold is 3, slot(s) failed: 8
RP/0/RSP1/CPU0:Feb 20 18:57:41 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR-6-NODE_STATE_CHANGE : 0/6/CPU0 A9K-8T-L state:ROMMON
RP/0/RSP0/CPU0:Feb 20 18:57:43 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-SRSP_ACTIVE_EOBC_FAILED : Clear|online_diag_rsp[229493]|SRSP active EOBC Test(0x20 00002)|failure threshold is 3, slot(s) failed: 8
RP/0/RSP0/CPU0:Feb 20 18:57:56 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Clear|online_diag_rsp[229493]|System Punt/Fabric/da ta Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (8, 5)
RP/0/RSP1/CPU0:Feb 20 18:58:04 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR_HAL-6-BOOT_REQ_RECEIVED : Boot Request from 0/6/CPU0, RomMon Version: 1.3
RP/0/RSP1/CPU0:3w3d:11h:24:13: shelfmgr[314]: %PLATFORM-MBIMGR-7-IMAGE_VALIDATED : Remote location 0/6/CPU0: : MBI tftp:/disk0/asr9k-os-mbi-4.0.1/lc/mbias r9k-lc.vm validated
RP/0/RSP1/CPU0:Feb 20 18:58:04 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR-6-NODE_STATE_CHANGE : 0/6/CPU0 A9K-8T-L state:MBI-BOOTING
RP/0/RSP1/CPU0:Feb 20 18:58:26 UTC: pfm_node_rp[282]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Clear|online_diag_rsp[229493]|System Punt/Fabric/data Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (8, 5)
RP/0/RSP1/CPU0:Feb 20 18:59:01 UTC: shelfmgr[314]: %PLATFORM-SHELFMGR-6-NODE_STATE_CHANGE : 0/6/CPU0 A9K-8T-L state:MBI-RUNNING
LC/0/6/CPU0:15: init[65540]: %OS-INIT-7-MBI_STARTED : total time 8.832 seconds
LC/0/6/CPU0:18: insthelper[60]: %INSTALL-INSTHELPER-7-PKG_DOWNLOAD : MBI running; starting software download
LC/0/6/CPU0:Feb 20 18:59:13 UTC: sysmgr[87]: %OS-SYSMGR-5-NOTICE : Card is COLD started
LC/0/6/CPU0:29: init[65540]: %OS-INIT-7-INSTALL_READY : total time 22.858 seconds
Nous allons remplacer la carte #6 du g1 par la carte #4 du g2 sur laquelle nous avons des ports non-utilisés ou sur lesquels nous avons peu de trafic.
Les cartes sont en place.