OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
rbx-97-n7
Incident Report for Network & Infrastructure
Resolved
On a un probleme sur le rbx-97-n7



Update(s):

Date: 2012-10-09 19:59:28 UTC
Le routeur va mieux.

Date: 2012-10-09 19:38:12 UTC
On fait un switchover de la sup pour revenir à
la sup 1.

Date: 2012-10-09 19:21:14 UTC
Suite au reboot de 2 N5, le routeur a dû se
prendre un flood de requetes et il a crashé.
La carte sup slave a repris le trafic.

Date: 2012-10-09 19:16:33 UTC
2012 Oct 9 21:03:27 rbx-97-n7 %PLATFORM-2-PFM_MODULE_RESET: Manual restart of Module 9 from Command Line Interface
2012 Oct 9 21:10:00 rbx-97-n7 last message repeated 1 time
2012 Oct 9 21:10:00 rbx-97-n7 %CMPPROXY-STANDBY-2-LOG_CMP_UP: Connectivity Management processor(on module 9) is now UP
2012 Oct 9 21:10:11 rbx-97-n7 %BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting...
2012 Oct 9 21:12:06 rbx-97-n7 %IDEHSD-STANDBY-2-MOUNT: logflash: online
2012 Oct 9 21:13:35 rbx-97-n7 %MODULE-5-STANDBY_SUP_OK: Supervisor 9 is standby


Date: 2012-10-09 19:01:50 UTC
9 0 Supervisor module-1X powered-up

rbx-97-n7(config)# no poweroff module 9

9 0 Supervisor module-1X N7K-SUP1 removed

ah .. ça avance là.

Date: 2012-10-09 18:58:47 UTC
rbx-97-n7# reload cmp module 9
This command will reload the CMP on the supervisor in slot 9. Continue (y/n)? [no] y
ERROR: Cannot reload module 9. The module is either offline or not inserted



Date: 2012-10-09 18:48:19 UTC
rbx-97-n7# reload module 9
This command will reboot standby supervisor module. (y/n)? [n] y
about to reset standby sup


