NYIIX
Incident Report for Network & Infrastructure
Resolved
On se prend une attaque sur le vlan de NYIIX.
C'est probablement un probleme general chez
NYYIX. On a coupé le port.

interface Te2/2, routine mistral_process_rx_packet_inlin, timestamp 01:33:29.850
dbus info: src_vlan 0x400(1024), src_indx 0x41(65), len 0xDC(220)
bpdu 1, index_dir 1, flood 0, dont_lrn 0, dest_indx 0x380(896)
3F020010 04002800 00410000 DC020000 FE000014 00000000 00000000 03800000
mistral hdr: req_token 0x0(0), src_index 0x41(65), rx_offset 0x76(118)
requeue 0, obl_pkt 0, vlan 0x400(1024)
destmac 01.80.C2.00.00.0E, srcmac 2C.6B.F5.31.76.B0, protocol 88CC
layer 3 data: 0207042C 6BF53176 80040407 36313306 0200780A 0D616363
312D746C 68312D6A 666B0C59 4A756E69 70657220 4E657477
6F726B73 2C20496E 0000FFFF 00000041 00000380 1800
Posted Mar 09, 2012 - 00:56 UTC