pdc1-1
Incident Report for Network & Infrastructure
Resolved
Nous avons un problème sur ce routeur. Le trafic est impacté. Nous investiguons.

Update(s):

Date: 2011-09-12 09:43:43 UTC
client à contacter

interface Vlan1219
description IOCEAN


Date: 2011-09-12 09:43:18 UTC
trouvé

pdc1-1-m2#sh proc cpu
CPU utilization for five seconds: 98%/48%; one minute: 98%; five minutes: 97%
pdc1-1-m2#conf t
Enter configuration commands, one per line. End with CNTL/Z.
pdc1-1-m2(config)#inter vlan 1219
pdc1-1-m2(config-if)#shutdown
pdc1-1-m2(config-if)#end
pdc1-1-m2#sh proc cpu | i CPU
CPU utilization for five seconds: 38%/21%; one minute: 93%; five minutes: 96%
79 0 2 0 0.00% 0.00% 0.00% 0 SLB Main CPU pro
pdc1-1-m2#sh proc cpu | i CPU
CPU utilization for five seconds: 38%/21%; one minute: 93%; five minutes: 96%
79 0 2 0 0.00% 0.00% 0.00% 0 SLB Main CPU pro
pdc1-1-m2#sh proc cpu | i CPU
CPU utilization for five seconds: 38%/21%; one minute: 93%; five minutes: 96%
79 0 2 0 0.00% 0.00% 0.00% 0 SLB Main CPU pro
pdc1-1-m2#sh proc cpu | i CPU
CPU utilization for five seconds: 13%/5%; one minute: 87%; five minutes: 95%
79 0 2 0 0.00% 0.00% 0.00% 0 SLB Main CPU pro
pdc1-1-m2#sh proc cpu | i CPU
CPU utilization for five seconds: 9%/4%; one minute: 81%; five minutes: 94%


Date: 2011-09-12 09:43:01 UTC
Nous avons identifié et isolé le vlan posant pb. Le trafic est rétabli.

Date: 2011-09-12 09:38:32 UTC
il y a un trafic arp anormal:
9 13361008 39282357 340 35.12% 33.76% 37.00% 0 ARP Input
Posted Sep 12, 2011 - 09:37 UTC