Date: 2012-10-09 18:45:29 UTC
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042433] mts_is_q_space_available_new():1533:Total mtsbuf size 30199027 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042454] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=308067(30199009), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042461] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042487] mts_print_msg_opcode_in_queue: opcode 19 - 2 messages - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042490] mts_print_msg_opcode_in_queue: opcode 21553 - 98 messages - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042512] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:35:05 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042613] node=4 sap=221 rq=308067(30199009) lq=0(0) pq=1(98) nq=0(0) sq=0(0) buf_in_transit=2029973, bytes_in_transit=110033187 - kernel
2012 Oct 9 20:35:06 rbx-97-n7 Oct 9 20:35:04 %KERN-2-SYSTEM_MSG: [4044238.042683] node=4 sap=337 rq=473(95546) lq=0(0) pq=0(0) nq=29(5858) sq=0(0) buf_in_transit=0, bytes_in_transit=0 - kernel
2012 Oct 9 20:35:14 rbx-97-n7 Oct 9 20:35:13 %KERN-2-SYSTEM_MSG: [4044247.674526] [0/221:l2fm] Need wild send recovery - kernel
2012 Oct 9 20:35:26 rbx-97-n7 Oct 9 20:35:25 %KERN-2-SYSTEM_MSG: [4044259.521510] mts_acquire_q_space() failing - no space in sap 221, uuid 410 send_opc 21568, pid 5941, proc_name l2fm - kernel
2012 Oct 9 20:35:35 rbx-97-n7 Oct 9 20:35:35 %KERN-2-SYSTEM_MSG: [4044268.735718] mts_is_q_space_available_new():1533:Total mtsbuf size 29388910 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:35:35 rbx-97-n7 Oct 9 20:35:35 %KERN-2-SYSTEM_MSG: [4044268.735741] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=299802(29388812), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:35:35 rbx-97-n7 Oct 9 20:35:35 %KERN-2-SYSTEM_MSG: [4044268.735748] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:35:35 rbx-97-n7 Oct 9 20:35:35 %KERN-2-SYSTEM_MSG: [4044268.735776] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:35:35 rbx-97-n7 Oct 9 20:35:35 %KERN-2-SYSTEM_MSG: [4044268.736396] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:36:04 rbx-97-n7 Oct 9 20:36:04 %KERN-2-SYSTEM_MSG: [4044298.047146] [sap 221][pid 5941][comm:l2fm] QFULL drop notify posted - kernel
2012 Oct 9 20:36:05 rbx-97-n7 Oct 9 20:36:05 %KERN-2-SYSTEM_MSG: [4044298.761498] mts_is_q_space_available_new():1533:Total mtsbuf size 26688941 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:36:05 rbx-97-n7 Oct 9 20:36:05 %KERN-2-SYSTEM_MSG: [4044298.761519] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=272273(26688843), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:36:05 rbx-97-n7 Oct 9 20:36:05 %KERN-2-SYSTEM_MSG: [4044298.761526] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:36:05 rbx-97-n7 Oct 9 20:36:05 %KERN-2-SYSTEM_MSG: [4044298.761558] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:36:05 rbx-97-n7 Oct 9 20:36:05 %KERN-2-SYSTEM_MSG: [4044298.761641] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:36:31 rbx-97-n7 Oct 9 20:36:30 %KERN-2-SYSTEM_MSG: [4044324.661597] mts_acquire_q_space() failing - no space in sap 221, uuid 410 send_opc 21568, pid 5941, proc_name l2fm - kernel
2012 Oct 9 20:36:32 rbx-97-n7 %ADJMGR-3-MTS_SEND: adjmgr [5086] Failed to send Mac registration to L2FM queue: Device or resource busy
2012 Oct 9 20:36:37 rbx-97-n7 Oct 9 20:36:37 %KERN-2-SYSTEM_MSG: [4044331.427556] mts_is_q_space_available_new():1533:Total mtsbuf size 26020772 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:36:37 rbx-97-n7 Oct 9 20:36:37 %KERN-2-SYSTEM_MSG: [4044331.427591] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=265401(26020674), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:36:37 rbx-97-n7 Oct 9 20:36:37 %KERN-2-SYSTEM_MSG: [4044331.427597] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:36:37 rbx-97-n7 Oct 9 20:36:37 %KERN-2-SYSTEM_MSG: [4044331.427640] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:36:37 rbx-97-n7 Oct 9 20:36:37 %KERN-2-SYSTEM_MSG: [4044331.427687] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:36:49 rbx-97-n7 Oct 9 20:36:49 %KERN-2-SYSTEM_MSG: [4044343.195279] [0/252:am:am-high-pri-] Need wild send recovery - kernel
2012 Oct 9 20:37:05 rbx-97-n7 Oct 9 20:37:04 %KERN-2-SYSTEM_MSG: [4044358.052701] [sap 221][pid 5941][comm:l2fm] QFULL drop notify posted - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289725] mts_is_q_space_available_new():1533:Total mtsbuf size 23789950 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289738] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=242659(23789852), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289745] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289783] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289800] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289864] node=4 sap=221 rq=242659(23789852) lq=0(0) pq=1(98) nq=0(0) sq=0(0) buf_in_transit=2405220, bytes_in_transit=128045725 - kernel
