OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
rbx-97-n7
Scheduled Maintenance Report for Network & Infrastructure
Completed
Nous allons mettre à jour le switch. Il gere iSCSI
de RPS, backup et les NAS

Update(s):

Date: 2011-08-18 10:29:58 UTC
panne constatée lors de la mise à jour:

entre les routeurs à Roubaix
3069 packets transmitted, 3069 received, 0% packet loss

vers les NAS, iSCSI et backup
3195 packets transmitted, 3195 received, 0% packet loss

c'est là qu'on aime Cisco: quand ils font du bon boulot
en proposant le matos qui fait ce qu'il est annoncé.

Date: 2011-08-18 10:28:03 UTC
rbx-97-n7# sh install all status
Install has been successful.


Date: 2011-08-18 10:23:35 UTC

2011 Aug 18 12:02:40 rbx-97-n7 %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 9) is now UP
2011 Aug 18 12:02:42 rbx-97-n7 %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting...
2011 Aug 18 12:05:03 rbx-97-n7 %IDEHSD-STANDBY-2-MOUNT: logflash: online
2011 Aug 18 12:05:29 rbx-97-n7 %MODULE-5-STANDBY_SUP_OK: Supervisor 9 is standby
2011 Aug 18 12:05:29 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 1 started
2011 Aug 18 12:05:29 rbx-97-n7 %SYSMGR-SLOT1-5-LC_UPGRADE_START: Starting linecard upgrade
2011 Aug 18 12:06:19 rbx-97-n7 %SYSMGR-SLOT1-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2011 Aug 18 12:07:03 rbx-97-n7 %SYSMGR-SLOT1-4-READCONF_STARTED: Configuration update started (PID 1901).
2011 Aug 18 12:07:04 rbx-97-n7 %SYSMGR-SLOT1-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1902).
2011 Aug 18 12:07:10 rbx-97-n7 %SYSMGR-SLOT1-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2011 Aug 18 12:07:28 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 1 ended
2011 Aug 18 12:07:28 rbx-97-n7 %MODULE-5-MOD_OK: Module 1 is online (serial: )
2011 Aug 18 12:07:28 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_ONLINE/OK
2011 Aug 18 12:07:27 rbx-97-n7 %SYSMGR-SLOT1-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2011 Aug 18 12:07:54 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 2 started
2011 Aug 18 12:07:53 rbx-97-n7 %SYSMGR-SLOT2-5-LC_UPGRADE_START: Starting linecard upgrade
2011 Aug 18 12:08:49 rbx-97-n7 %SYSMGR-SLOT2-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2011 Aug 18 12:09:33 rbx-97-n7 %SYSMGR-SLOT2-4-READCONF_STARTED: Configuration update started (PID 1901).
2011 Aug 18 12:09:34 rbx-97-n7 %SYSMGR-SLOT2-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1902).
2011 Aug 18 12:09:41 rbx-97-n7 %SYSMGR-SLOT2-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2011 Aug 18 12:09:59 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 2 ended
2011 Aug 18 12:09:59 rbx-97-n7 %MODULE-5-MOD_OK: Module 2 is online (serial: )
2011 Aug 18 12:09:59 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 2 current-status is MOD_STATUS_ONLINE/OK
2011 Aug 18 12:09:59 rbx-97-n7 %SYSMGR-SLOT2-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2011 Aug 18 12:10:11 rbx-97-n7 %BIOS_DAEMON-SLOT1-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2011 Aug 18 12:10:25 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 3 started
2011 Aug 18 12:10:25 rbx-97-n7 %SYSMGR-SLOT3-5-LC_UPGRADE_START: Starting linecard upgrade
2011 Aug 18 12:11:29 rbx-97-n7 %SYSMGR-SLOT3-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2011 Aug 18 12:12:27 rbx-97-n7 %SYSMGR-SLOT3-4-READCONF_STARTED: Configuration update started (PID 1903).
2011 Aug 18 12:12:28 rbx-97-n7 %SYSMGR-SLOT3-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1904).
2011 Aug 18 12:12:35 rbx-97-n7 %SYSMGR-SLOT3-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2011 Aug 18 12:12:42 rbx-97-n7 %BIOS_DAEMON-SLOT2-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2011 Aug 18 12:13:00 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 3 ended
2011 Aug 18 12:13:00 rbx-97-n7 %MODULE-5-MOD_OK: Module 3 is online (serial: )
2011 Aug 18 12:13:00 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 3 current-status is MOD_STATUS_ONLINE/OK
2011 Aug 18 12:12:59 rbx-97-n7 %SYSMGR-SLOT3-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2011 Aug 18 12:13:26 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 4 started
2011 Aug 18 12:13:26 rbx-97-n7 %SYSMGR-SLOT4-5-LC_UPGRADE_START: Starting linecard upgrade
2011 Aug 18 12:13:31 rbx-97-n7 %SYSMGR-SLOT4-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2011 Aug 18 12:14:02 rbx-97-n7 %SYSMGR-SLOT4-4-READCONF_STARTED: Configuration update started (PID 1866).
2011 Aug 18 12:14:03 rbx-97-n7 %SYSMGR-SLOT4-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1867).
2011 Aug 18 12:14:05 rbx-97-n7 %SYSMGR-SLOT4-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2011 Aug 18 12:15:35 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 4 ended
2011 Aug 18 12:15:35 rbx-97-n7 %MODULE-5-MOD_OK: Module 4 is online (serial: )
2011 Aug 18 12:15:35 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 4 current-status is MOD_STATUS_ONLINE/OK
2011 Aug 18 12:15:35 rbx-97-n7 %SYSMGR-SLOT4-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2011 Aug 18 12:15:36 rbx-97-n7 %BIOS_DAEMON-SLOT3-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2011 Aug 18 12:16:01 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module 5 started
2011 Aug 18 12:16:01 rbx-97-n7 %SYSMGR-SLOT5-5-LC_UPGRADE_START: Starting linecard upgrade
2011 Aug 18 12:16:07 rbx-97-n7 %SYSMGR-SLOT5-5-LC_UPGRADE_REBOOT: Rebooting linecard as a part of upgrade
2011 Aug 18 12:16:39 rbx-97-n7 %SYSMGR-SLOT5-4-READCONF_STARTED: Configuration update started (PID 1866).
2011 Aug 18 12:16:39 rbx-97-n7 %SYSMGR-SLOT5-5-RUNTIME_DB_RESTORE_STARTED: Runtime database controller started (PID 1867).
2011 Aug 18 12:16:41 rbx-97-n7 %SYSMGR-SLOT5-5-RUNTIME_DB_RESTORE_SUCCESS: Runtime database successfully restored.
2011 Aug 18 12:17:06 rbx-97-n7 %BIOS_DAEMON-SLOT4-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2011 Aug 18 12:18:12 rbx-97-n7 %MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module 5 ended
2011 Aug 18 12:18:12 rbx-97-n7 %MODULE-5-MOD_OK: Module 5 is online (serial: )
2011 Aug 18 12:18:12 rbx-97-n7 %PLATFORM-5-MOD_STATUS: Module 5 current-status is MOD_STATUS_ONLINE/OK
2011 Aug 18 12:18:11 rbx-97-n7 %SYSMGR-SLOT5-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2011 Aug 18 12:19:42 rbx-97-n7 %BIOS_DAEMON-SLOT5-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash


