OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
nyc-1-6k
Incident Report for Network & Infrastructure
Resolved
la carte 3 a laché.

Jun 14 09:14:23 GMT: %EARL-DFC3-2-SWITCH_BUS_IDLE: Switching bus is idle for 5 seconds. The card grant is 0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x46] JA_DR_RI_0_STA_FCO = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x85] JA_DR_RI_1_STA_FCO = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x28A] JA_FI_FT_RCV_RATE_SEL = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x289] JA_FI_FT_XMIT_SHAPE = 0xFFF
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4CB] JA_AG_PM_RAM_FULLNESS_0 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4CC] JA_AG_PM_RAM_FULLNESS_1 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4CD] JA_AG_PM_RAM_FULLNESS_2 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4CE] JA_AG_PM_RAM_FULLNESS_3 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4F1] JA_AG_RM_RAM_FULLNESS_0 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4F2] JA_AG_RM_RAM_FULLNESS_1 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4F3] JA_AG_RM_RAM_FULLNESS_2 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x4F4] JA_AG_RM_RAM_FULLNESS_3 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x5F6] JA_TM_HI_FULLNESS = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [0:0x5F7] JA_TM_LO_FULLNESS = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x46] JA_DR_RI_0_STA_FCO = 0x3
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x85] JA_DR_RI_1_STA_FCO = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x28A] JA_FI_FT_RCV_RATE_SEL = 0xC
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x289] JA_FI_FT_XMIT_SHAPE = 0xFFF
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4CB] JA_AG_PM_RAM_FULLNESS_0 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4CC] JA_AG_PM_RAM_FULLNESS_1 = 0x46
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4CD] JA_AG_PM_RAM_FULLNESS_2 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4CE] JA_AG_PM_RAM_FULLNESS_3 = 0x101
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4F1] JA_AG_RM_RAM_FULLNESS_0 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4F2] JA_AG_RM_RAM_FULLNESS_1 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4F3] JA_AG_RM_RAM_FULLNESS_2 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x4F4] JA_AG_RM_RAM_FULLNESS_3 = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x5F6] JA_TM_HI_FULLNESS = 0x0
Jun 14 09:14:23 GMT: %PF_ASIC-DFC3-3-ASIC_DUMP: [1:0x5F7] JA_TM_LO_FULLNESS = 0x0
Posted Jun 14, 2012 - 08:18 UTC