2012 Oct 9 20:37:12 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289892] node=4 sap=337 rq=599(120998) lq=0(0) pq=0(0) nq=31(6262) sq=0(0) buf_in_transit=0, bytes_in_transit=0 - kernel
2012 Oct 9 20:37:13 rbx-97-n7 Oct 9 20:37:11 %KERN-2-SYSTEM_MSG: [4044365.289915] node=4 sap=242 rq=34763(4796634) lq=0(0) pq=0(0) nq=11(1518) sq=0(0) buf_in_transit=0, bytes_in_transit=0 - kernel
2012 Oct 9 20:37:45 rbx-97-n7 Oct 9 20:37:45 %KERN-2-SYSTEM_MSG: [4044399.520767] mts_is_q_space_available_new():1533:Total mtsbuf size 21374744 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:37:45 rbx-97-n7 Oct 9 20:37:45 %KERN-2-SYSTEM_MSG: [4044399.520794] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=218030(21374646), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:37:45 rbx-97-n7 Oct 9 20:37:45 %KERN-2-SYSTEM_MSG: [4044399.520801] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:37:45 rbx-97-n7 Oct 9 20:37:45 %KERN-2-SYSTEM_MSG: [4044399.520836] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:37:45 rbx-97-n7 Oct 9 20:37:45 %KERN-2-SYSTEM_MSG: [4044399.521279] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:38:05 rbx-97-n7 Oct 9 20:38:04 %KERN-2-SYSTEM_MSG: [4044418.067478] [sap 221][pid 5941][comm:l2fm] QFULL drop notify posted - kernel
2012 Oct 9 20:38:23 rbx-97-n7 Oct 9 20:38:22 %KERN-2-SYSTEM_MSG: [4044436.709151] mts_is_q_space_available_new():1533:Total mtsbuf size 19119942 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:38:23 rbx-97-n7 Oct 9 20:38:22 %KERN-2-SYSTEM_MSG: [4044436.709176] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=195055(19119844), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:38:23 rbx-97-n7 Oct 9 20:38:22 %KERN-2-SYSTEM_MSG: [4044436.709183] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:38:23 rbx-97-n7 Oct 9 20:38:22 %KERN-2-SYSTEM_MSG: [4044436.709212] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:38:23 rbx-97-n7 Oct 9 20:38:22 %KERN-2-SYSTEM_MSG: [4044436.709217] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:38:26 rbx-97-n7 %ARP-3-MTS_SEND: arp [5514] Failed to send add adjacency message to high_pri AM queue: Device or resource busy
2012 Oct 9 20:38:57 rbx-97-n7 Oct 9 20:38:56 %KERN-2-SYSTEM_MSG: [4044470.699085] mts_is_q_space_available_new():1533:Total mtsbuf size 18882514 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:38:57 rbx-97-n7 Oct 9 20:38:56 %KERN-2-SYSTEM_MSG: [4044470.699111] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=192628(18882368), lq=0(0), pq=1(98), nq=1(48), sq=0(0), fa
t: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:38:57 rbx-97-n7 Oct 9 20:38:56 %KERN-2-SYSTEM_MSG: [4044470.699118] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:38:57 rbx-97-n7 Oct 9 20:38:56 %KERN-2-SYSTEM_MSG: [4044470.699149] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:38:57 rbx-97-n7 Oct 9 20:38:56 %KERN-2-SYSTEM_MSG: [4044470.703916] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:38:59 rbx-97-n7 %ARP-3-MTS_SEND: arp [5514] Failed to send add adjacency message to high_pri AM queue: Device or resource busy
2012 Oct 9 20:39:04 rbx-97-n7 Oct 9 20:39:04 %KERN-2-SYSTEM_MSG: [4044478.072703] [sap 221][pid 5941][comm:l2fm] QFULL drop notify posted - kernel
2012 Oct 9 20:39:09 rbx-97-n7 %ARP-3-MTS_SEND: arp [5514] Failed to send add adjacency message to high_pri AM queue: Device or resource busy
2012 Oct 9 20:39:27 rbx-97-n7 last message repeated 1 time
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026136] mts_is_q_space_available_new():1533:Total mtsbuf size 17772630 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026164] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=181274(17772532), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026171] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026199] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026204] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:39:27 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026216] node=4 sap=1 rq=3350(204296) lq=0(0) pq=0(0) nq=0(0) sq=0(0) buf_in_transit=-3, bytes_in_transit=-348 - kernel
2012 Oct 9 20:39:28 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026287] node=4 sap=221 rq=181274(17772532) lq=0(0) pq=1(98) nq=0(0) sq=0(0) buf_in_transit=2787711, bytes_in_transit=146405456 - kernel