Date: 2011-08-18 10:02:59 UTC
Par contre le BGP vers les RR se coupe
2011 Aug 18 11:56:43 CEST: %BGP-5-ADJCHANGE: bgp-16276 [7038] (default) neighbor xx.xx.xx.xx UP
2011 Aug 18 11:56:44 CEST: %BGP-5-ADJCHANGE: bgp-16276 [7038] (default) neighbor yy.yy.yy.yy UP

Date: 2011-08-18 10:01:35 UTC
2011 Aug 18 11:56:24 CEST: Aug 18 11:56:23 %KERN-2-SYSTEM_MSG: Switchover started by redundancy driver - kernel
2011 Aug 18 11:56:24 CEST: %SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active (pre-start phase).
2011 Aug 18 11:56:24 CEST: %SYSMGR-2-HASWITCHOVER_START: Supervisor 10 is becoming active.
2011 Aug 18 11:56:25 CEST: Aug 18 11:56:24 %KERN-2-SYSTEM_MSG: do_mts_standby_sync_thread(): Standby sync thread shutdown - kernel
2011 Aug 18 11:56:25 CEST: %VDC_MGR-5-VDC_STATE_CHANGE: vdc 1 state changed to active
2011 Aug 18 11:56:25 CEST: last message repeated 1 time
2011 Aug 18 11:56:25 CEST: %ASCII-CFG-6-INFORMATION: Reading ACFG Runtime information
2011 Aug 18 11:56:25 CEST: %SYSMGR-2-SWITCHOVER_OVER: Switchover completed.
2011 Aug 18 11:56:25 CEST: %VDC_MGR-5-VDC_MODULETYPE: vdc_mgr: Module type changed to m1 f1 m1xl
2011 Aug 18 11:56:26 CEST: last message repeated 1 time

