FS#5207 — p19-52

Attached to Project— Reseau Internet et Baies
Incident
Tout le réseau
CLOSED
100%
La carte #7 ne va pas bien. On va devoir la redemarrer.

Avant on va bouger un lien 10G sur une autre carte pour
assurer une meilleure redondance.
Date:  Monday, 07 March 2011, 02:42AM
Reason for closing:  Done
Comment by OVH - Sunday, 06 March 2011, 23:19PM

Mar 6 20:34:07: %TFIB-SP-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 40E40578 40E40904 40F1664C 40E18AD8 40E19078 40DFF760 40DFFB7C 40DFFE58 40E00AD8
Mar 6 20:34:20: %TFIB-DFC7-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:34:39: %TFIB-DFC9-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:34:43: %TFIB-DFC6-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:34:58: %TFIB-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 420DD078 420DD404 422D3E70 4064A764 4064B3FC 422D2230 407B392C 407B3DDC 407B454C 41049CDC 4016C59C
Mar 6 20:35:36: %TFIB-SP-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 40E40578 40E40904 40F1664C 40E18AD8 40E19078 40DFF760 40DFFB7C 40DFFE58 40E00AD8
Mar 6 20:35:48: %TFIB-DFC8-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:36:06: %TFIB-DFC7-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:36:16: %TFIB-DFC9-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:36:27: %TFIB-DFC6-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:36:34: %TFIB-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 420DD078 420DD404 422D3E70 4064A764 4064B3FC 422D2230 407B392C 407B3DDC 407B454C 41049CDC 4016C59C
Mar 6 20:37:04: %TFIB-SP-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 40E40578 40E40904 40F1664C 40E18AD8 40E19078 40DFF760 40DFFB7C 40DFFE58 40E00AD8
Mar 6 20:37:27: %TFIB-DFC8-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:37:49: %TFIB-DFC7-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:37:51: %TFIB-DFC9-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398
Mar 6 20:38:14: %TFIB-DFC6-7-SCANSABORTED: TFIB scan not completing. MAC string updated.
-Traceback= 20F6AE38 20F6B1C4 2103E87C 20F43398 20F43938 20F2A020 20F2A43C 20F2A718 20F2B398



le lien bougé.

la carte en reboot.


Comment by OVH - Monday, 07 March 2011, 00:00AM

amis du bug bonsoir ...

le port migré n'est pas entré dans le port channel (!?)
il est resté en dehors. du coup on a eu à gerer une
jolie boucle dans le reseau. le temps qu'on trouvé que
c'est lui à l'origine du probleme:

p19-52-6k#sh vlan id 3434
[...]
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
3434 active Te6/2, Po4, Po10
[...]
p19-52-6k#sh run inter ten 6/2
[...]
interface TenGigabitEthernet6/2
[...]
channel-group 10 mode active
[...]
p19-52-6k#sh inter po 10
[...]
Members in this channel: Te6/4 Te7/1 Te7/4
[...]
p19-52-6k#conf t
Enter configuration commands, one per line. End with CNTL/Z.
p19-52-6k(config)#inter ten 6/2
p19-52-6k(config-if)#shutdown
p19-52-6k(config-if)#no shutdown
p19-52-6k(config-if)#
p19-52-6k#sh inter po 10
[...]
Members in this channel: Te6/2 Te6/4 Te7/1 Te7/4
[...]
p19-52-6k#sh vlan id 3434
[...]
VLAN Name Status Ports
---- -------------------------------- --------- -------------------------------
3434 active Po4, Po10


Comment by OVH - Monday, 07 March 2011, 00:31AM

On va mettre à jour le routeur avec la nouvelle version
d'IOS. il se peut que ça fixe le probleme.


Comment by OVH - Monday, 07 March 2011, 02:42AM

http://travaux.ovh.net/?do=details&id=5175
la mise à jour d'IOS a fixé le bug software qui a fait
partir le routeur en crabe. le probleme est fixé.