rbx-g2-a9
Incident Report for Network & Infrastructure
Resolved
Une carte du routeur backbone a re-démarré.

Aug 13 08:13:10 rbx-g2-a9.fr.eu 1080034: LC/0/2/CPU0:Aug 13 06:12:48 UTC: prm_server_ty[299]: prm_ser_check: Unable to repair Parity error on NP 0, block 0x29 (TM_SC_L234), offset 50, memid 377, name CLASS_SHAPING/CLASS_IQD_SHAPING, addr 0x00000321, bit 2147483648, ext info 0xffffffff 0xffffffff 0xffffffff 0xffffffff, action 0 (Fix)
Aug 13 08:13:10 rbx-g2-a9.fr.eu 1080035: LC/0/2/CPU0:Aug 13 06:12:48 UTC: pfm_node_lc[287]: %PLATFORM-NP-0-NON_RECOVERABLE_SOFT_ERROR : Set|prm_server_ty[172112]|Network Processor Unit(0x1008000)| A non-recoverable soft error has been detected on NP0. The linecard will be rebooted.
Aug 13 08:13:10 rbx-g2-a9.fr.eu 1080036: LC/0/2/CPU0:Aug 13 06:12:48 UTC: pfm_node_lc[287]: %PLATFORM-PFM-0-CARD_RESET_REQ : pfm_dev_sm_perform_recovery_action, Card reset requested by: Process ID: 172112 (prm_server_ty), Fault Sev: 0, Target node: 0/2/CPU0, CompId: 0x1f, Device Handle: 0x1008000, CondID: 1034, Fault Reason: A non-recoverable soft error has been detected on NP0. The linecard will be rebooted.
Aug 13 08:13:10 rbx-g2-a9.fr.eu 1080038: LC/0/2/CPU0:Aug 13 06:12:48 UTC: obflmgr[72]: %OS-OBFLMGR-4-FILE_ERROR : file:bootflash:/errmsg_cont(fp:5002ff6c, fd:18) lock failing. 0 retry so far. Error(1160546825): 'obflinfra' detected the 'warning' condition 'Posix error msg received from syscall': Bad file descriptor

Nous investiguons avec le constructeur.

Update(s):

Date: 2012-08-13 13:29:44 UTC
Il s'agit d'une erreur mémoire. Nous monitorons, si elle redémarre à nouveau, nous la changerons.
Posted Aug 13, 2012 - 13:19 UTC