rbx-97-n7# sh module
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
1 48 1000 Mbps Optical Ethernet XL Modul N7K-M148GS-11L ok
2 8 10 Gbps Ethernet XL Module N7K-M108X2-12L ok
3 32 10 Gbps Ethernet Module N7K-M132XP-12 ok
4 32 1/10 Gbps Ethernet Module N7K-F132XP-15 ok
5 32 1/10 Gbps Ethernet Module N7K-F132XP-15 ok
9 0 Supervisor module-1X powered-up
10 0 Supervisor module-1X N7K-SUP1 active *

Mod Sw Hw
--- -------------- ------
1 5.1(3) 1.0
2 5.1(3) 1.0
3 5.1(3) 1.7
4 5.1(3) 1.0
5 5.1(3) 1.0
10 5.2(1) 1.6



Date: 2011-08-18 09:51:33 UTC
Do you want to continue with the installation (y/n)? [n] y

Install is in progress, please wait.

Performing runtime checks.
[####################] 100% -- SUCCESS

Syncing image bootflash:/n7000-s1-kickstart.5.2.1.bin to standby.
[####################] 100% -- SUCCESS

Syncing image bootflash:/n7000-s1-dk9.5.2.1.bin to standby.
[####################] 100% -- SUCCESS

Setting boot variables.
[####################] 100% -- SUCCESS

Performing configuration copy.
[####################] 100% -- SUCCESS

Module 1: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 2: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 3: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 4: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 5: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 9: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS

Module 10: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS
2011 Aug 18 11:47:36 rbx-97-n7 %PLATFORM-2-MOD_REMOVE: Module 10 removed (Serial number )
2011 Aug 18 11:53:24 CEST: %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 10) is now UP
2011 Aug 18 11:53:38 CEST: %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting...
2011 Aug 18 11:54:54 CEST: %MODULE-5-STANDBY_SUP_OK: Supervisor 10 is standby
Module 10: Waiting for module online.
-- SUCCESS
2011 Aug 18 11:56:10 CEST: %IDEHSD-STANDBY-2-MOUNT: logflash: online
Notifying services about the switchover.
[####################] 100% -- SUCCESS


\"Switching over onto standby\".
Connection closed by foreign host.



Date: 2011-08-18 09:38:41 UTC
Compatibility check is done:
Module bootable Impact Install-type Reason
------ -------- -------------- ------------ ------
1 yes non-disruptive rolling
2 yes non-disruptive rolling
3 yes non-disruptive rolling
4 yes non-disruptive rolling
5 yes non-disruptive rolling
9 yes non-disruptive reset
10 yes non-disruptive reset


Date: 2011-08-18 09:34:40 UTC
rbx-97-n7# install all kickstart bootflash:n7000-s1-kickstart.5.2.1.bin system bootflash:n7000-s1-dk9.5.2.1.bin



Date: 2011-08-18 09:33:35 UTC
rbx-97-n7# sh redundancy status
Redundancy mode
---------------
administrative: HA
operational: HA

This supervisor (sup-9)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with HA standby

Other supervisor (sup-10)
------------------------
Redundancy state: Standby

Supervisor state: HA standby
Internal state: HA standby

System start time: Wed Jul 21 00:19:40 2010

System uptime: 393 days, 16 hours, 55 minutes, 32 seconds
Kernel uptime: 134 days, 20 hours, 7 minutes, 52 seconds
Active supervisor uptime: 134 days, 19 hours, 55 minutes, 30 seconds

rbx-97-n7# sh system redundancy ha status
VDC No This supervisor Other supervisor
------ --------------- ---------------

vdc 1 Active with HA standby HA standby
vdc 2 N/A N/A
vdc 3 Active with HA standby HA standby
vdc 4 N/A N/A
Posted Aug 18, 2011 - 09:30 UTC