rbx-97
Scheduled Maintenance Report for Network & Infrastructure
Completed
Nous constatons un probleme de table de routage sur une carte de rbx-97-n7.

2012 May 18 16:38:20 rbx-97-n7 %IPFIB-SLOT3-2-FIB_TCAM_RESOURCE_EXHAUSTION: FIB TCAM exhausted for IPV4 unicast
2012 May 18 16:38:20 rbx-97-n7 %IPFIB-SLOT3-4-FIB_TCAM_AF_INSERT_FAIL: FIB TCAM prefix insertion fail for IPV4 unicast
2012 May 18 16:38:36 rbx-97-n7 %IPFIB-SLOT3-2-FIB_TCAM_RESOURCE_EXHAUSTION: FIB TCAM exhausted for IPV4 unicast
2012 May 18 16:38:36 rbx-97-n7 %IPFIB-SLOT3-4-FIB_TCAM_AF_INSERT_FAIL: FIB TCAM prefix insertion fail for IPV4 unicast
2012 May 18 16:38:53 rbx-97-n7 %IPFIB-SLOT3-2-FIB_TCAM_RESOURCE_EXHAUSTION: FIB TCAM exhausted for IPV4 unicast
2012 May 18 16:38:53 rbx-97-n7 %IPFIB-SLOT3-4-FIB_TCAM_AF_INSERT_FAIL: FIB TCAM prefix insertion fail for IPV4 unicast
rbx-97-n7#

En effet cette carte est en configuration \"light\" et ne possede pas assez de ressource pour le routage.

rbx-97-n7# sh mod
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------

3 32 10 Gbps Ethernet Module N7K-M132XP-12 ok

Une coupure de 5 a 10 secondes est a prévoir sur certain service. Voici les services associés :
- RPS (iSCSI et NFS),
- NAS-HA.

Nous débuterons la maintenance mardi 22 mai a 1:00 (CEST).

Update(s):

Date: 2012-05-21 23:52:36 UTC
Fait.

Il y a eu une coupure de service d'environ 5 min. Nous vérifions l'infrastructure.

Date: 2012-05-21 23:34:21 UTC
Effectué.

Nous passons a l'infrastructure RPS.

Date: 2012-05-21 23:21:54 UTC
Nous commencons par basculer l'infrastructure NAS-HA.
Posted May 18, 2012 - 14:54 UTC