N5/N56/N6 ISSU campain
Scheduled Maintenance Report for Network & Infrastructure
Completed
Description:

An upgrade campaign is launched on all Nexus 5000/5600/6000 of Baremetal aggregator switches.


Maintenance date:
16 August 2021, 20:00 - 23:59 (UTC Time)
ISSU: No Service Impact Expected.
gra1-40a/b-n56
rbx1-11a/b-n6

Maintenance date:
16 August 2021, 20:00 - 23:59 (UTC Time)
Relaod: Expected 1-2 mins of Interruption
sw.5.39.74.248/249-n5 (Subnets impacted:5.39.74.0/24, 5.39.75.0/24)

///////////////////////////

Maintenance date:
17 August 2021, 20:00 - 23:59 (UTC Time)
ISSU: No Service Impact Expected.
gra1-44a/b-n56
sw.176.31.230.248/249-n5

Maintenance date:
17 August 2021, 20:00 - 23:59 (UTC Time)
Relaod: Expected 1-2 mins of Interruption
sw.5.135.142.248/249-n5 (Subnets impacted: 5.135.142.0/24, 5.135.143.0/24)

///////////////////////////

Maintenance date:
18 August 2021, 20:00 - 23:59 (UTC Time)
ISSU: No Service Impact Expected.
gra1-46a/b-n56
sw.188.165.13.248/249-n5

Maintenance date:
18 August 2021, 20:00 - 23:59 (UTC Time)
Relaod: Expected 1-2 mins of Interruption
sw.178.33.232.248/249-n5 (Subnets impacted: 178.33.232.0/24, 178.33.233.0/24)






Update(s):

Date: 2021-08-19 04:27:11 UTC
migration done sw.178.33.232.248/249-n5

Date: 2021-08-19 02:11:20 UTC
we are upgrading sw.178.33.232.248/249-n5

Date: 2021-08-18 23:48:32 UTC
upgrade is completed successfully.

Date: 2021-08-18 19:25:58 UTC
we are starting upgrade of gra1-46a/b-n56 sw.188.165.13.248/249-n5 shortly.

Date: 2021-08-18 00:43:43 UTC
Maintenance on sw.5.135.142.248/249-n5 done

Date: 2021-08-17 23:32:19 UTC
upgrade of gra1-44a/b-n56 and sw.176.31.230.248/249-n5 are completed successfully.

Date: 2021-08-17 21:03:28 UTC
Reloading sw.5.135.142.248-n5

Date: 2021-08-17 20:57:51 UTC
Starting Isolation of sw.5.135.142.248/249-n5

Date: 2021-08-17 19:23:56 UTC
=============================================================
starting upgrade of gra1-44a/b-n56 and sw.176.31.230.248/249-n5 shortly

Date: 2021-08-17 00:40:56 UTC
we recovered the remaining of the IPs for vlan447. Only rbx1-11a/b-n6 was upgrade. gra1-40a/b-n56 is posponed.

Date: 2021-08-17 00:34:58 UTC
maintenance on sw.5.39.74.248/249-n5 done, we had some ip loss during this maintenance.
We apologize for the inconvenience caused.

Date: 2021-08-16 23:11:37 UTC
we succeed to recover most of IPs. It remained vlan 477

Date: 2021-08-16 22:17:11 UTC
we lost IPs on switch rbx1-11a/b-n6. We are investigating to recover them


Date: 2021-08-16 22:16:33 UTC
maintenance on sw.5.39.74.248/249-n5 still inprogress .

Date: 2021-08-16 19:58:27 UTC
Starting maintenance on sw.5.39.74.248/249-n5

Date: 2021-08-16 19:15:05 UTC
starting upgrade of gra1-40a/b-n56 and rbx1-11a/b-n6
Posted Jul 27, 2021 - 21:48 UTC