FS#52978 — N5/N56/N6 ISSU campain

Attached to Project— Network and racks
Maintenance
Entire OVH Network
CLOSED
100%
escription:
An upgrade campaign is launched on all Nexus 5000/5600/6000 of Baremetal aggregator switches.



Maintenance date: 07th September 2021, 20:00 - 23:59 (UTC Time) in Roubaix, FR datacenter
ISSU: No Service Impact Expected.
sw.178.33.234.248/249-n5
sw.37.187.68.248/249-n5

Maintenance date: 07th September 2021, 20:00 - 23:59 (UTC Time) in Roubaix, FR datacenter
Reload: Could have 2 to 5 minutes impact.
sw.5.135.135.248/249-n5 (Impacted subnet: 5.135.135.0/24)

Maintenance date: 07th September 2021, 07:00 - 11:00 (UTC Time) in Beauharnois, CA datacenter
Reload: Could have 2 to 5 minutes impact.
bhs6-12a/b-n56 (Impacted subnets: 142.44.142.0/24, 54.39.28.0/24)

//////////////////////////////////

Maintenance date: 08th September 2021, 20:00 - 23:59 (UTC Time) in Roubaix, FR datacenter
ISSU: No Service Impact Expected.
sw.5.39.66.248/249-n5

Maintenance date: 08th September 2021, 07:00 - 11:00 (UTC Time) in Beauharnois, CA datacenter
ISSU: No Service Impact Expected.
sw.142.4.218.248/249-n5

Maintenance date: 08th September 2021, 20:00 - 23:59 (UTC Time) in Graveline, FR datacenter
Reload: Could have 2 to 5 minutes impact.
gra1-47a/b-n56

/////////////////////////////

Maintenance date: 09th September 2021, 20:00 - 23:59 (UTC Time) in Roubaix, FR datacenter
ISSU: No Service Impact Expected.
sw.5.135.142.248/249-n5
sw.46.105.104.248/249-n5



Date:  Friday, 10 September 2021, 01:28AM
Reason for closing:  Done
Additional comments about closing:  succes
Comment by OVH - Tuesday, 07 September 2021, 21:05PM

I am starting the upgrade shortly


Comment by OVH - Wednesday, 08 September 2021, 02:12AM

maintenance on sw.5.135.135.248/249-n5 starting


Comment by OVH - Wednesday, 08 September 2021, 02:22AM

the upgrades of sw.178.33.234.248/249-n5 sw.37.187.68.248/249-n5 are completed.


Comment by OVH - Wednesday, 08 September 2021, 04:52AM

maintenance on sw.5.135.135.248/249-n5 is done


Comment by OVH - Wednesday, 08 September 2021, 21:28PM

we are starting upgrade of sw.5.39.66.248/249-n5 shortly.


Comment by OVH - Wednesday, 08 September 2021, 22:48PM

gra1-47a/b-n56 intervention is ongoing.
2 fex went down on B side (prmiary) when we reload A side (secondary)


Comment by OVH - Wednesday, 08 September 2021, 23:33PM

First step is over.


Comment by OVH - Thursday, 09 September 2021, 01:23AM

We will start the upgrade process.


Comment by OVH - Thursday, 09 September 2021, 01:52AM

upgrade of sw.5.39.66.248/249-n5 is completed


Comment by OVH - Thursday, 09 September 2021, 02:01AM

Upgrade done for gra1-47a/b-n56


Comment by OVH - Friday, 10 September 2021, 01:28AM

Upgrade done
sw.5.135.142.248/249-n5
sw.46.105.104.248/249-n5