provisionning de nouveaux clients
Scheduled Maintenance Report for Hosted Private Cloud
Completed
Nous allons provisionner de nouveaux reseaux.

Update(s):

Date: 2011-07-28 19:58:37 UTC
pcc-23-n5(config-if)# wr
[########################################] 100%
pcc-23-n5(config-if)# inter e100/1/1-32
pcc-23-n5(config-if-range)# switchport trunk allowed vlan remove 3000-3001,3003-3096
2011 Jul 28 21:58:22 pcc-23-n5 %SYSMGR-2-SERVICE_CRASHED: Service \"provision\" (PID 4574) hasn't caught signal 11 (core will be saved).

toujours pas.

Date: 2011-07-28 19:58:08 UTC
pcc-23-n5(config)# inter e100/1/1
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/2
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/3
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/4
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/5
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/6
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/7
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/8
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/9
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/10
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/11
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/12
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/13
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/14
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/15
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/16
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/17
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/18
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/19
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/20
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/21
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/22
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/23
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/24
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/25
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/26
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/27
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/28
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/29
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/30
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/31
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)# inter e100/1/32
pcc-23-n5(config-if)# switchport trunk allowed vlan remove 3000-3001,3003-3096
pcc-23-n5(config-if)#

et ça passe. donc un jolie bug de CLI.

Date: 2011-07-28 19:55:05 UTC
une configuration non homogene de
switchport trunk allowed vlan xxx
fait planter le N5.

pcc-23-n5(config-if)# sh run inter e100/1/1-32 | i \"switchport trunk allowed vlan\"
[...]

Date: 2011-07-28 19:52:39 UTC
pcc-23-n5(config-if)# inter e100/1/1-32
pcc-23-n5(config-if-range)# switchport trunk allowed vlan remove 3000-3001,3003-3096
2011 Jul 28 21:33:27 pcc-23-n5 %SYSMGR-2-SERVICE_CRASHED: Service \"provision\" (PID 4542) hasn't caught signal 11 (core will be saved).

sur 2 ça ne passe pas. sur les 26 autres sans probleme.

Date: 2011-07-28 19:45:18 UTC
version 5.0(3)N1(1b)
version 5.0(3)N1(1c)

bon il faut mettre tout ça à jour.

Date: 2011-07-28 19:41:00 UTC
pcc-23 est up.

pcc-23-n5(config-if-range)# switchport trunk allowed vlan remove 3000-3001,3003-3096
2011 Jul 28 21:40:23 pcc-23-n5 %SYSMGR-2-SERVICE_CRASHED: Service \"provision\" (PID 4574) hasn't caught signal 11 (core will be saved).

bon ça pue un bug software.

Date: 2011-07-28 19:36:11 UTC
pcc-17b-n5(config-if-range)# switchport trunk allowed vlan remove 3000-3001,3003-3096
2011 Jul 28 21:34:01 pcc-17b-n5 %SYSMGR-2-SERVICE_CRASHED: Service \"provision\" (PID 4321) hasn't caught signal 11 (core will be saved).


Date: 2011-07-28 19:35:39 UTC
pcc-23-n5(config-if-range)# switchport trunk allowed vlan remove 3000-3001,3003-3096
2011 Jul 28 21:33:27 pcc-23-n5 %SYSMGR-2-SERVICE_CRASHED: Service \"provision\" (PID 4542) hasn't caught signal 11 (core will be saved).

aie
Posted Jul 28, 2011 - 18:50 UTC