2012 Oct 9 20:39:28 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026316] node=4 sap=337 rq=571(115342) lq=0(0) pq=0(0) nq=20(4040) sq=0(0) buf_in_transit=0, bytes_in_transit=0 - kernel
2012 Oct 9 20:39:28 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026342] node=4 sap=252 rq=4954(237792) lq=0(0) pq=28(1344) nq=0(0) sq=0(0) buf_in_transit=2309094, bytes_in_transit=279066578 - kernel
2012 Oct 9 20:39:28 rbx-97-n7 Oct 9 20:39:27 %KERN-2-SYSTEM_MSG: [4044501.026349] node=4 sap=242 rq=63829(8804832) lq=0(0) pq=0(0) nq=11(1518) sq=0(0) buf_in_transit=0, bytes_in_transit=0 - kernel
2012 Oct 9 20:39:51 rbx-97-n7 %ARP-3-MTS_SEND: arp [5514] Failed to send add adjacency message to high_pri AM queue: Device or resource busy
2012 Oct 9 20:39:57 rbx-97-n7 Oct 9 20:39:57 %KERN-2-SYSTEM_MSG: [4044531.290594] mts_is_q_space_available_new():1533:Total mtsbuf size 18178870 for sap 221, exceeds limit 30 perc of 100663296 - kernel
2012 Oct 9 20:39:57 rbx-97-n7 Oct 9 20:39:57 %KERN-2-SYSTEM_MSG: [4044531.290617] mts_is_q_space_available_new(): NO SPACE - node=4, sap=221, uuid=410, pid=5941, sap_opt = 0x1, hdr_opt = 0x0, rq=185412(18178772), lq=0(0), pq=1(98), nq=0(0), sq=0(0), fas
: rq=0, lq=0, pq=0, nq=0, sq=0 - kernel
2012 Oct 9 20:39:57 rbx-97-n7 Oct 9 20:39:57 %KERN-2-SYSTEM_MSG: [4044531.290624] mts_print_longest_queue_state: opcode counts for first and last 50 messages in recv_q of sap 221: - kernel
2012 Oct 9 20:39:57 rbx-97-n7 Oct 9 20:39:57 %KERN-2-SYSTEM_MSG: [4044531.290668] mts_print_msg_opcode_in_queue: opcode 21553 - 100 messages - kernel
2012 Oct 9 20:39:57 rbx-97-n7 Oct 9 20:39:57 %KERN-2-SYSTEM_MSG: [4044531.290674] mts_do_msg_input() failing since no space available in 221 (src_sap = 221, opc = 21553) - kernel
2012 Oct 9 20:40:01 rbx-97-n7 %ARP-3-MTS_SEND: arp [5514] Failed to send add adjacency message to high_pri AM queue: Device or resource busy
2012 Oct 9 20:40:05 rbx-97-n7 Oct 9 20:40:04 %KERN-2-SYSTEM_MSG: [4044538.082651] [sap 221][pid 5941][comm:l2fm] QFULL drop notify posted - kernel
2012 Oct 9 20:40:05 rbx-97-n7 Oct 9 20:40:04 %KERN-2-SYSTEM_MSG: [4044538.082899] [sap 221][pid 5941][comm:l2fm] sap recovering failed and so Killed - kernel
2012 Oct 9 20:40:05 rbx-97-n7 %SYSMGR-2-SERVICE_CRASHED: Service \"l2fm\" (PID 5941) hasn't caught signal 6 (core will be saved).
2012 Oct 9 20:40:05 rbx-97-n7 %SYSMGR-3-SERVICE_TERMINATED: Service \"l2fm\" (PID 443) has finished with error code SYSMGR_EXITCODE_USERDEF (64).
2012 Oct 9 20:40:06 rbx-97-n7 %SYSMGR-3-SERVICE_TERMINATED: Service \"l2fm\" (PID 447) has finished with error code SYSMGR_EXITCODE_USERDEF (64).
2012 Oct 9 20:40:07 rbx-97-n7 %USER-3-SYSTEM_MSG: <> Handshake with System Manager failed for service \"l2fm\" (PID 450): Device or resource busy (16). - l2fm
2012 Oct 9 20:40:06 rbx-97-n7 %SYSMGR-3-SERVICE_TERMINATED: Service \"l2fm\" (PID 450) has finished with error code SYSMGR_EXITCODE_SYSERR (1).
2012 Oct 9 20:40:06 rbx-97-n7 %SYSMGR-2-SYSMGR_AUTOCOLLECT_TECH_SUPPORT_LOG: This supervisor will temporarily remain online in order to collect show tech-support. This behavior is configurable via 'system [no] auto-collect tech-support'. Collected inform
tion in /bootflash/hap_reset_show_tech.gz.
2012 Oct 9 20:40:07 rbx-97-n7 Oct 9 20:40:07 %KERN-2-SYSTEM_MSG: [4043794.793982] Switchover started by redundancy driver - kernel
2012 Oct 9 20:40:07 rbx-97-n7 %SYSMGR-2-HASWITCHOVER_PRE_START: This supervisor is becoming active (pre-start phase).
2012 Oct 9 20:40:07 rbx-97-n7 %SYSMGR-2-HASWITCHOVER_START: Supervisor 10 is becoming active.
2012 Oct 9 20:40:09 rbx-97-n7 %SYSMGR-2-SWITCHOVER_OVER: Switchover completed.
2012 Oct 9 20:40:09 rbx-97-n7 %PIXM-3-PIXM_SYSLOG_MESSAGE_TYPE_ERR: Process:VDC-1-pixm.Please collect show tech pixm-all, show tech pixmc-all .Non-transactional PIXM Error. Error Type:0x23.PC MBR_DATA present with rid: 0x16000013 memb_cnt: 0 p_pc_node: 0
ac205f4!
2012 Oct 9 20:40:09 rbx-97-n7 %VDC_MGR-5-VDC_MODULETYPE: vdc_mgr: Module type changed to m1 f1 m1xl m2xl
2012 Oct 9 20:40:11 rbx-97-n7 %CALLHOME-2-EVENT: SUP_FAILURE


Date: 2012-10-09 18:43:31 UTC
L'une des 2 SUP s'est rebooté, probablement à cause
du probleme. On va forcer le redemarrage de la
2eme sup dés que la 1ere est UP.

rbx-97-n7# sh system redundancy status
Redundancy mode
---------------
administrative: HA
operational: None

This supervisor (sup-2)
-----------------------
Redundancy state: Active
Supervisor state: Active
Internal state: Active with no standby

Other supervisor (sup-1)
------------------------
Redundancy state: Offline
Posted Oct 09, 2012 - 18:40 UTC