FS#5469 — filerz383.perso / homez.383

Attached to Project— Hébergements web
Maintenance
P19 / cluster010 (60gp)
CLOSED
100%
Un module de mémoire s'est mis en défaut sur le serveur et a été mis hors service automatiquement, nous allons le remplacer cette nuit.

Une brève coupure pourra être observée lors du remplacement.

Les sites hébergés sur /homez.383 sont concernés par cette maintenance.

--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
--------------- ------------------------------------ -------------- ---------
May 24 12:17:25 4766b669-91b1-4757-f805-80efa8b254be INTEL-8001-94 Major

Host : filerz383
Platform : System Product Name Chassis_id : System Serial Number

Fault class : fault.memory.intel.dimm_ce
Affects : hc://:product-id=System-Product-Name:chassis-id=System:server-id=filerz383:serial=1801010811012216a5:revision=D1/motherboard=0/memory-controller=0/dram-channel=0/dimm=0/rank=0
faulted but still in service
FRU : "M1" (hc://:product-id=System-Product-Name:chassis-id=System:server-id=filerz383:serial=1801010811012216a5:revision=D1/motherboard=0/memory-controller=0/dram-channel=0/dimm=0)
faulty

Description : The number of correctable errors associated with this memory
module has exceeded acceptable levels. Refer to
http://sun.com/msg/INTEL-8001-94 for more information.

Response : Pages of memory associated with this memory module may have been
removed from service, up to a limit which has now been reached.

Impact : Total system memory capacity has been reduced (where supported).

Action : Schedule a repair procedure to replace the affected memory
module. Use 'fmadm faulty' to identify the memory module.

Date:  Wednesday, 25 May 2011, 02:41AM
Reason for closing:  Done
Comment by OVH - Wednesday, 25 May 2011, 02:25AM

Nous allons démarrer l'intervention.


Comment by OVH - Wednesday, 25 May 2011, 02:41AM

Terminée.