bhs-s6-6k
Scheduled Maintenance Report for Network & Infrastructure
Completed
Nous redémarrons le routeur afin d'effacer l'exception FIB TCAM présent sur la SUP du routeur.

Update(s):

Date: 2013-01-25 11:21:05 UTC
Done.

L’exception n'est plus présente :

bhs-s6-6k#show platform hardware cef exception status
Current IPv4 FIB exception state = FALSE
Current IPv6 FIB exception state = FALSE
Current MPLS FIB exception state = FALSE
Current EoM/VPLS FIB TCAM exception state = FALSE

bhs-s6-6k#show platform hardware cef tcam keys exception
Priorities in exception:
Class ID Pri (>=) Max Key-Cnt Pri-Cnt
IPv4 0 35 35 0
IPv4-Mcast 1 68 68 0
MPLS 2 17 17 0
EOMPLS 3 19 19 0
MPLS-VPN 4 9 9 0
Diags 5 5 5 0
IPv6-Local 6 259 259 0
IPv6-Mcast 7 261 261 0
IPv6-Global 8 259 259 0
VPLSv4-Mcast 9 69 69 0
VPLSv6-Mcast 10 261 261 0

Keys in each Pri in exception:
Class ID Pri XCP Pri-Cnt
Posted Jan 25, 2013 - 10:42 UTC
This scheduled maintenance affected: Infrastructure || BHS (BHS1, BHS2, BHS3, BHS4, BHS5, BHS6, BHS7).